HomeMy WebLinkAboutBoiler #2 Repairs/ReplacementMay 11, 2017 CITY OF WATERLOO, IOWA WASTE MANAGEMENT SERVICES DEPARTMENT 3505 Easton Ave. • Waterloo, IA 50702 • (319) 291-4553 To: Michelle Weidner From: Steve Hoambrecker Steve Hoambrecker, Director Michelle, we are attempting to reach a final resolve regarding the repairs -replacement of boiler #2 for the digester complex. Originally in March 2017 we requested and received permission to make repairs for the amount of $17,980.52 via a contract with Brecke. During the repairs, Brecke discovered conditions that concluded that the boiler could not cost effectively be repaired. At that point we decided to stop work on the existing contract. The have submitted the cost of worked to date of $9,645.54, leaving a total of $8.344.98 on the original contract. We have received a quoted price to purchase anew boiler in the amount of $51,250 from C.H. McGuiness Co., Inc. and a cost of $25, 246.98. I have prepared a pre-auth for the boiler replacement of $51,250 for Monday 5-15-17 agenda. In addition I would like to have a 2nd pre- auth for the labor installation of $16,911.92 as well, (this was obtained from the reducing the remaining $8,334.98 from the quoted price of $25, 246.98) I have included in the table below a calculation of related costs and expected year end projected costs calculations: Boiler #2 Repairs- Replacement Associated Costs Original price to make boiler #2 repairs $17,980.52 Amount spent $9,645.54 Amount remaining $8,334.98 Contract to replace/install new boiler $25,246.90 Adjusted price w remaining from original $16,911.92 Price of new boiler $51,250.00 Total new adjusted price complete w original and adjusted new $77,807.46 Amount of requested in yr end expected expenditure $75,000.00 City Clerk Use Only Finance Committee Approval Date City of Waterloo Expenditure Pre -Authorization Request Form The Finance Committee of the City Council is hereby requested to authorize the following purchase or expenditure submitted by the Sewer $ 51,250.00 Department to expend plus est. shipping costs of $ to pay for or purchase In March 2017 an original pre-auth was granted to have Brecke make repairs to boiler #2 During repairs it was decided the boiler was beyond repair & needed to be replaced. This purchase or expenditure is being made because: Boiler is leaking inside causing boiler to be inoperable and is critical to operations of the digester system. (This cost is to purchase the new boiler) Vendor selected for this purchase: Brecke Mechanical Contractors C Bids or written quotes were taken on this purchase, as follows: C Bids or quotes were not taken on this purchase because: Brecke Mechanical Contractors is rep. for repair and replacement service on boiler. Prior Committee Actions (Dates): Please check the following box(es) as appropriate to describe the funding for this expense: General Fund Road Use Tax I I Sewer n Sanitation n Bonds Federal/other grants Other (specify) This expenditure is to be coded to the following budget line -item: 520-14-5200-2119 (Fund - Department - Activity - Account Number) (Project Code) in which the budgeted amount is $ 100,000.00 and the current available balance is Respegjfully s bmitted, inat rs.ep . Head or Designee) K:\shared goodies\forms\rplacement boiler2 (Mar 2010) $ 87,480.00 Srr7 7 Date (Signature Finance Dept. Review) Date PROCESS & HTO FIRETUBE BOILERS WATERTUHE BOILERS CAST IRON BOILERS ELECTRIC BOILERS ELECTRIC WATER HEATERS DEAREATOR UNITS CONDSENSATE - BOILER FEED SYSTEMS OIL -GAS & GAS -OIL BURNERS To Mr. Brian Rath C. H. McGUINESS CO., INC. www.chmcguiness.com INDUSTRIAL & COMMERCIAL HEATING EQUIPMENT 1637 EAST 17TH STREET DES MOINES, IOWA 50316 PH: 515-262-5609 FAX: 515-262-5579 WATTS: 1-800-362-2256 City of Waterloo 715 Mulberry Waterloo, Iowa 50703 n 1535 WEST 15TH STREET DAVENPORT, IOWA 52804 PH: 563-323-0204 FAX: 563-323-1318 Date April 26, 2017 BOILER -BURNER ACCESSORIES FIREYE COMBUSTION CONTROLS HONEYWELL- GENERAL CONTROLS BOILER WELDING - RETUBING REFRACTORY MATERIALS STORAGE TANKS - HEAT EXCHANGERS INFRA -RED HEATING COMM. WATER HEATERS Name of Job Wastewater Treatment Plant Location Quote #17-0426-03 Page 1 of 4 POR IMMEDIATE ACCEPTANCE AND SUBJECT TO CHANGE WITHOUT NOTICE, ALL AGREEMENTS SUBJECT TO STRIKES, ACCIDENTS AND OTHER CAUSES BEYOND OUR CONTROL. 000DS WHICH HAVE PROVED DEFECTIVE IN MANUFACTURE WILL BE DUPLICATED BUT NO CLAIM FOR LABOR OR DAMAGE WILL BE ALLOWED. WE ARE PLEASED TO QUOTE YOU ON THE FOLLOWING MATERIAL FOR THE ABOVE JOB: PRICE One [1] Burnham 4FHW-563 three pass firebox type 30 psi water boiler with an input of 4713 MBH and complete with: CSD -1 code accessories ASME relief valve Pressure and temperature gauge Operating control Low fire hold aquastat High limit control with manual reset Modulating control McDonnell -Miller #63M low water cutoff with manual res McDonnell -Miller #TC -4 test -n -check valves Steel skid base Insulated metal jacket Top smoke outlet with quadrant damper Stack thermometer Front and rear tube access doors Rear access opening with observation port 3" x 4" handhole cleanout openings ACCEPTED C.H. McGui By B r - Nat) a Tf( tk -) - %-i-o $) taa - "'"ij s - g" via -ewe{, o., Inc. PROCESS & HTO FIRETUBE BOILERS WATERTUBE BOILERS CAST IRON BOILERS ELECTRIC BOILERS ELECTRIC WATER HEATERS DEAREATOR UNITS CONDSENSATE - BOILER FEED SYSTEMS OIL -GAS & GAS -OIL BURNERS To Mr. Brian Rath C. H. McGUINESS CO., INC. www.chmcguiness.com INDUSTRIAL & COMMERCIAL HEATING EQUIPMENT g1637 EAST 17TH STREET DES MOINES, IOWA 50316 PH: 515-262-5609 FAX: 515-262-5579 WATrs:1-800-362-2256 City of Waterloo 715 Mulberry Waterloo, Iowa 50703 BOILER -BURNER ACCESSORIES FIREYE COMBUSTION CONTROLS HONEYWELL - GENERAL CONTROLS BOILER WELDING - RETUBING REFRACTORY MATERIALS STORAGE TANKS - HEAT EXCHANGERS LI 1535 WEST 15TH STREET INFRARED HEATING DAVENPORT, IOWA 52804 COMM. WATER HEATERS PH: 563-323-0204 FAX: 563-323-1318 Date April 26, 2017 Name of Job Wastewater Treatment Plant Location Quote #17-0426-03 Page 2 of 4 FOR IMMEDIATE ACCEPTANCE AND SUBJECT WI CHANGE WITHOUT NOTICE. ALL AGREEMENTS SUBJECT TO STRIKES, ACCIDENTS AND OTHER CAUSES BEYOND OUR CONTROL. GOODS WHICH HAVE PROVED DEFECTIVE IN MANUFACTURE WILL BE DUPLICATED BUT NO CLAIM FOR LABOR OR DAMAGE WILL BE ALLOWED. WE ARE PLEASED TO •UOTE YOU ON THE FOLLOWING MATERIAL FOR THE ABOVE JOB: PRICE Lifting eyes Power Flame forced draft natural gas/digester gas burner Current: 460/60/3 120 volt control transformer Gas -electric ignition system Pilot magnetic valve, regulator and gas cock Motor magnetic starter Modulating firing sequence with low fire start Honeywell RM7800L combustion control Pre and post purge U.V. flame scanner Prewired panel cabinet with switch fuse, auto -fuel changeover system, gas/gas selector switch, local -remote switch and [9] indicating lights Manual -automatic firing rate switch Modulating control motor and linkage ACCEPTED C.H. McGuines •. Inc. By By PROCESS & HTO FIRETUBE BOILERS WATERTUBE BOILERS CAST IRON BOILERS ELECTRIC BOILERS ELECTRIC WATER HEATERS DEAREATOR UNITS CONDSENSATE • BOILER FEED SYSTEMS OIL -GAS & GAS -OIL BURNERS To Mr. Brian Rath C. H. McGUINESS CO., INC. www.chmcguiness.com INDUSTRIAL & COMMERCIAL HEATING EQUIPMENT 1637 EAST 17TH STREET DES MOINES, IOWA 50316 PH: 515-262-5609 FAX: 515-262-5579 WATrs: 1-800-362-2256 City of Waterloo 715 Mulberry Ell 1535 WEST 15TH STREET DAVENPORT, IOWA 52804 PH: 563-323-0204 FAx: 563-323-1318 Date April 26, 2017 BOILER -BURNER ACCESSORIES FIREYE COMBUSTION CONTROLS HONEYWELL - GENERAL CONTROLS BOILER WELDING - RETUBINO REFRACTORY MATERIALS STORAGE TANKS - HEAT EXCHANGERS INFRA -RED HEATING COMM. WATER HEATERS Name of Job Wastewater Treatment Plant Location Waterloo, Iowa 50703 Quote #17-0426-03 Page 3 of 4 FOR IMMEDIATE ACCEPTANCE AND SUBJECT TO CHANGE WITHOUT NOTICE. ALL AGREEMENT'S SUBJECT TO STRIKES, ACCIDENTS AND OTHER CAUSES BEYOND OUR CONTROL GOODS WHICH HAVE PROVED DEFECTIVE IN MANUFACTURE WILL BE DUPLICATED BUT NO CLAIM FOR LABOR OR DAMAGE WILL BE ALLOWED. WE ARE PLEASED TO QUOTE YOU ON THE FOLLOWING MATERIAL FOR THE ABOVE JOB: PRICE FM natural gas control train consisting of: butterfly volume control valve, motorized operating gas valve, gas pressure regulator, motorized safety gas valve, high and low gas pressure switches and main gas shutoff cock FM digester gas control train consisting of: butterfly volume control valve, motorized operating gas valve, gas pressure regulator, motorized safety gas valve, high and low gas pressure switches, gas strainer and main gas shutoff cock Airflow safety switch Manifold gas gauges Freight allowed to jobsite [9300#] Startup and review with operating personnel TOTAL ACCEPTED C.H. McGuiness By By $51,250.00 PROCESS & RIG FIRETUBE BOILERS WATERTUBE BOILERS CAST IRON BOILERS ELECTRIC BOILERS ELECTRIC WATER HEATERS DEA REATOR UNITS CONDSENSATE - BOILER FEED SYSTEMS OIL -GAS & GAS -OIL BURNERS To Mr. Brian Rath C. H. McGUINESS CO., INC. www.chmcguiness.com INDUSTRIAL & COMMERCIAL HEATING EQUIPMENT 0 1637 EAST 17m STREET DES MOINES, IowA 50316 PH: 515-262-5609 FAX: 515-262-5579 WATTS: 1-800-362-2256 City of Waterloo 715 Mulberry 0 1535 WEST 15TH STREET DAVENPORT, IOWA 52804 PH: 563-323-0204 FAX: 563-323-1318 Date April 26, 2017 BOILER -BURNER ACCESSORIES FIREYE COMBUSTION CONTROLS HONEYWELL - GENERAL CONTROLS BOILER WELDING - RETUBING REFRACTORY MATERIALS STORAGE TANKS - HEAT EXCHANGERS INFRA -RED HEATING COMM. WATER HEATERS Name of Job Wastewater Treatment Plant Location Waterloo, Iowa 50703 Quote #17-0426-03 Page 4 of 4 FOR IMMEDIATE ACCEPTANCE AND SUBJECT TO CHANGE WITHOUT NCMCE. ALL AGREEMENTS SUBJECT TO STRIKES, ACCIDENTS AND OTHER CAUSES BEYOND OUR CONTROL GOODS WHICH HAVE PROVED DEFECTIVE IN MANUFACTURE WILL BE DUPLICATED BUT NO CLAIM FOR LABOR OR DAMAGE WILL BE ALLOWED. WE ARE PLEASED TO QUOTE YOU ON THE FOLLOWING MATERIAL FOR THE ABOVE JOB: PRICE NOTES: (1) Unloading and installation by others. (2) Boiler will be shipped with burner, water trim and gas trains loose. Installing contractor will be responsible for mounting and wiring of these items. (3) Natural gas control train is sized for 11"-14" w.c. inlet gas pressure. Digester gas train is sized for 22" w.c. inlet gas pressure. (4) No sales tax is included, it will be added if applicable. (5) Proposal is good for 30 days, subject to surcharges from the manufacturer. (6) Payment terms are Net 30 days. ACCEPTED C.H. McGuine By By BURNHAM° Corn DCfD®DCd& O flkDDOstrz LEGEND CONNECTIONS A = 10' FLANGED SUPPLY (150#) B = 4' RETURN C = 3" a 4" HANDHOLE D = P WATER COLUMN E = 3/4" AQUAETAT F = i -i/2" SURFACE BLOWOFF/ WASHOUT G = 1/2" TEMPERATURE GAUGE H = 2" SAFETY/RELIEF VALVE 7 = 1" AUXILIARY CONNECTION K = 15" NOMINAL FLUE DLAMETER RATINGS AND DATA Shell Diameter : 51�" Heating Surface - Sq. Ft. Fireside - 563 Waterside - 622 Firetubes Number - 128 Diameter - 2" 0.D. Furnace Volume (Cubic Feet) - 69.3 Water Content Steam - 664 Gal. (U.S.) Water - 800 Col. (U.S.) Approximate Weight (Lb.) Dry - 9300 Wet (Steam) - 14815 Wet (Water) - 15975 57 57 NOTE . TUBE PULL SPACE LEGEND BS = BOTH SIDES RS = RIGHT SIDE L5 = LEFT SIDE FB = FRONT OF BOILER RB = REAR OF BOILER REAR OUTLET. STANDARD TOP OUTLET, OPTIONAL JRNER EQUIPMENT Y EXTEND BEYOND OILER DIMENSIONS C (FB) 3 135 ERC61WAY6 MST to PONCE VENOUS !MICE ALL CONMEOSONs ML SIMMS> UNLESS OMERWSC SPOOF= TNM DOCUMENT S K7 e6 C taODaw. INFORWTON ?RICH IS ISE P OPatrr OF WRNIVL COMMERCIAL nSS oo Uun.r !AT NOT SE REPRCOYCc. TRVeRTRED OM=pt, SMMOUT 'RR VMELY PERMISSION OF mE OWNER. MODEL 4F-563 oar 2015 TS -3-15-2 I28 OVER.._O ..._... OVER COND20LS yrs) am N.W.L �' CS '(6 TO BOTTOM PLATE OF SMOKEBOX AM B 72 41T4 FURNACE rSU c 21 ON " : .., ,, r —L 57 57 NOTE . TUBE PULL SPACE LEGEND BS = BOTH SIDES RS = RIGHT SIDE L5 = LEFT SIDE FB = FRONT OF BOILER RB = REAR OF BOILER REAR OUTLET. STANDARD TOP OUTLET, OPTIONAL JRNER EQUIPMENT Y EXTEND BEYOND OILER DIMENSIONS C (FB) 3 135 ERC61WAY6 MST to PONCE VENOUS !MICE ALL CONMEOSONs ML SIMMS> UNLESS OMERWSC SPOOF= TNM DOCUMENT S K7 e6 C taODaw. INFORWTON ?RICH IS ISE P OPatrr OF WRNIVL COMMERCIAL nSS oo Uun.r !AT NOT SE REPRCOYCc. TRVeRTRED OM=pt, SMMOUT 'RR VMELY PERMISSION OF mE OWNER. MODEL 4F-563 oar 2015 TS -3-15-2