HomeMy WebLinkAboutIowa Department of Transportaiton-5/6/2013IOWA DEPARTMENT OF NATURAL RESOURCES
Wastewater Disposal System Construction Permit
Application Fee Form
CASHIER'S USE ONLY
0945-542-N PDE -CP -0570
32-3202
Owner
Owner Name: City of Waterloo, Iowa
Address: 715 Mulberry Street
City, State, Zip: Waterloo, Iowa, 50703
Project Identification: No Name Creek Interceptor Sewer, City Contract No. 849
® $100 Fee enclosed
Please sign and return this form with a check or money order payable to "Iowa Department of Natural Resources".
Place it and the check or money order on top of other Construction Permit Application documents.
Effective beginning July 1, 2006, Applications for Construction Permits for wastewater disposal systems required by
Iowa Code 4556.173 and rules in Iowa Administrative Code 567 IAC 64, must be accompanied by the fee required by
Iowa Code 455B.197 and Iowa Administrative Code 567 IAC 64.16(3)"c".
The fee is $100 for each application, regardless of project size and project type including sanitary sewers, pump
stations, treatment units or a combination thereof. The fee shall be submitted with the certified engineering documents
necessary to apply for a construction permit (plans, specifications and related application schedules A, F, and G as well
as the appropriate schedules indentified on page 2 of Schedule A). The construction permitting process is initiated as
planning for construction begins. Planning coordination and submittal of preliminary engineering reports or facility
plans precedes submittal of technical documents necessary to constitute a construction permit application. The
application fee is not necessary when submitting a planning document but must accompany construction permit
application documents. A fee should accompany each permit application received on or after July 1, 2006.
Failure to submit a fee with the application may delay the processing of a construction permit. If you have any questions
regarding the application fee, please contact Donna Gomm at 515-281-8502 or Donna.Gomm@dnr.iowa.gov
Signature of Owner or Representative:
Printed Name: r
4\y
Telephone or email contact:
614-ta-P 10(46-1z
Mail to:
Iowa Department of Natural Resources
Wastewater Engineering Section
502 East 9th Street
Des Moines, IA 50319-0034
L:\work\projecfl60283855\400 Technical\420_Specs\60283855-No Name Creek Speaboc - Application Fee Form.doac
Exhibit 11A
Iowa Department of Natural Resources Wastewater Engineering Section
Construction Permit Application
SCHEDULE A, General Information
APPLICANT
ENGINEER
OWNER E-MAIL ADDRESS
City of Waterloo, IA larry.smith@waterloo-ia.org
FIRM E-MAIL ADDRESS
AECOM todd.allyn@aecom.com
ADDRESS
715 Mulberry Street, Waterloo, IA 50703
ADDRESS
500 SW 7th Street, Suite 301, Des Moines, Iowa 50309
REPRESENTATIVE TELEPHONE
Larry Smith 319-291-4553
PROJECT OFFICER TELEPHONE
Todd Allyn 515-323-7921
PROJECT IDENTIFICATION
No Name Creek Interceptor Sewer
City Contract No. 849
ESTIMATED
START DATE *
06/03/13
ESTIMATED COMPLETION DATE
08/30/13
PLEASE RESPOND TO ALL QUESTIONS YES NO
1. Has an engineering report, facilities plan or other information previously been submitted for this project? ❑>��
If Yes=>
PROJECT IDENTITY
DATE SUBMITTED
2. Does the project and construction permit application, as submitted, follow the recommendations, design
loadings, construction schedule, permit limits, and conclusions of the approved engineering report or facilities
If No=> Provide the design basis and technical information justifying all changes.
3. Are there three complete sets of plans and specifications accompanying this application?
For a minor gravity sewer extension within the meaning of 455B.183.3 Code of Iowa and Design Standard 11.1,
two complete sets will be adequate for expeditious approval. For more complex projects, three sets of plans and
specifications may be requested.
4. Are approved standard specifications a part of this application?
■
A
®
0
0
0
If Yes=>
APPROVED STANDARD SPECIFICATIONS OF
(municipality or firm)
SUDAS Specifications
DATE APPROVED
2012
5. Does each set of plans and specifications or engineering report accompanying this application contain a
"professional engineering seal" executed in conformance with 542B.16, Code of Iowa?
If No=> Processing will be delayed pending receipt of applicable design schedules and certified plans,
specifications or engineering report.
6. Is this a joint wastewater and water supply project?
If Yes=> A construction permit application for the water supply project should be submitted separately
to the Water Supply Section. A water supply permit fee may be required.
7. Is the applicant to provide treatment of effluent resulting from this construction?
If No=> A Sewage Treatment Agreement (DNR Form 29) executed by the authority providing treatment
must accompany this application.
8. Is a new or amended operation permit necessary to use the facilities described in this application?
If Yes=> A new or amended permit to operate may be requested prior to the receipt of a construction permit.
9. Is any waterline located within 10 feet; or any private or public well, lake, or public recreation area located
within 400 feet of the proposed construction?
If Yes=> Identify and locate the facility(s) relative to the proposed construction.
10. Will construction inspection be conducted by a licensed engineer employed by the applicant?
e
0
►1
■
A
■
0
0
0
►1
0
►1
If No=>
NAME OF ENGINEERING FIRM CONDUCTING INSPECTION
AECOM
11. Will this project utilize CWSRF loan funds? ❑
0
CERTIFICATION
APPLICANT
I certi at I am the authorized representative of the owner and state that
the ro ct identified above is app ed b e owner.
r ' „I 1,9...6application,
ENGINEER
I certify that all aspects of design included in this application conform to
applicable standards contained in Chapter 567 IAC 64, or that an
explanation and justification for any proposed variations from such
standards is attached. I am familiar with the information contained in this
and to the best of my knowledge, such information is complete
and accurate.
y NATURE DATE
r,(1 Ups 1 l / J�
I
SIGNATURE DATE
r JJ P
* Estimated Construction Start Date,'iComplete applications mus be submi - . a ea ' 0 days in advance of the date for
starting construction in accordance with Rules 567 IAC 60.4 and 64.2
PLEASE COMPLETE THE SCHEDULE CHECKLIST ON THE FOLLOWING PAGE OF THIS FORM
L:\work\project\60283855\400 Technical \420_Specs160283855-No Name Creek Spec\WC-No Name Creek -SCHEDULE A.docc
542-3129
Construction Permit Application
SCHEDULE A, General Information, page 2
DOCUMENT CHECKLIST
Identify all categories included in this project. Also, identify schedules attached to this application.
SCHEDULE TITLE
B Collection system
C
D
E
F
G
H1
H2
H3
Lateral Sewer Extension
Trunk & Interceptor Sewer
Wastewater Pump Station
Treatment Project Site Selection
Treatment Project Design Data
Schematic Flow Diagram
ATTACHED
0
0
0
INCLUDED IN SUBMITTAL
PROJECT DATE
04/08/13
►1
0
0
0
0
Treatment Process Loading and ❑ ❑
Removal Efficiency
Mechanical Plant Reliability ❑ ❑
I Screening, Grit Removal and Flow 0 ❑
Measurement
J Septic Tank System 0 0
K1 Controlled Discharge Pond 0 0
K2 Aerated Pond 0 0
K3 Anaerobic Lagoon 0 0
L Setting Tanks 0 0
M Fixed Film Reactor— Stationary Media 0 0
N Rotating Biological Contactor 0 0
O Aeration Tanks or Basins 0 0
P Gas Chlorination 0 0
Q Sludge Digestion and Holding 0 0
R1 Sludge Dewatering and Disposal 0 ❑
R2(A & B) Low Rate Land Application of Sludge 0 0
R3 Land Application of Sewage Sludge 0 ❑
(To be developed)
S Land Application of Wastewater 0 0
(To be developed)
Sewage Treatment Agreement 0 0
04/08/13
Identify any categories included in this project which are not provided in the above list of schedules.
DNR form 28A (Sept 2010)
LAworklproject 1802838551400 Technical1420_Specs\80283855-No Name Creek SpecWC-No Name Creek -SCHEDULE A.docc
542-3129
Iowa Department of Natural Resources
Wastewater Section
Construction Permit Application
SCHEDULE B, Collection system
DATE PREPARED
04/08/13
DATE REVISED
PROJECT IDENTITY
No Name Creek Interceptor Sewer, City of Waterloo, Iowa
City Contract No. 849
DNR USE
PROJECT NO.
PERMIT NO.
1. Identify proposed construction which is subject to flooding and explain what is proposed to prevent water from entering the
system. If no portion is subject to flooding, state none.
Segment
Flooding Protection
Raised Manholes Above "Most" Flood Events
and Provided Gasketed Manhole Lids for
Extreme Floods
*2. Indicate hydraulic capacity of: 1) the nearest downstream main or interceptor, 2) the nearest downstream lift station, and 3) all
downstream segments where flow restriction may occur. Indicate the source and accuracy of numerical data.
*3.
Location
Design capacity, MGD
Peak Hourly Dry weather Flow
MGD (actual)
Peak Hourly Wet Weather Flow
MGD (actual)
Segment Segment
Segment
MH #858 @
Downstream
End of Project*
TITUS (Midland
St.) Pumping
Station
24.5
31,500
Firm - 0.54
Total - 0.72
48,000
0.25**
0.25**
0.70**
0.70**
*Will be upgraded with
new TITUS Pumping
Station in Future
**Estimated From Previous Modeling
Identify treatment facility, the design loadings and present raw waste loadings. Indicate source and accuracy of numerical data.
Facility name and number Waterloo Water Pollution Control Facility - IDNR Permit #0790001
Facility Loading
Design
Average Wet Weather (actual)
Peak Hourly Wet Weather (actual)
MGD
#BOD5/day
34.8
88,000
24.5
31,500
60±
48,000
Provide projected design loading increase, which will be added to this facility as a result of this project. None. This project
replaces an existing 12 -inch interceptor and adds no area or flow.
Design Loading
Residential service area
Population
Flow (100 GPCD)
BOD5 (0.17 #/d/cap)
Industrial service area
Rated flow
BOD5
Other
Rated Flow
BOD5
Total BOD5
Total Flow
Peak Hourly Flow
Initial
Acres
Persons
GPD
#/day
Acres
GPD
#/day
Acres
GPD
#/day
#/day
GPD
GPD
Design Year (
* Include a written explanation of items 2 and 3 if the sewer system and/or treatment facility are overloaded.
Acres
Persons
GPD
#/day
Acres
GPD
#/day
Acres
GPD
#/day
#/day
GPD
GPD
DNR form 28B (Nov 00)
L:\work\project\602838551400 Technica11420_Specsl60283855-No Name Creek SpecWC-No Name Creek -SCHEDULE B.dooc
542-3095
DATE PREPARED
04/08/13
DATE REVISED
Iowa Department of Natural Resources
Wastewater Section
Construction Permit application
SCHEDULE D, Trunk & Interceptor Sewer
PROJECT IDENTITY
No Name Creek Interceptor Sewer, City of Waterloo, Iowa
City Contract No. 849
DNR USE
PROJECT NO.
PERMIT NO.
1. Design of reach above
A. Manhole No.
Initial area — acres
Ultimate area — acres
Initial — BOD5, #/day
Ultimate — BOD5, #/day
Initial PHWW flow— MGD
Design PHWW flow - MGD
Ultimate PHWW flow - MGD
B. Critical section of reach
Pipe diameter - inches
Slope -%
Carrying capacity - MGD
2. Pipe
Diameter— inches
Material
Joint
Maximum manhole space — feet
Total length - feet
1
11
18
18
0.20
0.25
3. Construction specifications (indicate ASTM No. or other standard included in the specifications).
A. Bedding class Type A-1 or Type CSE Embedment
B. Pipe laying SUDAS Spec 3010 Class F-3 w/ Type 1 Bedding Material
C. Compaction SUDAS Spec 4010 for PVC Pipe
D. Manhole Precast Concrete Pipe Manhole
E. Specified maximum infiltration/exfiitration rate 200 GPDPMPI
F. Infiltration/exfiltration test procedures Low Pressure Air
G. Alignment & grade test procedures
(1) During construction: Stake & batter board
(2) After construction: Lamping X
H. Deflection test procedures Go/No Go Mandrel (95% Inside Diameter)
Other
Laser X
4. Are detailed manhole drawings included? Yes ® No 0 Typical frame and cover assembly : Neenah R6461 GH Ring and Cover
Are manhole covers nonvented? Yes 0 No 0 Manhole diameter 48 in.
Manhole opening diameter 24 in. Material Precast Concrete
5. Minimum sewer & water main separation: Horizontal 10 ft. Vertical 18 in. Are specifications included? Yes ® No 0
6. Stream, road, or railroad crossing protection No
Are specifications included?
DNR form 28D (Nov 00)
L:\worklprojecfl602838551400 Technical1420_Specs160283855-No Name Creek SpecWC-No Name Creek -SCHEDULE D.docx
542-3097
18 Inch
18 Inch
PVC
PVC
Integral Bell
& Spigot
w/Gaskets
(Restrained
Joints @
Trench less
Locations)
Integral
Bell &
Spigot
w/Gaskets
383
390
3,020
1,755
3. Construction specifications (indicate ASTM No. or other standard included in the specifications).
A. Bedding class Type A-1 or Type CSE Embedment
B. Pipe laying SUDAS Spec 3010 Class F-3 w/ Type 1 Bedding Material
C. Compaction SUDAS Spec 4010 for PVC Pipe
D. Manhole Precast Concrete Pipe Manhole
E. Specified maximum infiltration/exfiitration rate 200 GPDPMPI
F. Infiltration/exfiltration test procedures Low Pressure Air
G. Alignment & grade test procedures
(1) During construction: Stake & batter board
(2) After construction: Lamping X
H. Deflection test procedures Go/No Go Mandrel (95% Inside Diameter)
Other
Laser X
4. Are detailed manhole drawings included? Yes ® No 0 Typical frame and cover assembly : Neenah R6461 GH Ring and Cover
Are manhole covers nonvented? Yes 0 No 0 Manhole diameter 48 in.
Manhole opening diameter 24 in. Material Precast Concrete
5. Minimum sewer & water main separation: Horizontal 10 ft. Vertical 18 in. Are specifications included? Yes ® No 0
6. Stream, road, or railroad crossing protection No
Are specifications included?
DNR form 28D (Nov 00)
L:\worklprojecfl602838551400 Technical1420_Specs160283855-No Name Creek SpecWC-No Name Creek -SCHEDULE D.docx
542-3097