HomeMy WebLinkAbout1001 Baltimore St-Rental Property Inspection-1/18/2019Rental Property Inspection Report City of Waterloo 715 Mulberry Street, Waterloo, Iowa 50703 PH (319)-291-4319 Fax (319)-291-4262 Inspection Number 753 Inspector* Barry Stratton Re -inspection Date 2/18/2019 Re -inspection # 2 File Upload Property Info Inspection Date* 1/18/2019 Unit Of Street Address:* 1001 Baltimore St Tenant Name: Phone Number: Property Owner Info Property Owner Name: John Dodge Property Owner Email Property Owner Address: Property Owner Phone: Inspection Items 50 W Schrock Rd Waterloo, IA 50701 Item Status Address Posted r Pass r Cond r Fail Siding r Pass r Cond r Fail Roof r Pass 6' Cond r Fail Item Status Porches f Pass f Cond l: Fail Chimney r Pass r Cond F Fail Basement r Pass r Cond F Fail Steps(outside) (Pass (Cond F Fail Foundation (Pass (Cond r Fail Hot Water Heater (Pass (Cond r Fail Heating System r Pass r Cond l: Fail Electric (Pass (Cond F Fail Plumbing r Pass r Cond F Fail Egress (Pass (Cond r Fail Garbage r Pass r Cond r Fail Dining Room r Pass r Cond F Fail Livingroom r Pass r Cond r Fail Bedroom r Pass r Cond F Fail Kitchen (Pass (Cond F Fail Bathe room r Pass r Cond F Fail Appliances (Pass (Cond r Fail Floors (Pass (Cond r Fail Windows -Locks (Pass (Cond r Fail Door -Locks (Pass (Cond F Fail Smoke Detectors r Pass r Cond l: Fail Stairs(Inside) (Pass (Cond F Fail Handrails (Pass (Cond l: Fail Misc. Hazards -list r Pass r Cond F Fail Fire Extinguishers (Pass (Cond F Fail Common Area r Pass r Cond r Fail Attach Photos Comments Violation Comments IFC 907 915 IPMC 704 Smoke detectors are needed in each bedroom and one outside of the bedrooms. Smoke detectors are needed upstairs and in basement. CO detectors needed outside of bedrooms and in upstairs bedroom Violation Comments IPMC 602 Furnace needs replaced. Furnace not able to maintain 68 degrees. Furnace needs done ASAP. Heat runs not supply heat to some areas of the house. IPMC 305 Ceiling leaking in living room and dining room. Find source of leak and repair. Repair damage drywall from water damage. IPMC 605 Electric outlets not grounded. Exhaust fan in bathroom shower will need to be GFCI protected. All outlets and switches will need approved covers installed. Ceiling fan in living room is unsafe. Fixture mounting box is needed for light and wired correctly. IPMC 304.7 IPMC 304.15 IRC 311.3 Porch roof leaking. Ledger not attached correctly and no flashing installed. Back door broken off porch. Exterior doors, assemblies, and hardware needs to be maintained. Side door hardware not functioning as intended. Porch door needs replaced. Landings are required on each side of an exterior door. Landings are needed to be width of door served and 36" inches in direction of travel. IPMC 504 Plumbing fixtures shall be installed and maintained in good condition. Kitchen sink drainage pipe not installed to meet code and will need changed. Bath tub & shower does not have adequate water pressure. IPMC 305 IPMC 403.2 IFC 605.5 IPMC 307 IPMC 304.5 IPMC 304.11 IRC 105 Fees Initial Fees $ Initial Unit $ Additional Units $ Upstairs walls will need drywall installed on areas where missing. Exhaust fan in bathroom shower not GFCI protected. Extension cords in house need removed and multiple adapters are not allowed. Handrails needed to upstairs and basement. Foundation walls leaking. Foundation shall be free from cracks and breaks and shall be kept in sound condition,. Squirrels are getting into basement through clean outs on chimney. All electrical, mechanical, and plumbing shall be done by license contractors licensed to do work in Waterloo, Common Area $ Total Fee* $ 0.00 Does the property C No a Yes require another inspection? Time 9:30