Loading...
HomeMy WebLinkAbout1134 Bertch Ave-Rental Property Inspection-1/31/2017Rental Property Inspection Report City of Waterloo 715 Mulberry Street, Waterloo, Iowa 50703 PH (319)-291-4319 Fax (319)-291-4262 Inspection Number 365 Inspector* Barry Stratton Re -inspection Date 3/2/2017 Re -inspection # 2 File Upload Property Info Inspection Date* 1/31/2017 Unit Of Street Address:* 1134 Bertch Ave Tenant Name: Phone Number: Property Owner Info Property Owner Name: Junker Rentals LLC Property Owner Email Property Owner Address: Property Owner Phone: Inspection Items Po Box 538 Waterloo, IA 50704 Item Status Address Posted r Pass r Cond C Fail Siding f Pass f Cond C Fail Roof (Pass f Cond C Fail Item Status Porches 0 Pass CS Cond f Fail Chimney C Pass 0 Cond C Fail Basement 0 Pass C' Cond 6* Fail Steps(outside) 0 Pass 0 Cond 6* Fail Foundation 0 Pass 0 Cond 6* Fail Hot Water Heater 0 Pass 0 Cond 6* Fail Heating System 0 Pass 0 Cond C Fail Electric 0 Pass 0 Cond 6* Fail Plumbing 0 Pass 0 Cond 6* Fail Egress 0 Pass 0 Cond C Fail Garbage 0 Pass 0 Cond C Fail Dining Room 0 Pass 0 Cond C Fail Livingroom 0 Pass 0 Cond 0 Fail Bedroom 0 Pass 0 Cond 0 Fail Kitchen 0 Pass 0 Cond C Fail Bathe room 0 Pass 0 Cond C Fail Appliances 0 Pass 0 Cond C Fail Floors 0 Pass 0 Cond CFail Windows -Locks 0 Pass 0 Cond 0 Fail Door -Locks 0 Pass 0 Cond C Fail Smoke Detectors 0 Pass 0 Cond 6* Fail Stairs(Inside) 0 Pass 0 Cond 6* Fail Handrails 0 Pass 0 Cond 6* Fail Misc. Hazards -list 0 Pass 0 Cond 6* Fail Fire Extinguishers 0 Pass 0 Cond 6* Fail Common Area 0 Pass 0 Cond C Fail Attach Photos Comments Violation Comments IFC 907 915IPMC 704 Need Smoke detectors and CO detectors installed to code. Need smoke detector in attic. IFC 906 Fire extinguisher needed in unit. Violation Comments IPMC 304.10 304.12 Handrails on front, back porch, and basement. Also handrails to upstairs. Need to replace front steps need landing at top of egress door. 3' landing needed at top and bottom from door and stairs need to meet code. IPMC 605 Need NM connector or slug to cover hole in electricial panel. 220V outlet for dryer need to be installed to code. Secure box to wall and 10/3 set in conduit. Electricial wire at base of basement stairs coming through floor and plug needs removed. Covers needed on switches and outlets. IPMC 504 Water heater leaking and missing covers. IPMC 305.4 Basement stairs not maintained in good repair and structurally sound. IPMC 304.5 Foundation leaking and water running into basement. Walls shall be maintained plumb, free from cracks & breaks, and in such condition to prevent the entry of debris and rodents. IRC 312 Window fall protection needed in bedrooms. In stairway window needs to be tempered. IPMC 305 Need transition strips in areas of the structure. IPMC 309 Bats present in basement. Remove batting and styrofoam from walls and eliminate infestation and bats. Fees Initial Fees $ Initial Unit $ Additional Units $ Common Area $ Total Fee* $ 0 Does the property C No ( Yes require another inspection? Time TBA