Loading...
HomeMy WebLinkAbout807 1/2 W 3rd St-Rental Property Inspection-3/1/2018 Rental Property Inspection Report City of Waterloo 715 Mulberry Street, Waterloo, Iowa 50703 PH(319)-291-4319 Fax(319)-291-4262 Inspection Number 580 Inspector* Barry Stratton Re-inspection Date 4/2/2018 Re-inspection# 6 File Upload Property Info Inspection Date* 3/1/2018 Unit Of Street Address:* 807 1/2 W 3rd St Tenant Name: Phone Number: Property Owner Info Property Owner Name: Roger Knebel Property Owner Email Property Owner 2576 Independence Ave Waterloo, IA 50707 Address: Property Owner Phone: Inspection Items Item Status Address Posted r Pass r Cond r Fail Siding r Pass r Cond r Fail Roof r Pass r Cond r Fail Item Status Porches f Pass f Cond r Fail Chimney r Pass r Cond r Fail Basement r Pass r Cond r Fail Steps(outside) (Pass f Cond F Fail Foundation (Pass f Cond r Fail Hot Water Heater (Pass f Cond r Fail Heating System r Pass r Cond r Fail Electric (Pass f Cond F Fail Plumbing r Pass r Cond F Fail Egress (Pass f Cond F Fail Garbage r Pass r Cond r Fail Dining Room r Pass r Cond r Fail Livingroom r Pass r Cond r Fail Bedroom r Pass r Cond r Fail Kitchen (Pass f Cond F Fail Batheroom r Pass r Cond F Fail Appliances (Pass f Cond F Fail Floors (Pass f Cond F Fail Windows-Locks (Pass f Cond F Fail Door-Locks (Pass f Cond F Fail Smoke Detectors r Pass r Cond F Fail Stairs(Inside) (Pass f Cond r Fail Handrails (Pass f Cond F Fail Misc. Hazards-list r Pass r Cond F Fail Fire Extinguishers (Pass f Cond F Fail Common Area r Pass r Cond r Fail Attach Photos Comments Violation Comments IFC 907 915 IPMC 704 Need smoke detectors and o detectors installed to code. Smoke detector in each bedrooms and 1 outside of the bedrooms. CO detector installed in vicinity of the bedrooms. Violation Comments IPMC 304.10 Stairs, handrails, guards,to upper unit needs removed and replaced. Exposed nails and very unstable rails and steps. Missing steps and guards are dangerous. IFC 605.5 Remove ALL extension cords. IPMC 605 Several electrical issues throughout the unit. Outlets missing covers,outlets pulling out of the walls and fan hanging on wall in bedroom is unsafe.All lights need globes and installed to code.All fixtures need covers.All lights need to be in working condition. IPMC 603 Refrigerator was not working at time of initial inspection. Thermostat was hanging from wall. IPMC 305 Ceiling tiles missing.All paneling shall be attached to the walls and maintained sound and capable of supporting all imposed loads. Floor in front bedroom is slopped severally and all structural members need checked to ensure all imposed loads are safe. IPMC 403.2 Need to install bath exhaust fan in bathroom that is is operating condition. IPMC 304.15 Doors need to be in functional condition and in good repair. IPMC109 Imminent danger Electrical system is currently unsafe to the occupants. IPMC 108.1.5 Unsafe deck, stairs, and walking surfaces currently in place.The current walking surface and stairs are unsafe and do not provide proper exit or other safe means of egress. There is faulty construction and is likely to partially or completely collapse. . Fees Initial Fees $ Initial Unit $ Additional Units $ Common Area $ Total Fee* $ 0.00 Does the property r No F Yes require another inspection? Time 9:00