HomeMy WebLinkAbout709 W 5th St-Rental Property Inspection-2/14/2019 Rental Property Inspection Report
City of Waterloo
715 Mulberry Street,
Waterloo, Iowa 50703
PH(319)-291-4319 Fax(319)-291-4262
Inspection Number 768
Inspector* Barry Stratton
Re-inspection Date 3/14/2019
Re-inspection# 2
File Upload
Property Info
Inspection Date* 2/14/2019
Unit Of
Street Address:* 709 W 5th St
Tenant Name:
Phone Number:
Property Owner Info
Property Owner Name: Quality Concrete Construction INC
Property Owner
Email
Property Owner 1930 Hawthorne Ave#1 Waterloo, IA 50702
Address:
Property Owner Phone:
Inspection Items
Item Status
Address Posted r Pass r Cond r Fail
Siding r Pass r Cond r Fail
Roof r Pass r Cond r Fail
Item Status
Porches C Pass C Cond f Fail
Chimney C Pass C Cond (Fail
Basement C Pass C; Cond f•Fail
Steps(outside) C Pass C Cond f•Fail
Foundation C Pass C Cond (Fail
Hot Water Heater C Pass C Cond f•Fail
Heating System O Pass O Cond (Fail
Electric a Pass C Cond f•Fail
Plumbing a Pass C Cond (Fail
Egress C Pass C Cond (Fail
Garbage C Pass C Cond (Fail
Dining Room C Pass C Cond f•Fail
Livingroom O Pass C) Cond C Fail
Bedroom O Pass C Cond F Fail
Kitchen C Pass C Cond f•Fail
Batheroom C Pass C` Cond f•Fail
Appliances C Pass C Cond (Fail
Floors f Pass r) Cond f• Fail
Windows-Locks C Pass C Cond f•Fail
Door-Locks C Pass C Cond f•Fail
Smoke Detectors C Pass r Cond f•Fail
Stairs(Inside) C Pass r Cond (Fail
Handrails C Pass r Cond f•Fail
Misc. Hazards-list C Pass C Cond f•Fail
Fire Extinguishers C Pass C Cond f•Fail
Common Area C Pass C Cond (Fail
Attach Photos
Comments
Violation Comments
IFC 907 915 IPMC 704 Smoke detectors needed in each bedroom and
outside bedrooms. Smoke detectors needed on
each level and in basement. CO detectors needed in
vicinity of the bedrooms.
Violation Comments
IPMC 304.13 All windows need to be maintained in good condition.
Repair all broken windows. Front window do not
close and are letting in a lot of outside air.Windows
other that a fixed window shall be easily operable
and capable of being held in position by window
hardware.Windows that are screwed shut will need
to be removed and made functional. Repair all non-
functional windows and ensure they are in good
condition and weather tight.
IFC 906 Updated fire extinguisher needed.
IPMC 605 Several outlets are burned and need replaced.
Ceiling fan in living room needs replaced. Light in
kids bedroom needs approved fixture to hang light in
bedroom. Exposed wires behind bathroom door
need terminated.
IPMC 305 Floors need newflooring installed in kitchen,
upstairs hallway, and in bathroom. Ceiling in dining
room is leaking and missing tiles. Fix ceiling in dining
room. Ceiling in kids bedroom needs repaired.All
holes and peeling paint on walls will need repaired.
IPMC 403.5 Dryer is exhausting in basement and needs to
exhaust to the exterior.
IPMC 504 Water heater is missing the discharge tube.Toilet is
needed new lid/seat. Bathtub surround needs
replaced.
IPMC 304.15 All doors door assemblies, operating systems,and
hardware shall be maintained in good condition and
weather tight. Front door needs replaced. Screen
door needs replaced since it is broken.
IPMC 305.6 Interior doors shall fit reasonable well within its
frame, and shall be capable of being opened and
closed by properly and securely attached to jambs.
All doors shall have the property hardware attached
to the doors.
IPMC 602 Register covers need to be secured to the registers.
Furnace needs to maintain 68 degrees in unit.
Thermostat not functioning as intended. Check
furnace and thermostat by a licensed contractor
licensed to do work in Waterloo.
IPMC 309 Rodent infestation in unit. Mice will need to be
exterminated by an approved method that will not be
injurious to occupants. Hire exterminator to eliminate
infestation.
IPMC 304.7 Sever ice dam from gutters being full and not being
able to drain. Remove all ice dams.
IPMC 307 Handrails are needed to basement.
IPMC 304.10 Front deck flooring needs replaced.All decking shall
be maintained structurally sound and in good repair
with proper anchorage and capable of supporting
the imposed loads.
Fees
Initial Fees $
Initial Unit $
Additional Units $
Common Area $
Total Fee* $ 0.00
Does the property r No r Yes
require another
inspection?
Time 1:00