HomeMy WebLinkAbout1250 Meadow Ln # H-Rental Property Inspection-6/27/2019 Rental Property Inspection Report City of Waterloo 715 Mulberry Street, Waterloo, Iowa 50703 PH(319)-291-4319 Fax(319)-291-4262 Inspection Number 822 Inspector* Barry Stratton Re-inspection Date 7/29/2019 Re-inspection# 2 File Upload Property Info Inspection Date* 6/27/2019 Unit Of Street Address:* 1250 Meadow Ln#H Tenant Name: Phone Number: Property Owner Info Property Owner Name: 30 Something Real Estate LLC Property Owner Email Property Owner Po Box 56 Waterloo, IA 50704 Address: Property Owner Phone: 319-296-8106 Inspection Items Item Status Address Posted r Pass r Cond f Fail Siding r Pass r Cond (Fail Roof r Pass r Cond (Fail Porches r Pass f Cond r Fail Chimney r Pass C Cond r Fail Basement C3 Pass C Cond r Fail Steps(outside) O Pass C Cond r Fail Foundation O Pass C3 Cond r Fail Hot Water Heater C5 Pass 0 Cond a Fail Heating System C3 Pass 0 Cond F Fail Electric C3 Pass 0 Cond r Fail Plumbing O Pass n Cond r Fail Egress O Pass (Cond r Fail Garbage C5 Pass (Cond r Fail Dining Room C3 Pass (Cond f Fail Livingroom C3 Pass (Cond r Fail Bedroom O Pass O Cond r Fail Kitchen O Pass O Cond r Fail Batheroom C5 Pass O Cond r Fail Appliances r Pass (Cond r Fail Floors r Pass (Cond r Fail Windows-Locks r Pass (Cond r Fail Door-Locks C3 Pass (Cond r Fail Smoke Detectors O Pass (Cond r Fail Stairs(Inside) C5 Pass O Cond (Fail Handrails r Pass r Cond r Fail Misc. Hazards-list C Pass C Cond r Fail Fire Extinguishers O Pass r Cond r Fail Common Area O Pass O Cond r Fail Attach Photos Comments Violation Comments IFC907 915 IPMC 704 Smoke detectors are needed in every bedroom and outside of the bedrooms.CO detectors are needed in vicinity of the bedrooms. IPMC 504 Water heater not installed to code. Supply lines need corrected and draft hood not secured. Sewer line is broken and needs fixed. Brown water coming out of fixtures.Toilet and tub not draining properly. Kitchen sink needs newfaucet. Contact licensed plumber to correct issues within building. IPMC 603 Register returned need cleaned and furnace needs new filter. IPMC 403.4 Sewer gas smell in unit.Where toxic, irritating,or noxious fumes are generated it shall be abated. IPMC 304.13 Front window leaks and needs repaired. Common Areas IFC 906 Updated fire extinguishers needed in building. (January 2017) IBC 716 All fire doors shall remain closed at all times. Install hinges on doors so they will close and latch. Egress doors also need to close and latch. IPMC 305 Flooring at main egress door&rear egress door needs replaced. IPMC 309.4 General infestation needs to be maintained by the owner. Unit H potential of bed bugs in units. Occupants have bites on their person from bug bites. IFC 506 Key boxes are required to be installed because access is restricted.Where immediate life-saving or fire-fighting purposes are necessary knox boxes are required. Fees Initial Fees $ Initial Unit $ Additional Units $ Common Area $ Total Fee* $ 0.00 Does the property r No r Yes require another inspection? Time 1:30