Loading...
HomeMy WebLinkAbout826 W 1st St-Rental Property Inspection-11/8/2018 Rental Property Inspection Report City of Waterloo 715 Mulberry Street, Waterloo, Iowa 50703 PH(319)-291-4319 Fax(319)-291-4262 Inspection Number 713 Inspector* Barry Stratton Re-inspection Date 12/10/2018 Re-inspection# 3 File Upload Property Info Inspection Date* 11/8/2018 Unit Of Street Address:* 826 W 1st St Tenant Name: Phone Number: Property Owner Info Property Owner Name: Roy Odell INC/Mary Leahy Property Owner Email Property Owner 321 Elmside Bd Madison,WI 53704 Address: Property Owner Phone: Inspection Items Item Status Address Posted r Pass r Cond r Fail Siding r Pass r Cond r Fail Roof r Pass r Cond r Fail Item Status Porches f Pass f Cond r Fail Chimney r Pass r Cond F Fail Basement r Pass r Cond F Fail Steps(outside) (Pass f Cond r Fail Foundation (Pass f Cond r Fail Hot Water Heater (Pass f Cond r Fail Heating System r Pass r Cond r Fail Electric (Pass f Cond F Fail Plumbing r Pass r Cond F Fail Egress (Pass f Cond F Fail Garbage r Pass r Cond F Fail Dining Room r Pass r Cond r Fail Livingroom r Pass r Cond r Fail Bedroom r Pass r Cond F Fail Kitchen (Pass f Cond F Fail Batheroom r Pass r Cond F Fail Appliances (Pass f Cond F Fail Floors (Pass f Cond F Fail Windows-Locks (Pass f Cond F Fail Door-Locks (Pass f Cond F Fail Smoke Detectors r Pass r Cond F Fail Stairs(Inside) (Pass f Cond r Fail Handrails (Pass f Cond F Fail Misc. Hazards-list r Pass r Cond F Fail Fire Extinguishers (Pass f Cond F Fail Common Area r Pass r Cond F Fail Attach Photos Comments Violation Comments IFC 907 915 IPMC 704 Smoke detectors needed in every bedroom and outside of the bedrooms. Smoke detector is needed on every level and in basement. CO detectors are needed in vicinity of the bedrooms. Violation Comments Zoning Code 10-10-1 (A) 10 Alterations and conversions of a single family dwelling into a rooming house will require a special permit by the BOA. Single family house is being use as a rooming house. Rooms are being rented to individuals for money per room. IPMC 605 Porch light needs to be wired to code. Panel in basement is missing cover. Lights are missing globes. Outlets and switches need approved covers. Electric service is off at listed address. IPMC 504 Basement flooded and standing water is in basement.Water is not currently on at listed address. Fixtures do not work as intended. Plumbing fixtures shall be properly installed and maintained. IPMC 305 Holes in walls,floors,and ceilings shall be repaired. IPMC 304.7 Roof leaking and causing damage in the interior of the home. Gutters are full of debris and need cleaned. IPMC 702 Egress paths blocked in house. Back door screwed shut. Debris throughout the house blocking egress paths. Sleeping in basement with an egress window. IPMC 304.13 Broken windows still not repaired. IPMC 305.6 Doors will need to be maintained in good condition. Locks and hardware need to be in working condition Clasp locks not allowed and need removed immediately. IPMC 307 Handrails needed throughout the house and exterior porches and exits. IPMC 108.1.3 Structure is unfit to occupy.The structure constitutes a hazard to all the occupants of the structure and public.All utilities shall be in service in house or house will need to be vacated. 9-7-49-7-5 Landlord license and rental registration is still not be obtained. IPMC 108.1.1 Unsafe structure is one that is found to be dangerous to life, health, property or safety of the occupants. IPMC 109 Imminent danger exists with all the deficiencies with the condition of the house. IPMC 106.5 Failure to comply with the notice abatement proceedings will start citations being issued. Fees Initial Fees $ 50.00 Initial Unit $ Additional Units $ Common Area $ Total Fee* $ 50.00 Does the property r No r Yes require another inspection? Time 10:30