HomeMy WebLinkAbout425 Western Ave # 1-Rental Property Inspection-7_24_2017 Rental Property Inspection Report City of Waterloo 715 Mulberry Street, Waterloo, Iowa 50703 PH(319)-291-4319 Fax(319)-291-4262 Inspection Number 485 Inspector* Barry Stratton Re-inspection Date 8/24/2017 Re-inspection# 2 File Upload Property Info Inspection Date* 7/24/2017 Unit Of Street Address:* 425 Western Ave# 1 Tenant Name: Phone Number: Property Owner Info Property Owner Name: Tony Rentals LLC Property Owner tony.fischels@gmail.com Email Property Owner Po Box 567 Gilbertville, IA 50634 Address: Property Owner Phone: 319-415-8870 Inspection Items Item Status Address Posted r Pass r Cond r Fail Siding f Pass f Cond r Fail Roof (Pass f Cond r Fail Item Status Porches C Pass C Cond f Fail Chimney C Pass C Cond (Fail Basement C Pass C; Cond (Fail Steps(outside) C Pass C Cond (Fail Foundation C Pass C Cond (Fail Hot Water Heater C Pass C Cond (Fail Heating System O Pass O Cond (Fail Electric a Pass C Cond (Fail Plumbing a Pass C Cond (Fail Egress C Pass C Cond (Fail Garbage C Pass C Cond (Fail Dining Room C Pass C Cond (Fail Livingroom O Pass C) Cond C Fail Bedroom O Pass C Cond C Fail Kitchen C Pass C Cond (Fail Batheroom C Pass C` Cond f•Fail Appliances C Pass C Cond (Fail Floors f Pass r) Cond (Fail Windows-Locks C Pass C Cond C Fail Door-Locks C Pass C Cond (Fail Smoke Detectors C Pass r Cond f•Fail Stairs(Inside) C Pass r Cond (Fail Handrails C Pass r Cond (Fail Misc. Hazards-list C Pass C Cond F Fail Fire Extinguishers C Pass C Cond f•Fail Common Area C Pass C Cond f•Fail Attach Photos Comments .................. .......................................... Violation Comments IFC 907 915 IPMC 704 Smoke detectors needed in each bedroom, 1 outside bedrooms and a CO detector is needed in vicinity of the bedroom. Violation Comments IPMC 309 Roaches and mice in the unit and building. Need all infestation in building exterminated. IPMC 305 Under sink cabinet is not maintained in good repair. Hole that is currently there is possibly letting in rodents. Repair sink cabinet. IPMC 403.2 Exhaust fan in bathroom does not work. Replace exhaust fan in bathroom. Common Areas IFC 1010 Fire door on both levels need to close and latch. Doors are being held open and the upper door closure is not working.These are fire separation doors and needs to function as installed. IPMC 403.5 Dryer exhaust has come loose in laundry room Dryer is exhausting into laundry room. Pipe will need to be attached to exhaust vent with tape. IFC 907 Smoke detectors missing on mail level by west entrance. Ensure all smoke detectors are in working condition. IFC 906 Fire extinguisher is missing from main level. IPMC 304.13 Window on west side of building has bullet hole.All windows need to be maintained in sound condition and in good repair. IFC 915 Install CO detectors in all units in the vicinity of the bedrooms that need installed. Gas boiler on site by unit# 1. Fees Initial Fees $ Initial Unit $ Additional Units $ Common Area $ Total Fee* $ 0.00 Does the property r No F Yes require another inspection? Time 10:30