HomeMy WebLinkAbout833 W 2nd St # 301-Rental Property Inspection-10/23/2018 Rental Property Inspection Report
City of Waterloo
715 Mulberry Street,
Waterloo, Iowa 50703
PH(319)-291-4319 Fax(319)-291-4262
Inspection Number 704
Inspector* Barry Stratton
Re-inspection Date 11/26/2018
Re-inspection# 2
File Upload
Property Info
Inspection Date* 10/23/2018
Unit Of
Street Address:* 833 W 2nd St#301
Tenant Name:
Phone Number:
Property Owner Info
Property Owner Name: Sheehan Property management LLC
Property Owner
Email
Property Owner 1809 Gibson St Cedar Falls, IA 50613
Address:
Property Owner Phone:
Inspection Items
Item Status
Address Posted r Pass r Cond r Fail
Siding r Pass r Cond r Fail
Roof r Pass r Cond r Fail
Item Status
Porches C Pass C Cond f Fail
Chimney C Pass C Cond (Fail
Basement C Pass C; Cond (Fail
Steps(outside) C Pass C Cond (Fail
Foundation C Pass C Cond (Fail
Hot Water Heater C Pass C Cond f•Fail
Heating System O Pass O Cond f•Fail
Electric a Pass C Cond f•Fail
Plumbing a Pass C Cond f•Fail
Egress C Pass C Cond f•Fail
Garbage C Pass C Cond (Fail
Dining Room C Pass C Cond (Fail
Livingroom O Pass C) Cond C Fail
Bedroom O Pass C Cond F Fail
Kitchen C Pass C Cond f•Fail
Batheroom C Pass C` Cond (Fail
Appliances C Pass C Cond f•Fail
Floors f Pass r) Cond f• Fail
Windows-Locks C Pass C Cond f•Fail
Door-Locks C Pass C Cond (Fail
Smoke Detectors C Pass r Cond f•Fail
Stairs(Inside) C Pass r Cond (Fail
Handrails C Pass r Cond f•Fail
Misc. Hazards-list C Pass C Cond f•Fail
Fire Extinguishers C Pass C Cond f•Fail
Common Area C Pass C Cond f•Fail
Attach Photos
Comments
Violation Comments
IFC 907 915 IPMC 704 Smoke detectors needed installed in unit to meet
code. CO detector is also needed installed.
Violation Comments
IPMC 602 Heating facilities not working in unit. Unit is being
heating with space heaters. Space heaters not
allowed.
IPMC 305 Peeling paint needs corrected. Mold present on
ceiling in living room needs mitigated. Find water
leak and repair. DO NOT just cover up with paint.
Bedroom ceiling and walls needs repaired from water
damage and abraded paint.
Tile around tub needs replaced. Missing tiles and
sharp edges.
IPMC 304.13 Every window shall be kept in sound condition, good
repair,and weather tight.
IPMC 605 Outlets need changer since a lot of them have been
damaged from sparking.
IPMC 603 Stove in unit not working and Mid-American has red
tagged stove. Change out stove for a stove that is in
working condition.
IFC 605.5 Extension cords in use for stove.Appliances need
direct connection.
IPMC 304.3 Premises Identification is needed on apartment door.
IPMC 108.1.3 Unit is unfit to occupy. Potential hazards exist and
are unsafe to occupants.
IPMC 102.5 Repairs, maintenance work,alterations shall be
executed and installed in a workmanlike manner and
installed in accordance with the code.
Common Areas
IPMC 304.13 Broken windows throughout building need repaired.
All broken glass needs repaired in doorways.All
units will need to meet occupancy standards.
IPMC 305 All holes will need repaired throughout building.
Peeling paint will need corrected throughout
building.
IFC 907 915 IPMC 704 Smoke detectors not working in common areas.
IFC 906 Update all fire extinguishers and replace missing fire
extinguishers.
IPMC 504 Water heaters shall be properly installed and
maintained in working order.Water heaters are
leaking and are missing discharge tubes. Contact
licensed contractor to replace water heaters.
Large leak in plumbing system in basement that will
need corrected by licensed contractor.
IPMC 605 Outlets in basement not grounded. Electric hazards
exist in basement from over a year ago that have
NOT been corrected yet.
IPMC 402.2 Lights in the egress path in common hallways and
stairways will need at least a 60 watt bulb installed to
light up top and bottom of stairs.
Violation Comments
IPMC 108.1.3 This building is unfit for human occupancy because
it is unsafe because of the hazards that exist.
Corrections need to be made in a timely manner or
the occupancy permits will be revoked.
IPMC 104.2 Inspections will occur in 30 days and failure to
comply fees will be assessed for non-compliance.
Outdated inspections exist in building that are over a
year old.
Bring building and all units up to the standards for
occupancy.
Fees
Initial Fees $
Initial Unit $
Additional Units $
Common Area $
Total Fee* $ 0.00
Does the property r No F Yes
require another
inspection?
Time 10:00