Loading...
HomeMy WebLinkAbout1250 Meadow Ln # C-Rental Property Inspection-6/27/2019 Rental Property Inspection Report City of Waterloo 715 Mulberry Street, Waterloo, Iowa 50703 PH(319)-291-4319 Fax(319)-291-4262 Inspection Number 823 Inspector* Barry Stratton Re-inspection Date 7/29/2019 Re-inspection# 2 File Upload Property Info Inspection Date* 6/27/2019 Unit Of Street Address:* 1250 Meadow Ln#C Tenant Name: Phone Number: Property Owner Info Property Owner Name: 30 Something Real Estate LLC Property Owner Email Property Owner Po Box 56 Waterloo, IA 50704 Address: Property Owner Phone: 319-296-8106 Inspection Items Item Status Address Posted r Pass r Cond f Fail Siding r Pass r Cond (Fail Roof r Pass r Cond (Fail Porches r Pass f Cond r Fail Chimney r Pass C Cond r Fail Basement C3 Pass C Cond r Fail Steps(outside) O Pass C Cond r Fail Foundation O Pass C3 Cond r Fail Hot Water Heater C5 Pass 0 Cond a Fail Heating System C3 Pass 0 Cond F Fail Electric C3 Pass 0 Cond r Fail Plumbing O Pass n Cond r Fail Egress O Pass (Cond r Fail Garbage C5 Pass (Cond r Fail Dining Room C3 Pass (Cond f Fail Livingroom C3 Pass (Cond r Fail Bedroom O Pass O Cond r Fail Kitchen O Pass O Cond r Fail Batheroom C5 Pass O Cond r Fail Appliances r Pass (Cond r Fail Floors r Pass (Cond r Fail Windows-Locks r Pass (Cond r Fail Door-Locks C3 Pass (Cond r Fail Smoke Detectors O Pass (Cond r Fail Stairs(Inside) C5 Pass O Cond (Fail Handrails r Pass r Cond r Fail Misc. Hazards-list C Pass C Cond r Fail Fire Extinguishers O Pass r Cond r Fail Common Area O Pass O Cond r Fail Attach Photos Comments Violation Comments IFC 907 915 IPMC 704 Smoke detectors are needed in each bedroom and outside of the bedrooms.CO detectors are needed in vicinity of the bedrooms. IPMC 504 Water heater supply lines not installed to code. Draft hood not secure. Brown water coming out of faucets in unit. Sewer gas smell in unit. Licensed plumber needs to correct all issues within building. Sewer gas smell in building and unit. Water heaters were installed without permits and inspections in both units. Richmond water heaters manufactured in 2014. IPMC 403.2 Bath exhaust not working and needs replaced. IPMC 603 Furnace filter needs changed and register needs cleaned. AC unit not working in unit. Mechanical equipment shall be maintained in a safe working condition and capable of preforming its intended function. Common Areas IPMC 305 Flooring needs replaced at main&rear entrance doors. IFC 906 Need updated fire extinguishers in building. IBC 716 All fire doors need to remain closed and latched. Install hinges to maintain doors closures so they close and latch. IFC 506 Key boxes needed on secured buildings. Fees Initial Fees $ Initial Unit $ Additional Units $ Common Area $ Total Fee* $ 0.00 Does the property r No r Yes require another inspection? Time 1:30