HomeMy WebLinkAbout1436 Ansborough Ave-Rental Property Inspection-7/15/2019 Rental Property Inspection Report
City of Waterloo
715 Mulberry Street,
Waterloo, Iowa 50703
PH(319)-291-4319 Fax(319)-291-4262
Inspection Number 828
Inspector* Barry Stratton
Re-inspection Date 8/12/2019
Re-inspection# 2
File Upload
Property Info
Inspection Date* 7/15/2019
Unit Of
Street Address:* 1436 Ansborough Ave
Tenant Name:
Phone Number:
Property Owner Info
Property Owner Name: Dustin Cox
Property Owner
Email
Property Owner 9725 Sylvan Dr Janesville, IA 50647
Address:
Property Owner Phone:
Inspection Items
Item Status
Address Posted r Pass r Cond f Fail
Siding r Pass r Cond (Fail
Roof r Pass r Cond r Fail
Porches r Pass f Cond r Fail
Chimney r Pass C Cond r Fail
Basement C3 Pass C Cond r Fail
Steps(outside) O Pass C Cond r Fail
Foundation O Pass C3 Cond r Fail
Hot Water Heater C5 Pass 0 Cond r Fail
Heating System C3 Pass 0 Cond r Fail
Electric C3 Pass 0 Cond r Fail
Plumbing O Pass n Cond r Fail
Egress O Pass (Cond r Fail
Garbage C5 Pass (Cond r Fail
Dining Room C3 Pass (Cond f Fail
Livingroom C3 Pass (Cond r Fail
Bedroom O Pass O Cond r Fail
Kitchen O Pass O Cond r Fail
Batheroom C5 Pass O Cond r Fail
Appliances r Pass (Cond r Fail
Floors r Pass (Cond r Fail
Windows-Locks r Pass (Cond r Fail
Door-Locks C3 Pass (Cond r Fail
Smoke Detectors O Pass (Cond r Fail
Stairs(Inside) C5 Pass O Cond (Fail
Handrails r Pass r Cond r Fail
Misc. Hazards-list C Pass C Cond r Fail
Fire Extinguishers O Pass r Cond r Fail
Common Area O Pass O Cond r Fail
Attach Photos
Comments
Violation Comments
IFC 907 915 IPMC 704 Smoke detectors are needed in bedrooms,outside
of bedrooms,and in basement. CO detector is
needed in vicinity of bedrooms.
IPMC 304.13 Window in bathroom needs replaced with a
tempered window that meets code. Currently window
and frame not maintained in sound condition,good
repair and weather tight.
IPMC 605 Electric outlet in living room does not work.
All light fixtures shall have proper globes installed in
all lights.
IPMC 504 Toilet needs reset on floor.
Water heater installed does not meet code and was
installed with out permits.WH is also missing
discharge tube. Draft tube not attached to WH.WH
manufactured Apr 2018.
Sanitary waste line on bathtub not installed to code,
Currently has an S trap and this is not allowed.
IPMC 30.4.7 Roof is leaking into house. Basement is wet and
bedroom ceiling is wet from water damage. Roof
drainage shall be adequate to prevent dampness or
deterioration in the walls or interior portion of the
structure.
IPMC 305 Potential mold growth in basement entryway and
bathroom window. Mitigation shall be done to remove
mold growth from house.
Ceiling in living room is missing ceiling tile.
IPMC 305.2&305.4 Bathroom floor has floor damage with holes in floor.
Sub floor needs replaced and new tiles installed over
sub floor. Structural members shall be maintained
structurally sound and capable of supporting the
imposed loads.
IPMC 108.1.3 Currently structure is unfit to occupy. Unit is unsafe,
insanitary,and other noted violations constitute a
hazard to the occupants of the structure.
Fees
Initial Fees $
Initial Unit $
Additional Units $
Common Area $
Total Fee* $ 0.00
Does the property r No r Yes
require another
inspection?
Time 1:00