Loading...
HomeMy WebLinkAbout3350 University Ave-Rental Property Inspection-10_24_2017 Rental Property Inspection Report City of Waterloo 715 Mulberry Street, Waterloo, Iowa 50703 PH(319)-291-4319 Fax(319)-291-4262 Inspection Number 540 Inspector* Barry Stratton Re-inspection Date 12/14/2017 Re-inspection# 6 File Upload Property Info Inspection Date* 10/24/2017 Unit Of Street Address:* 3350 University Ave Tenant Name: Phone Number: Property Owner Info Property Owner Name: 3350 University Residential COOP Property Owner jack.ogdenii@gmail.com Email Property Owner 3538 Augusta Cr Waterloo, IA 50701 Address: Property Owner Phone: 319-830-5807 Inspection Items Item Status Address Posted r Pass r Cond r Fail Siding f Pass f Cond r Fail Roof (Pass f Cond r Fail Item Status Porches f Pass f Cond r Fail Chimney r Pass r Cond r Fail Basement r Pass r Cond r Fail Steps(outside) (Pass f Cond r Fail Foundation (Pass f Cond r Fail Hot Water Heater (Pass f Cond r Fail Heating System r Pass r Cond r Fail Electric (Pass f Cond F Fail Plumbing r Pass r Cond F Fail Egress (Pass f Cond F Fail Garbage r Pass r Cond r Fail Dining Room r Pass r Cond r Fail Livingroom r Pass r Cond r Fail Bedroom r Pass r Cond r Fail Kitchen (Pass f Cond r Fail Batheroom r Pass r Cond F Fail Appliances (Pass f Cond r Fail Floors (Pass f Cond F Fail Windows-Locks (Pass f Cond r Fail Door-Locks (Pass f Cond F Fail Smoke Detectors r Pass r Cond F Fail Stairs(Inside) (Pass f Cond r Fail Handrails (Pass f Cond r Fail Misc. Hazards-list r Pass r Cond F Fail Fire Extinguishers (Pass f Cond r Fail Common Area r Pass r Cond r Fail Attach Photos Comments Violation Comments IFC 907 915 IPMC 704 All smoke detectors will need to be in working condition. Some tenant rooms are missing some detectors. Violation Comments IFC 901.8 Smoke alarm pull station by North entrance has been tampered with and will need repaired. IBC 703 All holes in walls need to be covered by an approved process. Currently the way holes are covered doe not meet the fire separation of the fire code. Also rooms under construction will need to meet fire separation. IBC 105 All remodeling being done requires permits. Construction documents/plans will need to be submitted for reviewto ensure the scope of the work needs code. NFPA 25&72 In receipt of Primary Systems testing report.WIII need corrections and deficiencies corrected. IFC 1013 All e)at signs need to be in working condition.2nd Floor sign is damaged and needs replaced. IFC 1006 Interior fire doors will need hooked up to electronic closure system. Magnets currently in place to hold doors open are not operational. IPMC 403..5 Have all dryer vents cleaned and hooked back up to dryers. IFC 1010.1.9.1 North egress door is missing door closure and will need a new closure installed on dor. IPMC 504 Repair several water leaks throughout the building. IPMC 305.3 Replace all missing ceiling tiles throughout building. Repair all defective surface conditions in building. IFC All common areas and tenant/vacant rooms will need to meet the fire separation of the code. IFC 110.2 The Fire Marshal or the Fire Inspector of designee shall be authorized to immediate evacuation of the building deemed unsafe where such building is unsafe has hazardous conditions or unsafe equipment. IFC 110.4 Abatement is the responsibility of the owner of agent and it shall abate all unsafe conditions in building. Fees Initial Fees $ Initial Unit $ Additional Units $ Common Area $ Total Fee* $ 0.00 Does the property r No F Yes require another inspection? Time TBA