HomeMy WebLinkAboutIowa Department of Natural Resources-1/10/2011Iowa Department of Natural Resources
Wastewater Section
Construction Permit Application
SEWAGE TREATMENT AGREEMENT
INSTRUCTIONS
This agreement must be executed for all projects where construction and sewage treatment will be provided by different parties; i.e., a
private subdivision connecting to a municipal system. This agreement must be executed by the parties who are owners at the time the
permit is issued, regardless of whether title to the proposed construction project will be transferred after completion of the project.
This agreement is not necessary when a contract for sewage treatment already exists; i.e., service contracts between municipalities.
However, the Department of Natural Resources must be informed in writing that the contractual agreement does exist.
APPLICANT
ENGINEER
OWNER
Lost Island Real Estate, LC
FIRM
Wayne Claassen Engineering and Surveying, Inc.
ADDRESS
2225 E. Shaulis Rd, Waterloo, IA 50701
ADDRESS
P.O. Box 898, Waterloo, IA 50704
REPRESENTATIVE
Gary Bertch.
TELEPHONE
319-233-8414
PROJECT OFFICER
William J. Claassen, P.E.
TELEPHONE
319-235-6294
PROJECT IDENTIFICATION
Bamboo Ridge Area Sanitary Sewer Relocation and Improvements, Waterloo, Iowa
OWNER AND SYSTEM RECEIVING WASTES
City of Waterloo
CERTIFICATE
I am the authorized representative of the owner identified above and state that the proposed sanitary sewerage facilities shall be
constructed in accordance with the plans and specifications and all wastes contributed by this project shall be discharged to the
treatment system identified above.
/ TURE 777
TITLE
Owner
DATE
/- 7/C
AGREEMENT TO PROVIDE SEWAGE TREATMENT
I am the authorized representative of the owner of the system identified above and state that the connection of the proposed sanitary
sewerage facilities identified above is approved by the owner, and that the owner accepts responsibility for providing adequate
treatment of all wastes contributed by this project, in accordance with the provisions of Chapter 455B, Code of Iowa, and the rules
of the Department of Natural Resources. This agreement shall not be construed in any way to affect any local ordinances, sewer
service agreements, or fee systems entered into between the parties.
SIGN R�E� (4? il
.�2��lu'/+� � �
TYPED OR PRINTED NAME
Buck Clark
TITLE
Mayor
PHONE NUMBER
319-291-4301
DATE
I] L D gti I
DNR form 29 (Nov 00)
542-3219
Iowa Department of Natural Resources Wastewater Section
Construction Permit Application
SCHEDULE A, General Information
APPLICANT
ENGINEER
OWNER E-MAIL ADDRESS
Lost Island Real Estate, LC Gary.Bertch@bertch.com
FIRM E-MAIL ADDRESS
Wayne Claassen Engineering and Surveying, Inc claassen@wcesinc.com
ADDRESS
2225 E. Shaulis Rd, Waterloo, IA 50701
ADDRESS
2705 University Ave., Waterloo, IA 50704-0898
REPRESENTATIVE TELEPHONE
Gary Bertch 319-233-8414
PROJECT OFFICER TELEPHONE
William J. Claassen 319-235-6294
PROJECT IDENTIFICATION
Bamboo Ridge Area Sanitary Sewer Relocation and Improvements
ESTIMATED START DATE *
02/01/2011
ESTIMATED COMPLETION DATE
04/01/2011
PLEASE RESPOND TO ALL QUESTIONS YES NO
1. Has an engineering report, facilities plan or other information previously been submitted for this project? ❑ X
If Yes=>
PROJECT IDENTITY
DATE SUBMITTED
2. Does the project and construction permit application, as submitted, follow the recommendations, design
loadings, construction schedule, permit limits, and conclusions of the approved engineering report or
facilities plan?
If No=> Provide the design basis and technical information justifying all changes.
3. Are there three complete sets of plans and specifications accompanying this application?
For a minor gravity sewer extension within the meaning of 455B.183.3 Code of Iowa and Design
Standard 11.1, two complete sets will be adequate for expeditious approval. For more complex projects,
three sets of plans and specifications may be requested.
4. Are approved standard specifications a part of this application?
N
A
❑
❑
X ❑
X ❑
If Yes=>
APPROVED STANDARD SPECIFICATIONS OF
(municipality or firth)
City of Waterloo
DATE APPROVED
5. Does each set of plans and specifications or engineering report accompanying this application contain a
"professional engineering seal" executed in conformance with 542B.16, Code of Iowa? X ❑
If No=> Processing will be delayed pending receipt of applicable design schedules and certified plans,
specifications or engineering report.
6. Is this a joint wastewater and water supply project? ❑ X
If Yes=> A construction permit application for the water supply project should be submitted separately to the
Water Supply Section. A water supply permit fee may be required.
7. Is the applicant to provide treatment of effluent resulting from this construction? ❑ X
If No=> A Sewage Treatment Agreement (DNR Form 29) executed by the authority providing treatment must
accompany this application.
8. Is a new or amended operation permit necessary to use the facilities described in this application? ❑ X
If Yes=> A new or amended permit to operate may be requested prior to the receipt of a construction permit.
9. Is any waterline located within 10 feet; or any private or public well, lake, or public recreation area located
within 400 feet of the proposed construction? ❑ X
If Yes=> Identify and locate the facility(s) relative to the proposed construction.
10. Will construction inspection be conducted by a licensed engineer employed by the applicant? ❑ X
If No=>
NAME OF ENGINEERING FIRM CONDUCTING INSPECTION
Wayne Claassen Engineering and Surveying, Inc
11. Will this project utilize CWSRF loan funds? ❑ X
CERTIFICATION
APPLICANT
I certify that I am the authorized representative of the owner and
state that the project identified above is approved by the owner.
ENGINEER
I certify that all aspects of design included in this application
conform to applicable standards contained in Chapter 567 IAC
64, or that an explanation and justification for any proposed
variations from such standards is attached. I am familiar with the
information contained in this application, and to the best of my
knowledge, such information is complete and accurate.
SIGNAT DATE
a
-- /z z//� 9
�=-ti.-• /2 /ZZ//C�
SIGNATURE
VAL'j44
DATE
* Estimated Construction Start Date: Complete applications must be submitted a ast 120 days in advance f the date for
starting construction in accordance with Rules 567 IAC 60.4 and 64.2
PLEASE COMPLETE THE SCHEDULE CHECKLIST ON THE FOLLOWING PAGE OF THIS FORM
DNR form 28A (Sept 2010)
542-3129
Iowa Department ofNatural Resources
Wastewater Section
Construction Permit Application
SCHEDULE A, General Information
SCHEDULE
Identify all categories
TITLE
B Collection system
C
D
E
F
G
H1
H2
H3
I
J
K1
K2
K3
L
M
N
0
P
DOCUMENT CHECKLIST
included in this project. Also, identify schedules attached to this application.
INCLUDED IN
ATTACHED PROJECT
X ❑
Lateral Sewer Extension
Trunk & Interceptor Sewer
Wastewater Pump Station
Treatment Project Site Selection
Treatment Project Design Data
Schematic Flow Diagram
Treatment Process Loading and
Removal Efficiency
Mechanical Plant Reliability
Screening, Grit Removal and Flow
Measurement
Septic Tank System
Controlled Discharge Pond
Aerated Pond
Anaerobic Lagoon
Setting Tanks
Fixed Film Reactor — Stationary Media
Rotating Biological Contactor
Aeration Tanks or Basins
Gas Chlorination
Q Sludge Digestion and Holding
R1 Sludge Dewatering and Disposal
R2(A & B) Low Rate Land Application of Sludge
R3 Land Application of Sewage Sludge
(To be developed)
S Land Application of Wastewater
(To be developed)
Sewage Treatment Agreement
X
SUBMITTAL
DATE
Identify any categories included in this project which are not provided in the above list of schedules.
DNR form 28A (Sept 2010)
542-3129
Iowa Department of Natural Resources
Wastewater Section
Construction Permit Application
SCHEDULE B, Collection system
DAZE PREPARED PROJECT IDENTITY
12/21/2010 Bamboo Ridge Area Sanitary Sewer Relocation and Improvements, Waterloo,
IA
DATE REVISED
PROJECT NO.
PERMIT NO.
1. Identify proposed construction which is subject to flooding and explain what is proposed to prevent water from entering the
system. If no portion is subject to flooding, state none.
Segment
San -S1 & S8
Flooding Protection
Water -tight manholes
*2. Indicate hydraulic capacity of: 1) the nearest downstream main or interceptor, 2) the nearest downstream lift station, and
3) all downstream segments where flow restriction may occur. Indicate the source and accuracy of numerical data.
Location
Design capacity, MGD
Peak Hourly Dry weather Flow
MGD (actual)
Peak Hourly Wet Weather Flow
MGD (actual)
Segment
Segment
Segment
30" Sink Creek
Interceptor
15" at tie-in
San -S1
24.53
18.72
2.83
48,000 peak day
1.1
0.1
1.31
0.2
9. Identify treatment facility, the design loadings and present raw waste loadings. Indicate source and accuracy of numerical data.
Facility name and number
Facility Loading
Design
Average Wet Weather (actual)
Peak Hourly Wet Weather (actual)
MGD
#BODS/day
34.8
88,000
24.53
31,500 avg day
60+
48,000 peak day
Provide projected design loading increase, which will be added to this facility as a result of this project.
Design Loading
Initial
Design Year (20 30
Residential service area Acres Acres
Population 378 Persons 2,079 Persons
Flow (100 GP CD) 37,800 GPD 207,900 GPD
BOD5 (0.17 #/d/cap) 64 #/day 353 #/day
Industrial service area 0 Acres 0 Acres
Rated flow 0 GPD 0 GPD
BOD5 0 #/day 0 #/day
Other RV park and 0 Acres 60 Acres
Commercial
Rated Flow
BOD5
Total BOD5
Total Flow
Peak Hourly Flow
0 GPD 23,300 GPD
#/day 39.6 #/day
64 #/day 393 #/day
37,800 GPD 231,200 GPD
151,200 GPD 924,800 GPD
Include a written explanation of items 2 and 3 if the sewer system and/or treatment facility are overloaded.
DNR form 28B (Nov 00)
542-3095
Iowa Department of Natural Resources
Wastewater Section
Construction Permit application
SCHEDULE D, Trunk & Interceptor Sewer
DATE PREPARED
12/21/10
DATE REVISED
PROJECT IDENTITY
Bamboo Ridge Area Sanitary Sewer Relocation and Improvements, Waterloo,IA
DNR USE
PROJECT NO.
PERMIT NO.
1. Design of reach above
A. Manhole No.
Initial area — acres
Ultimate area — acres
Initial — BOD5, #/day
Ultimate — BOD5, #/day
Initial PHWW flow — MGD
Design PHWW flow - MGD
Ultimate PHWW flow - MGD
B. Critical section of reach
Pipe diameter - inches
Slope - %
Carrying capacity - MGD
2. Pipe
Diameter — inches
Material
Joint
Maximum manhole space — feet
Total length - feet
S17
S7
S1
20
60
60
160
300
400
34
64
64
188.7
348.5
393
.0.08
0.15
0.15
0.44
0.82
0.92
0.44
0.82
0.92
S17/S8
S17/S8
SI/S7
12-Exis
12-Exis
15
0.74
0.74
0.4
1.98
1.98
2.64
3. Construction specifications (indicate ASTM No. or other standard included in the specifications).
A. Bedding class CLASS 1A
B. Pipe laying ASTM D3034,D2321
C. Compaction 95% PROCTOR
D. Manhole ASTM C476, C443
E. Specified maximum infiltration/exfiltration rate 200
F. Infiltration/exfiltration test procedures air
G. Alignment & grade test procedures TV
(1) During construction: Stake & batter board Laser X
(2) After construction: Lamping X Other TV
H. Deflection test procedures Mandrel
4. Are detailed manhole drawings included? Yes // No ❑ Typical frame and cover assembly :
Are manhole covers nonvented? Yes ® No ❑ Manhole diameter 48-72 in.
Manhole opening diameter 24 in. Material PRECAST PCC & CAST IRON
R1643
5. Minimum sewer & water main separation: Horizontal 10
ft. Vertical 18
in. Are specifications included?
6. Stream, road, or railroad crossing protection NA
Are specifications included? NA
DNR form 28D (Nov 00)
542-3097
8
15
Truss
Truss
Rubber
Rubber
396
415
2645
2354
3. Construction specifications (indicate ASTM No. or other standard included in the specifications).
A. Bedding class CLASS 1A
B. Pipe laying ASTM D3034,D2321
C. Compaction 95% PROCTOR
D. Manhole ASTM C476, C443
E. Specified maximum infiltration/exfiltration rate 200
F. Infiltration/exfiltration test procedures air
G. Alignment & grade test procedures TV
(1) During construction: Stake & batter board Laser X
(2) After construction: Lamping X Other TV
H. Deflection test procedures Mandrel
4. Are detailed manhole drawings included? Yes // No ❑ Typical frame and cover assembly :
Are manhole covers nonvented? Yes ® No ❑ Manhole diameter 48-72 in.
Manhole opening diameter 24 in. Material PRECAST PCC & CAST IRON
R1643
5. Minimum sewer & water main separation: Horizontal 10
ft. Vertical 18
in. Are specifications included?
6. Stream, road, or railroad crossing protection NA
Are specifications included? NA
DNR form 28D (Nov 00)
542-3097