HomeMy WebLinkAbout1316 Baltimore St-Rental Property Inspection-9_8_2017Rental Property Inspection Report City of Waterloo 715 Mulberry Street, Waterloo, Iowa 50703 PH (319)-291-4319 Fax (319)-291-4262 Inspection Number 512 Inspector* Barry Stratton Re -inspection Date 10/9/2017 Re -inspection # 2 File Upload Property Info Inspection Date* 9/8/2017 Unit Of Street Address:* 1316 Baltimore St Tenant Name: Phone Number: Property Owner Info Property Owner Name: LDN Properties LLC Property Owner Email Property Owner Address: Po Box 2094 Waterloo, IA 50704 Property Owner Phone: 319-429-6195 Inspection Items Item Status Address Posted r Pass r Cond C Fail Siding f Pass f Cond C Fail Roof (Pass f Cond F Fail Item Status Porches f Pass f Cond ( Fail Chimney r Pass r Cond C Fail Basement r Pass r Cond F Fail Steps(outside) (Pass f Cond C Fail Foundation (Pass f Cond C Fail Hot Water Heater (Pass f Cond F Fail Heating System r Pass r Cond C Fail Electric (Pass f Cond F Fail Plumbing r Pass r Cond F Fail Egress (Pass f Cond F Fail Garbage r Pass r Cond C Fail Dining Room C Pass C Cond C Fail Livingroom C Pass r Cond C Fail Bedroom C Pass C Cond F Fail Kitchen (Pass f Cond C Fail Bathe room C Pass C Cond C Fail Appliances (Pass f Cond C Fail Floors (Pass f Cond F Fail Windows-Locks (Pass f Cond F Fail Door-Locks (Pass f Cond F Fail Smoke Detectors C Pass C Cond F Fail Stairs(Inside) (Pass f Cond F Fail Handrails (Pass f Cond C Fail Misc. Hazards-list C Pass C Cond F Fail Fire Extinguishers (Pass f Cond C Fail Common Area C Pass C Cond C Fail Attach Photos Comments Violation Comments IFC 907 915 IPMC 704 Smoke detectors needed in each bedroom and outside of the bedrooms. Smoke detector needed on each level and in basement. CO detector needed in vicinity of bedrooms. Violation Comments IPMC 605 Several electrical issues with all ceiling fans and lights they need replaced. All outlets and switches need covers. All outlets need to be in working condition throughout. Electric fixture in basement on ceiling not secured to box. Back room off kitchen light needs repaired. Electric panel is not grounded to water service. Need grounding strap on water neater. Check all electric fixtures to ensure meet code. All ceiling fan lights throughout need replaced. One outlet in orange bedroom hanging off wall. Replace light fixture in bathroom. Porch light not working. IPMC 305 Ceiling in kitchen needs replaced where water damage has occurred. All surfaces shall be maintained in good, clean, and sanitary condition. Kitchen cabinets need repaired since drawer fronts are missing. Replace all carpet that has tears and damage that may cause trip hazards. IPMC 603 Refrigerator is leaking onto floor. Washing machine in basement is missing front cover. IPMC 304.10 Stairs to basement are unsafe with the stair treads very unstable. Replace unsafe treads. Outside deck needs new balusters installed since several are broken. Replace posts that are loose or broken. IPMC 504 Basement drain backing up. Have Plumber check drain to ensure no blockage. Food on basement from kitchen sink on basement floor coming up through floor drain. Water heater is missing front panel on water heater. IPMC 307 IBC 1015 IFC 605.5 IPMC 304.13 IPMC 304.7 IPMC 702 Fees Initial Fees Handrails to upstairs need to be in place. Also need handrails on front porch stairs. Window in stairway needs to be tempered glass and have limiters installed for fall prevention. Remove all extension cords in house. Broken window and screen in bathroom needs replaced. House will need a new roof installed. Shingles are in sound condition and good repair. Side entrance door blocked going to basement. Egress shall not be blocked and door shall be in working condition. Initial Unit $ Additional Units $ Common Area $ Total Fee* $ 0.00 Does the property r No F Yes require another inspection? Time 1:00