HomeMy WebLinkAbout415 E 8th St # 3-Rental Property Inspection-11/13/2018 Rental Property Inspection Report
City of Waterloo
715 Mulberry Street,
Waterloo, Iowa 50703
PH(319)-291-4319 Fax(319)-291-4262
Inspection Number 715
Inspector* Barry Stratton
Re-inspection Date 12/11/2018
Re-inspection# 3
File Upload
Property Info
Inspection Date* 11/13/2018
Unit Of
Street Address:* 415 E 8th St#3
Tenant Name:
Phone Number:
Property Owner Info
Property Owner Name: Jeremiah&Keri Jacobson
Property Owner
Email
Property Owner 3941 Scenic Dr Waterloo, IA 50701
Address:
Property Owner Phone:
Inspection Items
Item Status
Address Posted r Pass r Cond r Fail
Siding r Pass r Cond r Fail
Roof r Pass r Cond r Fail
Item Status
Porches C Pass C Cond f•Fail
Chimney C Pass C Cond (Fail
Basement C Pass C; Cond f•Fail
Steps(outside) C Pass C Cond f•Fail
Foundation C Pass C Cond f•Fail
Hot Water Heater C Pass C Cond (Fail
Heating System O Pass O Cond f•Fail
Electric a Pass C Cond f•Fail
Plumbing a Pass C Cond (Fail
Egress C Pass C Cond f•Fail
Garbage C Pass C Cond (Fail
Dining Room C Pass C Cond (Fail
Livingroom O Pass C) Cond C Fail
Bedroom O Pass C Cond F Fail
Kitchen C Pass C Cond (Fail
Batheroom C Pass C` Cond (Fail
Appliances C Pass C Cond (Fail
Floors f Pass r) Cond (Fail
Windows-Locks C Pass C Cond F Fail
Door-Locks C Pass C Cond f•Fail
Smoke Detectors C Pass r Cond f•Fail
Stairs(Inside) C Pass r Cond (Fail
Handrails C Pass r Cond f•Fail
Misc. Hazards-list C Pass C Cond f•Fail
Fire Extinguishers C Pass C Cond f•Fail
Common Area C Pass C Cond (Fail
Attach Photos
Comments
Violation Comments
IFC 907 915 IPMC 704 Smoke detectors need to be installed to meet code.
CO detectors also need to be installed to meet code.
Violation Comments
IPMC 304.10 Back stairs and handrail unsafe and still need to be
corrected. Back enclosure still not corrected &made
safe.Walls and roof system not capable of
supporting the imposed loads.
IPMC 304.15 Entrance door needs to be weather tight.
IPMC 304.13 Windows&frames shall be kept in sound condition,
good repair and weather tight. Framing around
windows is rotten and needs to be re-framed.
Windows in structure shall be replaced.
IPMC 305.6 Interior doors will need to be replaced.
IPMC 605 Outlet in living room is not grounded.
IPMC 602.3 Furnace is not capable of heating unit to meet code.
Tenants were heating unit with the stove. Mechanical
equipment shall be installed and maintained in safe
working condition.
IPMC 304.5 Foundation walls shall be maintained ion good
condition, plumb and free from open cracks.
IPMC 304.2 Exterior treatment shall be maintained water tight
and weather resistant. Slate siding is decayed and
not secured to structure.
IPMC 402 Egress door outside unit#3 shall provide sufficient
lighting to permit the safe entry to building.
IPMC 302.3 Walks and driveways shall be kept in a proper state
of repair and maintained free from hazardous
conditions. Large holes in rear of property need
attention.
IPMC 108.1.1 Unsafe conditions exist with the condition of the
porch on rear of house to unit#3.
Fees
Initial Fees $ 50.00
Initial Unit $
Additional Units $
Common Area $
Total Fee* $ 50.00
Does the property f No r Yes
require another
inspection?
Time 1:00