HomeMy WebLinkAbout1315 Lafayette St-Rental Property Inspection-2/26/2019 Rental Property Inspection Report City of Waterloo 715 Mulberry Street, Waterloo, Iowa 50703 PH(319)-291-4319 Fax(319)-291-4262 Inspection Number 772 Inspector* Barry Stratton Re-inspection Date 3/26/2019 Re-inspection# 2 File Upload Property Info Inspection Date* 2/26/2019 Unit Of Street Address:* 1315 Lafayette St Tenant Name: Phone Number: Property Owner Info Property Owner Name: CNC Investments LLC Property Owner Email Property Owner 5317 University Ave Cedar Falls, IA 50613 Address: Property Owner Phone: Inspection Items Item Status Address Posted r Pass r Cond r Fail Siding r Pass r Cond r Fail Roof r Pass r Cond r Fail Item Status Porches f Pass f Cond r Fail Chimney r Pass r Cond r Fail Basement r Pass r Cond F Fail Steps(outside) (Pass f Cond r Fail Foundation (Pass f Cond F Fail Hot Water Heater (Pass f Cond r Fail Heating System r Pass r Cond r Fail Electric (Pass f Cond F Fail Plumbing r Pass r Cond F Fail Egress (Pass f Cond F Fail Garbage r Pass r Cond F Fail Dining Room r Pass r Cond r Fail Livingroom r Pass r Cond r Fail Bedroom r Pass r Cond F Fail Kitchen (Pass f Cond F Fail Batheroom r Pass r Cond F Fail Appliances (Pass f Cond F Fail Floors (Pass f Cond F Fail Windows-Locks (Pass f Cond F Fail Door-Locks (Pass f Cond F Fail Smoke Detectors r Pass r Cond F Fail Stairs(Inside) (Pass f Cond F Fail Handrails (Pass f Cond r Fail Misc. Hazards-list r Pass r Cond F Fail Fire Extinguishers (Pass f Cond F Fail Common Area r Pass r Cond r Fail Attach Photos Comments Violation Comments IFC 907 915 IPMC 704 Smoke detectors needed in each room used for sleeping purposes. CO detectors needed in vicinity of the bedrooms. Smoke detector needed in basement. Violation Comments 9-7-49-7-5 Rental registration is only for 1 unit. 2 units at listed address. Need updated rental registration for listed address. IPMC 304.3 No premises identification listed for 2 units. IPMC 304.15 Entry doors have broken jams and doors are not weather tight. Doors are damaged and not maintained in good condition.All doors to units shall be maintained in good condition and meet fire code for fire separation. IPMC 305.6 Interior doors are broken and missing. Interior doors shall fit reasonably well within its frame and shall be capable of being opened and closed by properly securing to the jambs. IPMC 403.2 Bath exhaust is not currently working. Birds potentially nesting in flue to the outside. IPMC 504 Bathtub and surround need replaced. Fixtures shall be properly installed and maintained in working condition. Fixtures shall be maintained in a safe, sanitary and functional condition. IPMC 305 All holes in walls need repaired. Peeling and abraded paint needs corrected. Several areas in kitchen, back bedroom,and dining room ceilings have water damage where it is leaking. Repair/replace all missing trim on floor,walls,and doors. IPMC 605 Several outlets in unit are not grounded and some not working. Have a licensed electrical contractor make required corrections to meet code. Electric cover missing on furnace switch on Goodman furnace. All lights shall require globes installed on fuxtures. IPMC 603 IRC 105 Furnace installed in basement does not have proper permits and inspections. Contact licensed contractor to obtain permits and inspections. IPMC 306 Kitchen cabinets missing doors and drawer fronts. have cabinets repaired. IPMC 309 Mice and mice feces in unit. Have infestation promptly exterminated by an approved processes that will not be injurious to the occupants. IPMC 304.7 Several ice dams on house potentially causing water leaks to house. Repair all areas that have water damage. IPMC 702 Egress door in back is blocked and not accessible.A safe continuous unobstructed path shall be provided. IFC 605.5 Multiple adapters in use in unit and are not allowed and shall be removed. IPMC 304.5 Foundation walls leaking in basement. Violation Comments IPMC 603 Stove is installed and maintained in a safe working condition. Replace stove or repair stove currently in unit. All required clearances shall be maintained for combustion and exhaust air on furnaces. IRC 302.3 Unit listed in rental registration as single family.2 units currently at listed address. Fire separation needs to be meet 1 hour separation. IPMC 108.1.3 Structure in its current condition is unfit to occupy because of lack of maintenance, electric hazards, insanitary bathroom,and IPMC violations pertaining to rental regulations. IPMC 102.5 All HVAC&electric work shall be done by licensed contractors and have inspections on the work done. Fees Initial Fees $ Initial Unit $ Additional Units $ Common Area $ Total Fee* $ 0.00 Does the property r No F Yes require another inspection? Time 10:00