HomeMy WebLinkAbout1023 W 2nd St-Rental Property Inspection-4/2/2019Rental Property Inspection Report
City of Waterloo
715 Mulberry Street,
Waterloo, Iowa 50703
PH (319)-291-4319 Fax (319)-291-4262
Inspection Number 786
Inspector* Barry Stratton
Re -inspection Date 5/23/2019
Re -inspection # 2
File Upload
Property Info
Inspection Date* 4/2/2019
Unit Of
Street Address:* 1023 W 2nd St
Tenant Name:
Phone Number:
Property Owner Info
Property Owner Name: Keith Risse
Property Owner
Email
Property Owner
Address:
Property Owner Phone:
Inspection Items
3029 Huntington Rd Waterloo, IA 50701
Item Status
Address Posted r Pass r Cond r Fail
Siding r Pass r Cond r Fail
Roof r Pass r Cond r Fail
Item Status
Porches f Pass f Cond l: Fail
Chimney r Pass r Cond r Fail
Basement r Pass r Cond F Fail
Steps(outside) (Pass (Cond F Fail
Foundation (Pass (Cond r Fail
Hot Water Heater (Pass (Cond r Fail
Heating System r Pass r Cond r Fail
Electric (Pass (Cond F Fail
Plumbing r Pass r Cond F Fail
Egress (Pass (Cond F Fail
Garbage r Pass r Cond F Fail
Dining Room r Pass r Cond r Fail
Livingroom r Pass r Cond F Fail
Bedroom r Pass r Cond F Fail
Kitchen r Pass (Cond F Fail
Bathe room r Pass r Cond r Fail
Appliances r Pass r Cond F Fail
Floors r Pass r Cond r Fail
Windows -Locks r Pass r Cond F Fail
Door -Locks r Pass r Cond F Fail
Smoke Detectors r Pass r Cond F Fail
Stairs(Inside) r Pass r Cond F Fail
Handrails r Pass r Cond F Fail
Misc. Hazards -list r Pass r Cond F Fail
Fire Extinguishers r Pass r Cond F Fail
Common Area r Pass r Cond F Fail
Attach Photos
Comments
Violation Comments
IFC 907 915 IPMC 704
Smoke detectors are needed in each bedroom and
outside of the bedrooms. CO detector is needed in
vicinity of the bedrooms. Smoke detector is also
needed in basement and needs to be in working
condition.
Violation Comments
IPMC 304.10
Stairs and porches need to be maintained
structurally sound, in good repair, and be capable of
supporting the imposed loads. Concrete stairs are
broken and need replaced. Also need approved
handrails on porch to house.
IPMC 605 Electrical needs repaired. All switches and outlets
need approved covers. Ceiling fan in living room not
wired correctly. Electric panel in basement missing
breaker and panel is not grounded. 10/3 wire to 220
V dryer needs secured to code and 220 V box needs
secured to wall.
All light fixtures need approved covers/globes on
inside and outside of house. All lights fixtures need
bulbs installed that are missing.
Open electric wires in wall in living room need
terminated.
Open electric on front entry.
IPMC 304.13 304.14
All windows need to be in good repair and weather
tight. Windows need to be easily openable and
capable of preforming their intended function. All
windows need approved locks and hardware
installed. Screens need to be in place on all
habitable rooms windows.
IPMC 305 Peeling and abraded paint in unit needs corrected.
All surfaces shall be maintained in good condition.
IPMC 504 Water heater does not have a cold water shut off
valve. PEX lines installed to washer not secured to
code. All fixtures shall be maintained in a safe and
functional condition.
Bathroom sink does not drain properly.
Toilet is not set on floor mounting base toilet moves
on floor.
Standing water in basement need corrected.
IPMC 304.15
All doors, assemblies, and hardware shall be
maintained in good condition. Door need to be
weather tight, have proper molding installed around
doors, and doors shall tightly secure door to jam.
Back door is not weather tight and front door jam is
busted in several areas.
IPMC 304.12 Handrails are needed to upstairs, basement & on
front steps.
IPMC 304.5 Stairs to basement the treads need replaced.
Treads are not an approved tread material. Upstairs
treads are loose in areas and need treads replaced.
IPMC 108.1.2 Stove is unsafe to the occupants because of faulty
igniters and stove does not function as intended.
Replace stove.
IPMC 102.5 IRC 105 All electric & plumbing work requiring licensed
contractors to do the work.
9-7-4 9-7-5 Rental registration needs to be updated with current
information.
Fees
Initial Fees $
Initial Unit $
Additional Units $
Common Area $
Total Fee* $ 0.00
Does the property r No ( Yes
require another
inspection?
Time 10:30