July 31, 2019
Mr. Randy Bennett
Waste Management Services
3505 Easton Avenue
Waterloo, Iowa 50702
AECOM
501 Sycamore Street
Suite 222
Waterloo, Iowa 50703
www.aecom.com
Subject: Change Order No. 2
Flow Equalization Facility Overflow Connection to Satellite WPCF
Waterloo, Iowa
City Contract No. 880
AECOM #60507078
Dear Mr. Bennett:
319-232-6531 tel
319-232-0271 fax
Enclosed please find Change Order No. 2 for the above -referenced project. The purpose of this change order is
to power and control sump pumps in the metering manhole and the control valve manhole from the Blower Building
at the Satellite Plant and via SCADA system. The contract documents called for a control cabinet that would no
longer be required as controls would be routed to the Blower Building.
It is recommended to move forward with this Change Order No. 2 in the amount of $10,078.83. If you have any
questions or need additional information, please let us know. Thank you.
Yours sincerely,
Ross A. Hillsman, PE
Enclosure: As Noted
c: Boomerang Corporation
P:\605070781600_Construction_Support\670_Change-Orders12019-7-31 Tmsmtl to Randy Bennett Watedoo FEQ Overflow - CO #2.docx
CHANGE ORDER NO. 2
Owner: City of Waterloo, Iowa Date: July 31, 2019
Project: Flow Equalization Facility Overflow Connection to Satellite WPCF
Owner's Contract No.: City Contract No. 880 Contractor: Boomerang Corporation
Date of Contract Start: November 27, 2017 $ Original Contract: $693,700
You are directed to make the following changes in the Contract Documents. Description:
Add new conduit and wiring to run and control the sump pumps from the blower building in lieu of controlling them via local control
cabinet. Deduct the costs for the control cabinet as originally indicated in the contract documents.
Addition for Conduit and Wiring $11,328.83
Deduct for Control Cabinet $( 1,250.00)
NET ADD $10,078.83
Reason for Change Order:
The purpose of the change is to power and control the sump pumps in the metering manhole and the control valve manhole from the
Blower Building at the Satellite Plant and via SCADA system. The contract documents called for a control cabinet that would no
longer be required as controls would be routed to the Blower Building. A deduct is included for the cabinet.
CONTRACT PRICE
Original: $ 693,700.00
Previous C.O.s (ADD/DEDUCT): $ 39,237.42
This C.O. (ADD/DEDUCT): $ 10,078.83
Contract Price With All Approved
Change Orders:
Original:
Previous C.O.s (ADD/DEDUCT):
This C.O. (ADD/DEDUCT):
$ 743,016.25 REVISED:
Original Completion Date:
Revised Completion Date:
CONTRACT TIMES (Calendar Days)
To Substantial To Final
Completion Completion
May 31, 2018
To Be
Determined
It is agreed by the Contractor that this Change Order includes any and all costs associated with or resulting from the change(s) ordered herein, including
all impact, delays, and acceleration costs. Other than the dollar amount and time allowance listed above, there shall be no further time or dollar
compensation as a result of this Change Order.
THIS DOCUMENT SHALL BECOME AN AMENDMENT TO THE CONTRACT AND ALL
STIPULATIONS AND COVENANTS OF THE CONTRACT SHALL APPLY HERETO
APPROVED lj
City of Waterloo (Authorized Signature)
By:
ACCEPTED:
By:
oomerang Corporation (Authorized Signature)
P:`605070781600_Construction_Support\670_Change-Orders12019-07-31 -CO2-FSQ (002).docPage 1 of 1
/f 1
Date:
Date:
AECOM
60507078 2
Project No. Change Order No.