HomeMy WebLinkAbout402 Sullivan Ave # 1 Basement-Rental Property Inspection-3/22/2018 Rental Property Inspection Report
City of Waterloo
715 Mulberry Street,
Waterloo, Iowa 50703
PH(319)-291-4319 Fax(319)-291-4262
Inspection Number 597
Inspector* Barry Stratton
Re-inspection Date 4/19/2018
Re-inspection# 2
File Upload
Property Info
Inspection Date* 3/22/2018
Unit Of
Street Address:* 402 Sullivan Ave#1 Basement
Tenant Name:
Phone Number:
Property Owner Info
Property Owner Name: Greg&Constance Lamph ire
Property Owner
Email
Property Owner 9024 Glenbrook Rd Hammondsport NY
Address: 14840
Property Owner Phone:
Inspection Items
Item Status
Address Posted r Pass r Cond r Fail
Siding r Pass r Cond r Fail
Roof r Pass r Cond r Fail
Item Status
Porches f Pass f Cond r Fail
Chimney r Pass r Cond r Fail
Basement r Pass r Cond F Fail
Steps(outside) (Pass f Cond r Fail
Foundation (Pass f Cond r Fail
Hot Water Heater (Pass f Cond F Fail
Heating System r Pass r Cond r Fail
Electric (Pass f Cond F Fail
Plumbing r Pass r Cond F Fail
Egress (Pass f Cond F Fail
Garbage r Pass r Cond r Fail
Dining Room r Pass r Cond r Fail
Livingroom r Pass r Cond r Fail
Bedroom r Pass r Cond F Fail
Kitchen (Pass f Cond r Fail
Batheroom r Pass r Cond r Fail
Appliances (Pass f Cond r Fail
Floors (Pass f Cond F Fail
Windows-Locks (Pass f Cond F Fail
Door-Locks (Pass f Cond F Fail
Smoke Detectors r Pass r Cond F Fail
Stairs(Inside) (Pass f Cond r Fail
Handrails (Pass f Cond r Fail
Misc. Hazards-list r Pass r Cond F Fail
Fire Extinguishers (Pass f Cond F Fail
Common Area r Pass r Cond r Fail
Attach Photos
Comments
Violation Comments
IFC 907 915 IPMC 704 Smoke detectors needed in bedroom and outside of
the bedrooms. CO detectors needed installed by
bedrooms.
Smoke detectors needed in basement.
Violation Comments
IPMC 605 Electric outlets are wired wrong. Hot/neutral
reversed.
Outlets missing covers.
Electric conduit is hanging in basement and not
secured to wall.
220 V dryer outlet also not secured to wall.
Outlets in basement not working.
All light fixtures will need globes/covers installed
that are missing.
Light in stairway to lower unit is missing. Egress path
needs to be illuminated.
IFC 605.5 Multiple adapters are in use and not allowed.
Adapters need removed.
IPMC 504 Water heaters need attention. Draft hood on one of
the water heaters not secured over exhaust port.
One water heater is missing draft tube.
Discontinued Pex in basement needs removed.
Pumping water from basement needs to stop and
have sanitary drain checked by licensed plumber to
ensure system if functioning to code.
IPMC 305 Floors and walking surfaces need to be maintained
in good, clean and sanitary condition. Floors are
loose and not in good condition.
IPMC 702 Means of egress. No egress window in the bedroom.
Egress window that is in the living room is not
installed to code. Make corrections so rental unit
meets code for means of egress.
Have window removed/replaced so it meets code.
Past inspections on window have failed.
IPMC 304.15 Apartment entrance door not installed to code.All
doors and assemblies, door hardware shall be
maintained in good condition. Door Jam needs
installed to meet code.
IPMC 304.16 Basement egress window is leaking. Every hatchway
/window shall be maintained to prevent the entrance
of rain and surface drainage water.