HomeMy WebLinkAbout808 Conger St-Rental Property Inspection-4/16/2018 Rental Property Inspection Report City of Waterloo 715 Mulberry Street, Waterloo, Iowa 50703 PH(319)-291-4319 Fax(319)-291-4262 Inspection Number 602 Inspector* Barry Stratton Re-inspection Date 5/14/2018 Re-inspection# 2 File Upload Property Info Inspection Date* 4/16/2018 Unit Of Street Address:* 808 Conger St Tenant Name: Phone Number: Property Owner Info Property Owner Name: Dustin Cox Property Owner Email Property Owner 1125 Virginia St Waterloo, IA 50703 Address: Property Owner Phone: Inspection Items Item Status Address Posted r Pass r Cond r Fail Siding r Pass r Cond r Fail Roof r Pass r Cond r Fail Item Status Porches f Pass f Cond r Fail Chimney r Pass r Cond r Fail Basement r Pass r Cond F Fail Steps(outside) (Pass f Cond r Fail Foundation (Pass f Cond F Fail Hot Water Heater (Pass f Cond r Fail Heating System r Pass r Cond r Fail Electric (Pass f Cond F Fail Plumbing r Pass r Cond F Fail Egress (Pass f Cond F Fail Garbage r Pass r Cond r Fail Dining Room r Pass r Cond r Fail Livingroom r Pass r Cond r Fail Bedroom r Pass r Cond F Fail Kitchen (Pass f Cond F Fail Batheroom r Pass r Cond F Fail Appliances (Pass f Cond F Fail Floors (Pass f Cond r Fail Windows-Locks (Pass f Cond F Fail Door-Locks (Pass f Cond F Fail Smoke Detectors r Pass r Cond F Fail Stairs(Inside) (Pass f Cond r Fail Handrails (Pass f Cond F Fail Misc. Hazards-list r Pass r Cond F Fail Fire Extinguishers (Pass f Cond F Fail Common Area r Pass r Cond r Fail Attach Photos Comments Violation Comments IFC 907 915 IPMC 704 Smoke detectors needed in each bedroom and outside of the bedrooms. Smoke detector needed in basement and on each level. CO detectors needed in vicinity of any bedroom. Violation Comments IPMC 304.13 Every window and frame shall be kept in sound condition,good repair and weather tight. Broken glass shall be replaced. Glass shall be glazed in its opening to code.Windows shall function and shall be easily op enable and capable of being held in the position by the window hardware. Window in stairwell, bathroom window and windows on porch need corrected.Windows through out the house needs looked at. Window frames shall be maintained in good condition in house and on porch. IPMC 304.15 All doors and hardware shall be maintained in good condition. Locks and hardware shall tightly secure the door. Entrance doors and door jams need replaced. Side entrance door is missing a hinge. Interior doors shall function as manufactured. Front, side, and rear doors need replaced. Windows in doors shall be replaced. Nails used in doors shall be removed for fear of causing injury to occupants. IPMC 305 All peeling and abraded paint shall be corrected. Walls shall be maintained in good,clean,and sanitary condition. Bath floor shall be maintained good condition. Bedroom ceiling and bathroom ceiling have water damage from some type of leak. IPMC 504 Tub surround is coming loose and needs replaced. Bathroom sink has no water pressure and will need corrected. Drain in basement is backed up and will need repaired. IPMC 307 Missing handrail to basement. IPMC 605 Electric panel is unsafe and potential to cause injury when changing fuses. Outlets through out house need grounded. Check electric system to ensure safety. All switches shall function as intended. Switches are broken and need replaced.All outlets need to be in working condition. IPMC 702 Egress path blocked to side door and to basement. IPMC 304.5 Foundation walls shall be free from holes and breaks.Walls are leaking water into basement. IPMC 603 Stove in not functioning as manufactured and needs repaired or replaced. IFC 315 General storage in basement need T clearance around mechanical appliances and electric panel. Fees Initial Fees $ Initial Unit $ Additional Units $ Common Area $ Total Fee* $ 0.00 Does the property r, No d Yes require another inspection? Time 12:30