That Section 5,National Electrical Code Adoption, of Chapter 3, Electrical Regulations,
of Title 9, Building Regulations, of the 2007 Code of Ordinances of the City of Waterloo, Iowa,
is hereby amended to strike the current provisions thereof and to substitute the following new
provision in its place: 9-3-5:
A. The 2017 Edition of the National Electrical Code, including Article 90, Chapters 1
through 9, and Annex A, B, C, D and H, inclusive, as published by the National Electrical Code
Committee, and adopted by the National Fire Protection Association, is hereby adopted by
reference and is effective as if fully set forth in this article. Where, in any specific case, different
sections of this article specify different materials, methods of construction or requirements,the
most restrictive shall govern.
That Section 6,National Electric Code Amendments, of Chapter 3, Electrical Regulations
of Title 9, Building Regulations, of the 2007 Code of Ordinances of the City of Waterloo, Iowa,
is hereby amended to strike the current provisions thereof and to substitute the following new
provision in its place: 9-3-6:
A. Amendments to 2017 NEC Chapter 2 Amendments:
1. 210.8(A)(2) Add the following exceptions to section 210.8, paragraph (A),
subparagraph(2):
a. Exception No.I to (2): Receptacles not readily accessible.
b. Exception No.2 to (2): A single receptacle or a duplex receptacle for
two appliances located within dedicated space for each appliance that,
in normal use, is not easily moved from one place to another and that
is cord-and-plug connected in accordance with 400.7(A)(6), (A)(7),
or(A)(8).
c. Receptacles installed under the exceptions to 210.8(A)(2) shall not be
considered as meeting the requirements of 210.52(G). Where readily
accessible,receptacle shall be labeled as being non-GFCI".
2. 210.8(A)(5) Add the following exceptions to section 210.8, paragraph (A),
subparagraph(5):
a. Exception No.2 to (5): Receptacles that are not readily accessible.
b. Exception No. 3 to (5): A single receptacle or a duplex receptacle for
two appliances located within dedicated space for each appliance that,
in normal use, is not easily moved from one place to another and that
is cord-and-plug connected in accordance with 400.7(A)(6),(A)(7), or
(A)(8).
c. Receptacles installed under the exceptions to 210.8(A)(5) shall not be
considered as meeting the requirements of 210.52(G). Where readily
accessible, receptacle shall be labeled as being non-GFCI".
Ordinance No. 5428
Page 2
3. 210.12 (D) is amended by deleting section 210.12
(D). Delete section 210.12(D).
4. 220.12 is amended by deleting the exception to section 220.12 and insert in
lieu thereof the following exception: EXCEPTION: Where the building
is designed and constructed to comply with an energy code adopted by the
local authority, the lighting load shall be permitted to be calculated at the
values specified in the energy code.
5. 230-30 Insulation, is amended by deleting the italicized paragraph entitled
"Exception" (1) through (4) in its entirety, and adding the following new
unnumbered exception:
Exception: A grounded conductor shall be permitted to be uninsulated if it
is part of a service entrance cable assembly.
6. "230-43. Wiring Methods for 1000 Volts, Nominal, or Less, is amended by
deleting items (1) and (6), and by adding the following as a new
unnumbered paragraph at the end of the enumerated paragraphs: "Only
items (3) Rigid, metal conduit and (4) Intermediate metal conduit may be
concealed."
7. 230-50(A) Underground Service Entrance Conductors is deleted in its entirety
and the following sentence is substituted therefore: "Service lateral
conductors shall be installed in a raceway not less than two feet
underground."
8. 250.52(a)(5) Rod and Pipe Electrodes, is deleted in its entirety and the
following is substituted therefore: "Rod electrodes shall be not less than
2.5m (8 ft.) in length, not less than 15.87mm(5/8 inch)in diameter, and
shall be copper clad or equivalent."
9. 250.118 Delete Items#5,#6 and#7 and insert the
following: (5) All listed flexible metal conduit shall contain a wire type
equipment grounding conductor. (6)All listed liquid tight flexible metal
conduit shall contain a wire type equipment grounding conductor. (7) All
flexible metallic tubing shall contain a wire type equipment grounding
conductor.
B. 2014 NEC Chapter 3 Amendments
1. 300.13(B) Device Removal is deleted in its entirety and the following is
substituted therefore:
"(B) Device Removal. In all circuits the continuity of conductors shall not
be dependent upon device connections where the removal of such devices
would interrupt continuity."
2. 10.15(b)(7) 120/240-Volt, 3-Wire, Single-Phase Dwelling Services and
Feeders), is deleted in its entirety.
C. Chapter 4 Amendment
1. 406.4(D)(4) is amended by deleting section 406.4(D)(4). Delete section
406.4(D)(4).