HomeMy WebLinkAbout1106 W 3rd St # 1-Rental Property Inspection-7/24/2019Rental Property Inspection Report City of Waterloo 715 Mulberry Street, Waterloo, Iowa 50703 PH (319)-291-4319 Fax (319)-291-4262 Inspection Number 845 Inspector* Barry Stratton Re -inspection Date 8/26/2019 Re -inspection # 2 File Upload Property Info Inspection Date* 7/24/2019 Unit Of Street Address:* 1106 W 3rd St # 1 Tenant Name: Phone Number: Property Owner Info Property Owner Name: Quality Concrete Construction INC Property Owner Email Property Owner Address: 1930 Hawthorne Ave # 1 Waterloo, IA 50702 Property Owner Phone: 319-231-0170 Inspection Items Item Status Address Posted r Pass r Cond f Fail Siding r Pass r Cond (Fail Roof r Pass r Cond (Fail Porches C Pass f Cond C•' Fail Chimney C Pass (Cond r Fail Basement C Pass (Cond C•' Fail Steps(outside) 0 Pass (Cond C•' Fail Foundation 0 Pass C Cond r Fail Hot Water Heater 0 Pass 0 Cond r Fail Heating System C Pass 0 Cond r Fail Electric C Pass 0 Cond (' Fail Plumbing 0 Pass n Cond r Fail Egress 0 Pass (Cond C•' Fail Garbage 0 Pass (Cond C•' Fail Dining Room C Pass (Cond r Fail Livingroom C Pass (Cond r Fail Bedroom 0 Pass 0 Cond r Fail Kitchen 0 Pass 0 Cond r Fail Bathe room 0 Pass 0 Cond C•' Fail Appliances ( Pass (Cond r Fail Floors (Pass (Cond C•' Fail Windows -Locks (Pass (Cond C•' Fail Door -Locks C Pass (Cond C•' Fail Smoke Detectors 0 Pass (Cond C•' Fail Stairs(Inside) 0 Pass 0 Cond r Fail Handrails C Pass 0 Cond C' Fail Misc. Hazards -list C Pass (Cond C' Fail Fire Extinguishers 0 Pass 0 Cond C' Fail Common Area 0 Pass 0 Cond r Fail Attach Photos Comments Violation Comments IFC 907 915 IPMC 704 Smoke detectors needed in each bedroom and outside of the bedrooms. Smoke detector is needed in basement. CO detectors needed in vicinity of the bedrooms. IFC 906 Updated fire extinguisher is needed in unit. IPMC 603 Refrigerator is not working and will need replaced. IPMC 305 Peeling and abraded paint will need corrected in unit. Bathroom walls and components around shower and tub not maintained. IPMC 306 Kitchen cabinets shall be maintained in good condition. Missing drawer fronts and doors. IPMC 305.6 Interior doors need repaired. Doors off hinges and doors missing trim. Also doors need hardware and capable of preforming their intended function. IPMC 605 Switched and outlets need approved covers. All outlets need to be in working condition. Kitchen GFCI not working and outlet in bedroom has burn damage. IPMC 403.5 Dryer exhaust needs to be exhausted to the outside. IPMC 304.12 Handrails needed to basement. Handrails are needed on both sections of the steps to the unit on the exterior. IPMC 702 A safe continuous and unobstructed path of travel shall be provided from any point of the structure to the public way. Door in bedroom is not functional for egress. IPMC 305.4 IPMC 304.10 Fees Initial Fees $ Initial Unit $ Additional Units $ Common Area $ Total Fee* $ 0.00 Does the property r No C' Yes require another inspection? Time 10:00 Kitchen and living room floors not maintained and shall be replaced. Every floor shall be maintained in good repair and sound condition. Front door porch shall be maintained structurally sound, in good repair, and capable of supporting all imposed loads. Guards and railings not safe.