HomeMy WebLinkAbout3350 University Ave-Rental Property Inspection-9_13_2017 Rental Property Inspection Report City of Waterloo 715 Mulberry Street, Waterloo, Iowa 50703 PH(319)-291-4319 Fax(319)-291-4262 Inspection Number 517 Inspector* Barry Stratton Re-inspection Date 10/24/2017 Re-inspection# File Upload Property Info Inspection Date* 9/13/2017 Unit Of Street Address:* 3350 University Ave Tenant Name: Phone Number: Property Owner Info Property Owner Name: 3350 University Residential COOP Property Owner jack.ogdenii@gmail.com Email Property Owner 3538 Augusta Cr Waterloo, IA 50701 Address: Property Owner Phone: 319-830-5807 Inspection Items Item Status Address Posted r Pass r Cond r Fail Siding f Pass f Cond r Fail Roof (Pass f Cond r Fail Item Status Porches C Pass C Cond f Fail Chimney C Pass C Cond (Fail Basement C Pass C; Cond (Fail Steps(outside) C Pass C Cond (Fail Foundation C Pass C Cond (Fail Hot Water Heater C Pass C Cond (Fail Heating System O Pass O Cond (Fail Electric a Pass C Cond (Fail Plumbing a Pass C Cond (Fail Egress C Pass C Cond (Fail Garbage C Pass C Cond (Fail Dining Room C Pass C Cond (Fail Livingroom O Pass C) Cond C Fail Bedroom O Pass C Cond C Fail Kitchen C Pass C Cond (Fail Batheroom C Pass C` Cond f•Fail Appliances C Pass C Cond (Fail Floors f Pass r) Cond (Fail Windows-Locks C Pass C Cond C Fail Door-Locks C Pass C Cond f•Fail Smoke Detectors C Pass r Cond f•Fail Stairs(Inside) C Pass r Cond (Fail Handrails C Pass r Cond (Fail Misc. Hazards-list C Pass C Cond F Fail Fire Extinguishers C Pass C Cond (Fail Common Area C Pass C Cond f•Fail Attach Photos Comments Violation Comments IFC 907 915 IPMC 704 All smoke detectors need to be in working condition.Detectors to include tenant rooms and common areas. Violation Comments IFC 901.8 Fire alarm pull station has been tampered with and will need replaced on the 1 st floor by the rear entrance door. IBC 703 All holes in walls need to be covered by any such material to meet the codes fire separation requirements.Access panels with a fire rating to meet code or drywall installed such as 5/8 type X gypsum to meet the fire separation requirement throughout the building. Rooms under construction will need to also meet the fire separation of the fire and building code. The current application does not meet the fire and building code. IBC 105 All remodeling being done will require permits for work. Construction documents/plan will need to be submitted for review to ensure the scope of work will meet code. Commercial Fire Inspection On October 24th starting at approx 9:00 a fire inspection will be done on all rooms,common areas, and all other areas required by the code. NFPA 25 NFPA 72 Sprinkler and Alarm testing reports will be required at time of inspection. Fees Initial Fees $ Initial Unit $ Additional Units $ Common Area $ Total Fee* $ 0.00 Does the property r No F Yes require another inspection? Time 9:00