HomeMy WebLinkAboutBoiler #2 Repairs/ReplacementMay 11, 2017
CITY OF WATERLOO, IOWA
WASTE MANAGEMENT SERVICES DEPARTMENT
3505 Easton Ave. • Waterloo, IA 50702 • (319) 291-4553
To: Michelle Weidner
From: Steve Hoambrecker
Steve Hoambrecker, Director
Michelle, we are attempting to reach a final resolve regarding the repairs -replacement of boiler
#2 for the digester complex. Originally in March 2017 we requested and received permission to
make repairs for the amount of $17,980.52 via a contract with Brecke. During the repairs,
Brecke discovered conditions that concluded that the boiler could not cost effectively be
repaired. At that point we decided to stop work on the existing contract. The have submitted
the cost of worked to date of $9,645.54, leaving a total of $8.344.98 on the original contract.
We have received a quoted price to purchase anew boiler in the amount of $51,250 from C.H.
McGuiness Co., Inc. and a cost of $25, 246.98. I have prepared a pre-auth for the boiler
replacement of $51,250 for Monday 5-15-17 agenda. In addition I would like to have a 2nd pre-
auth for the labor installation of $16,911.92 as well, (this was obtained from the reducing the
remaining $8,334.98 from the quoted price of $25, 246.98)
I have included in the table below a calculation of related costs and expected year end
projected costs calculations:
Boiler #2 Repairs- Replacement Associated Costs
Original price to make boiler #2 repairs
$17,980.52
Amount spent
$9,645.54
Amount remaining
$8,334.98
Contract to replace/install new boiler
$25,246.90
Adjusted price w remaining from original
$16,911.92
Price of new boiler
$51,250.00
Total new adjusted price complete w original and adjusted
new
$77,807.46
Amount of requested in yr end expected expenditure
$75,000.00
City Clerk Use Only
Finance Committee
Approval Date
City of Waterloo
Expenditure Pre -Authorization Request Form
The Finance Committee of the City Council is hereby requested to authorize the following
purchase or expenditure submitted by the Sewer
$ 51,250.00
Department to expend
plus est. shipping costs of $ to pay for or purchase
In March 2017 an original pre-auth was granted to have Brecke make repairs to boiler #2
During repairs it was decided the boiler was beyond repair & needed to be replaced.
This purchase or expenditure is being made because:
Boiler is leaking inside causing boiler to be inoperable and is critical to operations of the
digester system. (This cost is to purchase the new boiler)
Vendor selected for this purchase: Brecke Mechanical Contractors
C Bids or written quotes were taken on this purchase, as follows:
C Bids or quotes were not taken on this purchase because:
Brecke Mechanical Contractors is rep. for repair and replacement service on boiler.
Prior Committee Actions (Dates):
Please check the following box(es) as appropriate to describe the funding for this expense:
General Fund Road Use Tax I I Sewer n Sanitation
n Bonds Federal/other grants Other (specify)
This expenditure is to be coded to the following budget line -item:
520-14-5200-2119
(Fund - Department - Activity - Account Number)
(Project Code)
in which the budgeted amount is $ 100,000.00
and the current available balance is
Respegjfully s bmitted,
inat rs.ep . Head or Designee)
K:\shared goodies\forms\rplacement boiler2 (Mar 2010)
$ 87,480.00
Srr7 7
Date (Signature Finance Dept. Review) Date
PROCESS & HTO FIRETUBE BOILERS
WATERTUHE BOILERS
CAST IRON BOILERS
ELECTRIC BOILERS
ELECTRIC WATER HEATERS
DEAREATOR UNITS
CONDSENSATE - BOILER FEED SYSTEMS
OIL -GAS & GAS -OIL BURNERS
To Mr. Brian Rath
C. H. McGUINESS CO., INC.
www.chmcguiness.com
INDUSTRIAL & COMMERCIAL HEATING EQUIPMENT
1637 EAST 17TH STREET
DES MOINES, IOWA 50316
PH: 515-262-5609
FAX: 515-262-5579
WATTS: 1-800-362-2256
City of Waterloo
715 Mulberry
Waterloo, Iowa 50703
n 1535 WEST 15TH STREET
DAVENPORT, IOWA 52804
PH: 563-323-0204
FAX: 563-323-1318
Date April 26, 2017
BOILER -BURNER ACCESSORIES
FIREYE COMBUSTION CONTROLS
HONEYWELL- GENERAL CONTROLS
BOILER WELDING - RETUBING
REFRACTORY MATERIALS
STORAGE TANKS - HEAT EXCHANGERS
INFRA -RED HEATING
COMM. WATER HEATERS
Name of Job Wastewater Treatment Plant
Location
Quote #17-0426-03
Page 1 of 4
POR IMMEDIATE ACCEPTANCE AND SUBJECT TO CHANGE WITHOUT NOTICE, ALL AGREEMENTS SUBJECT TO STRIKES, ACCIDENTS AND OTHER CAUSES BEYOND OUR
CONTROL. 000DS WHICH HAVE PROVED DEFECTIVE IN MANUFACTURE WILL BE DUPLICATED BUT NO CLAIM FOR LABOR OR DAMAGE WILL BE ALLOWED.
WE ARE PLEASED TO QUOTE YOU ON THE FOLLOWING MATERIAL FOR THE ABOVE JOB:
PRICE
One [1] Burnham 4FHW-563 three pass firebox type 30 psi water boiler
with an input of 4713 MBH and complete with:
CSD -1 code accessories
ASME relief valve
Pressure and temperature gauge
Operating control
Low fire hold aquastat
High limit control with manual reset
Modulating control
McDonnell -Miller #63M low water cutoff with manual res
McDonnell -Miller #TC -4 test -n -check valves
Steel skid base
Insulated metal jacket
Top smoke outlet with quadrant damper
Stack thermometer
Front and rear tube access doors
Rear access opening with observation port
3" x 4" handhole cleanout openings
ACCEPTED C.H. McGui
By B
r
- Nat) a
Tf(
tk -)
- %-i-o $) taa - "'"ij s -
g" via -ewe{,
o., Inc.
PROCESS & HTO FIRETUBE BOILERS
WATERTUBE BOILERS
CAST IRON BOILERS
ELECTRIC BOILERS
ELECTRIC WATER HEATERS
DEAREATOR UNITS
CONDSENSATE - BOILER FEED SYSTEMS
OIL -GAS & GAS -OIL BURNERS
To Mr. Brian Rath
C. H. McGUINESS CO., INC.
www.chmcguiness.com
INDUSTRIAL & COMMERCIAL HEATING EQUIPMENT
g1637 EAST 17TH STREET
DES MOINES, IOWA 50316
PH: 515-262-5609
FAX: 515-262-5579
WATrs:1-800-362-2256
City of Waterloo
715 Mulberry
Waterloo, Iowa 50703
BOILER -BURNER ACCESSORIES
FIREYE COMBUSTION CONTROLS
HONEYWELL - GENERAL CONTROLS
BOILER WELDING - RETUBING
REFRACTORY MATERIALS
STORAGE TANKS - HEAT EXCHANGERS
LI 1535 WEST 15TH STREET INFRARED HEATING
DAVENPORT, IOWA 52804 COMM. WATER HEATERS
PH: 563-323-0204
FAX: 563-323-1318
Date April 26, 2017
Name of Job Wastewater Treatment Plant
Location
Quote #17-0426-03 Page 2 of 4
FOR IMMEDIATE ACCEPTANCE AND SUBJECT WI CHANGE WITHOUT NOTICE. ALL AGREEMENTS SUBJECT TO STRIKES, ACCIDENTS AND OTHER CAUSES BEYOND OUR
CONTROL. GOODS WHICH HAVE PROVED DEFECTIVE IN MANUFACTURE WILL BE DUPLICATED BUT NO CLAIM FOR LABOR OR DAMAGE WILL BE ALLOWED.
WE ARE PLEASED TO •UOTE YOU ON THE FOLLOWING MATERIAL FOR THE ABOVE JOB:
PRICE
Lifting eyes
Power Flame forced draft natural gas/digester gas burner
Current: 460/60/3
120 volt control transformer
Gas -electric ignition system
Pilot magnetic valve, regulator and gas cock
Motor magnetic starter
Modulating firing sequence with low fire start
Honeywell RM7800L combustion control
Pre and post purge
U.V. flame scanner
Prewired panel cabinet with switch fuse, auto -fuel changeover system,
gas/gas selector switch, local -remote switch and [9] indicating lights
Manual -automatic firing rate switch
Modulating control motor and linkage
ACCEPTED C.H. McGuines •. Inc.
By By
PROCESS & HTO FIRETUBE BOILERS
WATERTUBE BOILERS
CAST IRON BOILERS
ELECTRIC BOILERS
ELECTRIC WATER HEATERS
DEAREATOR UNITS
CONDSENSATE • BOILER FEED SYSTEMS
OIL -GAS & GAS -OIL BURNERS
To Mr. Brian Rath
C. H. McGUINESS CO., INC.
www.chmcguiness.com
INDUSTRIAL & COMMERCIAL HEATING EQUIPMENT
1637 EAST 17TH STREET
DES MOINES, IOWA 50316
PH: 515-262-5609
FAX: 515-262-5579
WATrs: 1-800-362-2256
City of Waterloo
715 Mulberry
Ell 1535 WEST 15TH STREET
DAVENPORT, IOWA 52804
PH: 563-323-0204
FAx: 563-323-1318
Date April 26, 2017
BOILER -BURNER ACCESSORIES
FIREYE COMBUSTION CONTROLS
HONEYWELL - GENERAL CONTROLS
BOILER WELDING - RETUBINO
REFRACTORY MATERIALS
STORAGE TANKS - HEAT EXCHANGERS
INFRA -RED HEATING
COMM. WATER HEATERS
Name of Job Wastewater Treatment Plant
Location
Waterloo, Iowa 50703 Quote #17-0426-03
Page 3 of 4
FOR IMMEDIATE ACCEPTANCE AND SUBJECT TO CHANGE WITHOUT NOTICE. ALL AGREEMENT'S SUBJECT TO STRIKES, ACCIDENTS AND OTHER CAUSES BEYOND OUR
CONTROL GOODS WHICH HAVE PROVED DEFECTIVE IN MANUFACTURE WILL BE DUPLICATED BUT NO CLAIM FOR LABOR OR DAMAGE WILL BE ALLOWED.
WE ARE PLEASED TO QUOTE YOU ON THE FOLLOWING MATERIAL FOR THE ABOVE JOB:
PRICE
FM natural gas control train consisting of: butterfly volume control
valve, motorized operating gas valve, gas pressure regulator,
motorized safety gas valve, high and low gas pressure switches
and main gas shutoff cock
FM digester gas control train consisting of: butterfly volume control
valve, motorized operating gas valve, gas pressure regulator,
motorized safety gas valve, high and low gas pressure switches,
gas strainer and main gas shutoff cock
Airflow safety switch
Manifold gas gauges
Freight allowed to jobsite [9300#]
Startup and review with operating personnel
TOTAL
ACCEPTED C.H. McGuiness
By By
$51,250.00
PROCESS & RIG FIRETUBE BOILERS
WATERTUBE BOILERS
CAST IRON BOILERS
ELECTRIC BOILERS
ELECTRIC WATER HEATERS
DEA REATOR UNITS
CONDSENSATE - BOILER FEED SYSTEMS
OIL -GAS & GAS -OIL BURNERS
To Mr. Brian Rath
C. H. McGUINESS CO., INC.
www.chmcguiness.com
INDUSTRIAL & COMMERCIAL HEATING EQUIPMENT
0 1637 EAST 17m STREET
DES MOINES, IowA 50316
PH: 515-262-5609
FAX: 515-262-5579
WATTS: 1-800-362-2256
City of Waterloo
715 Mulberry
0 1535 WEST 15TH STREET
DAVENPORT, IOWA 52804
PH: 563-323-0204
FAX: 563-323-1318
Date April 26, 2017
BOILER -BURNER ACCESSORIES
FIREYE COMBUSTION CONTROLS
HONEYWELL - GENERAL CONTROLS
BOILER WELDING - RETUBING
REFRACTORY MATERIALS
STORAGE TANKS - HEAT EXCHANGERS
INFRA -RED HEATING
COMM. WATER HEATERS
Name of Job Wastewater Treatment Plant
Location
Waterloo, Iowa 50703 Quote #17-0426-03 Page 4 of 4
FOR IMMEDIATE ACCEPTANCE AND SUBJECT TO CHANGE WITHOUT NCMCE. ALL AGREEMENTS SUBJECT TO STRIKES, ACCIDENTS AND OTHER CAUSES BEYOND OUR
CONTROL GOODS WHICH HAVE PROVED DEFECTIVE IN MANUFACTURE WILL BE DUPLICATED BUT NO CLAIM FOR LABOR OR DAMAGE WILL BE ALLOWED.
WE ARE PLEASED TO QUOTE YOU ON THE FOLLOWING MATERIAL FOR THE ABOVE JOB:
PRICE
NOTES:
(1) Unloading and installation by others.
(2) Boiler will be shipped with burner, water trim and gas trains loose.
Installing contractor will be responsible for mounting and wiring of
these items.
(3) Natural gas control train is sized for 11"-14" w.c. inlet gas pressure.
Digester gas train is sized for 22" w.c. inlet gas pressure.
(4) No sales tax is included, it will be added if applicable.
(5) Proposal is good for 30 days, subject to surcharges from the
manufacturer.
(6) Payment terms are Net 30 days.
ACCEPTED C.H. McGuine
By By
BURNHAM°
Corn
DCfD®DCd& O flkDDOstrz
LEGEND CONNECTIONS
A = 10' FLANGED SUPPLY (150#)
B = 4' RETURN
C = 3" a 4" HANDHOLE
D = P WATER COLUMN
E = 3/4" AQUAETAT
F = i -i/2" SURFACE BLOWOFF/
WASHOUT
G = 1/2" TEMPERATURE GAUGE
H = 2" SAFETY/RELIEF VALVE
7 = 1" AUXILIARY CONNECTION
K = 15" NOMINAL FLUE DLAMETER
RATINGS AND DATA
Shell Diameter : 51�"
Heating Surface - Sq. Ft.
Fireside - 563
Waterside - 622
Firetubes
Number - 128
Diameter - 2" 0.D.
Furnace
Volume (Cubic Feet) - 69.3
Water Content
Steam - 664 Gal. (U.S.)
Water - 800 Col. (U.S.)
Approximate Weight (Lb.)
Dry - 9300
Wet (Steam) - 14815
Wet (Water) - 15975
57
57
NOTE .
TUBE PULL SPACE
LEGEND
BS = BOTH SIDES
RS = RIGHT SIDE
L5 = LEFT SIDE
FB = FRONT OF BOILER
RB = REAR OF BOILER
REAR OUTLET.
STANDARD
TOP OUTLET,
OPTIONAL
JRNER EQUIPMENT
Y EXTEND BEYOND
OILER DIMENSIONS
C
(FB)
3
135
ERC61WAY6 MST to PONCE VENOUS !MICE ALL CONMEOSONs ML SIMMS> UNLESS OMERWSC SPOOF=
TNM DOCUMENT S K7 e6 C taODaw. INFORWTON ?RICH IS ISE P OPatrr OF WRNIVL COMMERCIAL nSS oo Uun.r !AT NOT SE REPRCOYCc. TRVeRTRED OM=pt, SMMOUT 'RR VMELY PERMISSION OF mE OWNER.
MODEL 4F-563
oar 2015 TS -3-15-2
I28 OVER.._O ..._...
OVER COND20LS
yrs)
am
N.W.L
�'
CS
'(6
TO BOTTOM
PLATE OF
SMOKEBOX
AM
B
72
41T4
FURNACE
rSU
c
21 ON
"
: ..,
,,
r
—L
57
57
NOTE .
TUBE PULL SPACE
LEGEND
BS = BOTH SIDES
RS = RIGHT SIDE
L5 = LEFT SIDE
FB = FRONT OF BOILER
RB = REAR OF BOILER
REAR OUTLET.
STANDARD
TOP OUTLET,
OPTIONAL
JRNER EQUIPMENT
Y EXTEND BEYOND
OILER DIMENSIONS
C
(FB)
3
135
ERC61WAY6 MST to PONCE VENOUS !MICE ALL CONMEOSONs ML SIMMS> UNLESS OMERWSC SPOOF=
TNM DOCUMENT S K7 e6 C taODaw. INFORWTON ?RICH IS ISE P OPatrr OF WRNIVL COMMERCIAL nSS oo Uun.r !AT NOT SE REPRCOYCc. TRVeRTRED OM=pt, SMMOUT 'RR VMELY PERMISSION OF mE OWNER.
MODEL 4F-563
oar 2015 TS -3-15-2