HomeMy WebLinkAbout537 Courtland St-Rental Property Inspection-6/18/2019 Rental Property Inspection Report City of Waterloo 715 Mulberry Street, Waterloo, Iowa 50703 PH(319)-291-4319 Fax(319)-291-4262 Inspection Number 817 Inspector* Barry Stratton Re-inspection Date 7/18/2019 Re-inspection# 2 File Upload Property Info Inspection Date* 6/18/2019 Unit Of Street Address:* 537 Courtland St Tenant Name: Phone Number: Property Owner Info Property Owner Name: Richard Kaough/Martin Realtors Property Owner Email Property Owner 7800 3rd Ave S St. Petersburg, FL 33707 Address: Property Owner Phone: Inspection Items Item Status Address Posted r Pass r Cond f Fail Siding r Pass r Cond (Fail Roof r Pass r Cond (Fail Porches r Pass f Cond r Fail Chimney r Pass C Cond r Fail Basement C3 Pass C Cond r Fail Steps(outside) O Pass C Cond r Fail Foundation O Pass C3 Cond r Fail Hot Water Heater C5 Pass 0 Cond r Fail Heating System C3 Pass 0 Cond F Fail Electric C3 Pass 0 Cond r Fail Plumbing O Pass n Cond r Fail Egress O Pass (Cond r Fail Garbage C5 Pass (Cond r Fail Dining Room C3 Pass (Cond f Fail Livingroom C3 Pass (Cond r Fail Bedroom O Pass O Cond r Fail Kitchen O Pass O Cond r Fail Batheroom C5 Pass O Cond r Fail Appliances r Pass (Cond r Fail Floors r Pass (Cond r Fail Windows-Locks r Pass (Cond r Fail Door-Locks C3 Pass (Cond r Fail Smoke Detectors O Pass (Cond r Fail Stairs(Inside) C5 Pass O Cond (Fail Handrails r Pass r Cond r Fail Misc. Hazards-list C Pass C Cond r Fail Fire Extinguishers O Pass r Cond r Fail Common Area O Pass O Cond r Fail Attach Photos Comments Violation Comments IFC 907 915 IPMC 704 Smoke detectors needed in each bedroom and one outside of the bedrooms.CO detector is needed in vicinity of the bedrooms.Smoke detector is needed in basement and in attic. 9-7-49-7-5 Landlord license and rental registration is needed for 2019 IPMC 304.10 Front steps to house are rocking and not maintained structurally sound and in good repair. IPMC 305 Flooring on inside of porch needs replaced. Boards are rotten and not in good shape. Floors in basement are wet from water getting into basement. Flooring under bathroom in basement has water damage and needs replaced. Correct all peeling missing, and abraded paint. Need transition strips and carpet needs replaced. IPMC 504 Bathroom sink faucet needs replaced.A odor is coming from drain possible not vented correctly. Sump Pump installed connected to sanitary sewer and needs installed to code. Washer drain stack draining into sump pump and needs installed to sanitary. IPMC 605 Electric cord running sump pump and pump needs direct connection to outlet. Grounding strap not installed on water meter. 220 V dryer wire needs stapled to floor joist. Light on rear of house is not working. IPMC 304.5 Foundation is leaking water into basement.Walls shall be free from cracks&holes and not have defects that admit rain. Spray foam is not structural to fix holes.Appearance of mold on foundation walls. IPMC 304.15 All doors shall be maintained in good condition and able to preform their intended function. Door assemblies and hardware need to be in goo condition. IPMC 304.7 Gutters are broken and leaking around house. Potentially adding to water problem in basement. IPMC 304.13 All windows need to close and latch. Repair all broken glass and windows. IPMC 602 Amana furnace and central AC installed with out permits&inspections. Contact licensed HVAC to get permits&inspection to ensure installed to manufactures specifications&code. IPMC 403.5 Dryer is venting in basement and needs to vent to the exterior of the home. Fees Initial Fees $ 50.00 Initial Unit $ Additional Units $ Common Area $ Total Fee* $ 50.00 Does the property r No a Yes require another inspection? Time 1:30