HomeMy WebLinkAbout402 Allen St # 1-Rental Property Inspection-8/8/2019 Rental Property Inspection Report City of Waterloo 715 Mulberry Street, Waterloo, Iowa 50703 PH(319)-291-4319 Fax(319)-291-4262 Inspection Number 853 Inspector* Barry Stratton Re-inspection Date 9/9/2019 Re-inspection# 2 File Upload Property Info Inspection Date* 8/8/2019 Unit Of Street Address:* 402 Allen St#1 Tenant Name: Phone Number: Property Owner Info Property Owner Name: Owl Investments LLC Property Owner Email Property Owner 1709 260th St Janesville, IA 50647 Address: Property Owner Phone: 319-404-4031 Inspection Items Item Status Address Posted r Pass r Cond f Fail Siding r Pass r Cond (Fail Roof r Pass r Cond (Fail Porches r Pass f Cond r Fail Chimney r Pass C Cond r Fail Basement C3 Pass C Cond r Fail Steps(outside) O Pass C Cond r Fail Foundation O Pass C3 Cond r Fail Hot Water Heater C5 Pass 0 Cond r Fail Heating System C3 Pass 0 Cond r Fail Electric C3 Pass 0 Cond r Fail Plumbing O Pass n Cond r Fail Egress O Pass (Cond r Fail Garbage C5 Pass (Cond r Fail Dining Room C3 Pass (Cond f Fail Livingroom C3 Pass (Cond r Fail Bedroom O Pass O Cond r Fail Kitchen O Pass O Cond r Fail Batheroom C5 Pass O Cond r Fail Appliances r Pass (Cond r Fail Floors r Pass (Cond r Fail Windows-Locks r Pass (Cond r Fail Door-Locks C3 Pass (Cond r Fail Smoke Detectors O Pass (Cond r Fail Stairs(Inside) C5 Pass O Cond (Fail Handrails r Pass r Cond r Fail Misc. Hazards-list C Pass C Cond r Fail Fire Extinguishers O Pass r Cond r Fail Common Area O Pass O Cond r Fail Attach Photos Comments Violation Comments IFC 907 915 IPMC 704 Smoke detectors needed in each bedroom and outside bedrooms.CO detectors needed in vicinity of the bedrooms.Smoke detector is needed in attic. IRC 311.7.8 Handrails need to comply with code on all stairs. IPMC 305 Peeling&abraded paint shall be corrected. Paint on windowframe have the potential to have lead and lead base needs to be corrected if present. All holes in walls need repaired. Floors&surfaces shall be maintained in good condition.condition. Need transition strips in place where trip hazards can occur. Ceiling in kitchen needs repaired. Kitchen counter needs replaced. Counter not secured to cabinet. IPMC 304.13 Need to repair all broken windows and missing windows. Every window except a fixed window shall be easily operable and capable of being held in the position by window hardware. IPMC 605 Need switch covers and outlet covers on several fixtures in unit. Outlets in kitchen are wired with Hot/neutral reversed. Outlet in bathroom is not grounded. Licensed electrician will need to make corrections. Exposed romex in hallway from kitchen to bathroom. Multiple outlet in use in bedroom.These are not allowed and need removed. Ceiling fan has exposed wires. All lights will need approved globes. IPMC 702 Egress path is blocked by a refrigerator in hallway. IPMC 304.15 Rear door is not maintained weather tight. Entrance door and hardware need to maintained in good condition and capable of securing door. Main entrance door is missing trim. IPMC 304.10 Stairs at rear door need replaced. Deck and stairs are unsafe. IFC 1025 Egress path need lighting at door @ rear door. IPMC 108.1.2 Electric in unit is unsafe and needs corrected by licensed electrician. Fees Initial Fees $ Initial Unit $ Additional Units $ Common Area $ Total Fee* $ 0.00 Does the property r No r Yes require another inspection? Time 9:00 i i