HomeMy WebLinkAbout317 Riehl St-Rental Property Inspection-10/9/2018 Rental Property Inspection Report
City of Waterloo
715 Mulberry Street,
Waterloo, Iowa 50703
PH(319)-291-4319 Fax(319)-291-4262
Inspection Number 688
Inspector* Barry Stratton
Re-inspection Date 11/7/2018
Re-inspection# 2
File Upload
Property Info
Inspection Date* 10/9/2018
Unit Of
Street Address:* 317 Riehl St
Tenant Name:
Phone Number:
Property Owner Info
Property Owner Name: Allen Frost
Property Owner
Email
Property Owner 3951 Wagner Rd Waterloo, IA 50703
Address:
Property Owner Phone:
Inspection Items
Item Status
Address Posted r Pass r Cond r Fail
Siding r Pass r Cond r Fail
Roof r Pass r Cond r Fail
Item Status
Porches C Pass C Cond f Fail
Chimney C Pass C Cond (Fail
Basement C Pass C; Cond f•Fail
Steps(outside) C Pass C Cond (Fail
Foundation C Pass C Cond f•Fail
Hot Water Heater C Pass C Cond f•Fail
Heating System O Pass O Cond (Fail
Electric a Pass C Cond f•Fail
Plumbing a Pass C Cond (Fail
Egress C Pass C Cond f•Fail
Garbage C Pass C Cond (Fail
Dining Room C Pass C Cond (Fail
Livingroom O Pass C) Cond f• Fail
Bedroom O Pass C Cond (Fail
Kitchen C Pass C Cond (Fail
Batheroom C Pass C` Cond (Fail
Appliances C Pass C Cond (Fail
Floors f Pass r) Cond (Fail
Windows-Locks C Pass C Cond F Fail
Door-Locks C Pass C Cond f•Fail
Smoke Detectors C Pass r Cond f•Fail
Stairs(Inside) C Pass r Cond (Fail
Handrails C Pass r Cond (Fail
Misc. Hazards-list C Pass C Cond F Fail
Fire Extinguishers C Pass C Cond f•Fail
Common Area C Pass C Cond (Fail
Attach Photos
Comments
Violation Comments
IFC907 915 IPMC 704 Smoke detectors need to be in working condition.
Girls bedroom smoke detector is not working.
Violation Comments
IPMC 309 Rodent infestation(mice)in unit. Proper
extermination by an approved processes shall be
done to keep unit free of infestation.
IPMC 304.13 All broken windows shall be fixed.All windows shall
be kept in sound condition, good repair,.and
weather tight.
IPMC 304.7 Open sofit and gutters damaged shall be repaired
IPMC 304.15 Exterior doors, door assemblies,operator systems
shall be maintained in good condition. Rear screen
door broken,front door needs weather striping, and
porch door needs door trim around inside of door.
All exterior doors will need to be weather tight.
IRC 311.3 Need a landing on each side of an exterior door.
Back door will need a 36"inch landing in measured
in the direction of travel to the exterior of the house.
IPMC 504 Water heater will need a discharge tube installed.
IPMC 605 Will need to install permanent electric box for
washer. Extension cord not allowed and washer
needs direct connection to outlet. 220 V dryer outlet
will need mounted to wall. Installation of new devices
will require permits and inspections.
Outlet in stairwell to upstairs is not grounded and will
need corrected.
IPMC 304.5 Foundation walls have large fractures in walls where
mortar is missing.Water is leaking into basement
from the foundation not being maintained.
Foundations shall be free from holes, breaks, and
loose or rotting materials.
IPMC 305 Living room ceiling is failing and potentially tiles will
fall into living room. Possible water leak in this area.
The interior of a structure shall be maintained in
good repair,structurally sound and in a sanitary
condition.
Fees
Initial Fees $
Initial Unit $
Additional Units $
Common Area $
Total Fee* $ 0.00
Does the property f No r Yes
require another
inspection?
Time 10:30
I I