Loading...
HomeMy WebLinkAbout1113 1/2 Leavitt St-Rental Property Inspection-11/1/2017Rental Property Inspection Report City of Waterloo 715 Mulberry Street, Waterloo, Iowa 50703 PH (319)-291-4319 Fax (319)-291-4262 Inspection Number 544 Inspector* Barry Stratton Re -inspection Date 12/1/2017 Re -inspection # 2 File Upload Property Info Inspection Date* 11/1/2017 Unit Of Street Address:* 1113 1/2 Leavitt St Tenant Name: Phone Number: Property Owner Info Property Owner Name: Scott Salvas Property Owner Email Property Owner Address: Property Owner Phone: Inspection Items 1600 Forest Ave Waterloo, IA 50702 Item Status Address Posted C Pass C Cond C Fail Siding C Pass C Cond C Fail Roof C Pass C Cond C Fail Item Status Porches f Pass f Cond C Fail Chimney r Pass r Cond C Fail Basement r Pass r Cond F Fail Steps(outside) (Pass l Cond F Fail Foundation (Pass l Cond C Fail Hot Water Heater (Pass l Cond F Fail Heating System r Pass r Cond C Fail Electric (Pass l Cond F Fail Plumbing r Pass r Cond F Fail Egress (Pass l Cond F Fail Garbage r Pass r Cond F Fail Dining Room C Pass C Cond C Fail Livingroom C Pass r Cond C Fail Bedroom C Pass C Cond C Fail Kitchen (Pass l Cond C Fail Bathe room C Pass C Cond C Fail Appliances (Pass l Cond F Fail Floors (Pass l Cond F Fail Windows-Locks (Pass l Cond F Fail Door-Locks (Pass l Cond F Fail Smoke Detectors C Pass C Cond F Fail Stairs(Inside) (Pass l Cond C Fail Handrails (Pass l Cond F Fail Misc. Hazards-list C Pass C Cond F Fail Fire Extinguishers (Pass l Cond C Fail Common Area C Pass C Cond C Fail Attach Photos Comments Violation Comments IFC 907 915 IPMC 704 Smoke detectors needed in each bedroom and outside of the bedrooms. CO detector needed in basement. Violation Comments IPMC 304.10 Front stairs to unit are not to code and are unsafe. Handrail not attached to stairs. IPMC 504 Water heater leaking back through PT valve Have licensed contractor repair water heater. . Upstairs sink not draining correctly. Have licensed plumber make required corrections. IPMC 603 Need HVAC contractor inspect to ensure furnaces are in working condition. Change filters on all furnaces. Stove in not functional and needs replaced. Gas smell coming from stove. All vent registers need to be installed in place where needed. IPMC 309 Remove all garbage and debris from basement. IPMC 305 Basement walls have mold on walls that needs mitigated. Remove mold through out house and basement. Mold needs mitigated throughout the house and basement. All walls need to have pooling paint corrected. IPMC 605 Electric wires hanging throughout the house. All light need globes. IPMC 304.13 Replace all broken windows and broken glass in doors throughout the house. Window in stairwell exposed broken glass that need replaced. IPMC 702 Egress door from upstairs bedroom needs to be accessible and needs to be functional. IPMC 305.6 IPMC 305.4 All interior doors need to be in working condition and in place where needed. All doors that are broken need replaced. All floors need to be in good condition. Bathroom floor needs replaced and transition strips installed where needed. IPMC 108.1.3 House is unfit to occupy in its current condition. 9-7-4 9-7-5 Landlord license and rental registration needed for 2 units. Fees Initial Fees Initial Unit Additional Units Common Area Total Fee* $ 100.00 $ 100.00 Does the property C No d Yes require another inspection? Time 11:00