HomeMy WebLinkAbout1013 Mulberry St_06182020WATERLOO FIRE RESCUE INSPECTION REPORT 1013 MULBERRY ST, WATERLOO IA 50703 DETAILS Inspection Date: 06/18/2020 | Inspection Type: Rental Inspection | Inspection Number: 4458 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1031.7 - Emergency escape and rescue openings Required emergency escape and rescue openings shall be maintained in accordance with the code in effect at the time of construction, and the following: Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles, grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector: BARRY STRATTON - Comments: NO egress window in basement. Basement being used as a bedroom. Cease using basement for sleeping purposes. FAIL 605.1 - Abatement of electrical hazards Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON - Comments: Outlets in units not working. All outlets shall be in working condition. Electric panel in basement has open slot in panel with exposed wires. Electric outlet in basement has exposed wires. Hanging light light in unit # 4 has wire nuts on cord and this is unsafe and needs removed. Hire licensed electrician to make electrical repairs. Bath fan in unit # 4 will need replaced and exhaust to the exterior of the house. All lights in hallways shall illuminate so visibility can been seen going up/down stairs. FAIL 906.1 - Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B: C. 2. Within 30 feet (9144 mm) of commercial cooking equipment. 3. In areas where flammable or combustible liquids are stored, used or dispensed. 4. On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1. 6. Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON - Comments: Fire extinguishers will need to be installed to meet code and all extinguishers will need updated. Printed on 07/24/2020 @ 16:00 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 907.2.11 - Single- and multiple-station smoke alarms Listed single- and multiple- station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY STRATTON - Comments: Smoke detectors will need to be in working condition in all units/building. CO detectors will need installed to code in all units. FAIL 915.4 - Carbon monoxide alarms Carbon monoxide alarms shall comply with Sections 915.4.1 through 915.4.3. Inspector: BARRY STRATTON - Comments: CO detectors will need installed to meet code. FAIL R1 - Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either the public or occupants of the structure? (IPMC 108.1.1) Inspector: BARRY STRATTON - Comments: Mold potential to form with all the leaks in building. FAIL R2 - Unsafe Equipment Was the presence of unsafe equipment noted during the inspection? Equipment may include boilers, heating equipment, elevator, moving stairways, electrical wiring, and flammable liquid containers. (IPMC 108.1.2) Inspector: BARRY STRATTON - Comments: Open electric hazards in building and outlets not working. Wiring exposed in panels and open boxes in basement. All hook latch/locks will need to be removed. FAIL R4 - Exterior Property Areas Is the exterior property area maintained in a clean, safe, and sanitary condition? This includes grading and drainage, sidewalks and driveways, weeds, and pest infestations. (IPMC 302) Inspector: BARRY STRATTON - Comments: Roof and gutters will need repaired. Roof water leaking into attic . Guard rail around front porch is not in good condition and is missing balusters. FAIL R5 - Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state? (IPMC 304) Inspector: BARRY STRATTON - Comments: Roof & Gutters FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Printed on 07/24/2020 @ 16:00 Page 2 of 4 STATUS CODE DESCRIPTION Inspector: BARRY STRATTON - Comments: Ceiling in unit # 4 is water damaged. All areas that are damaged will need removed and replaced. All latch locks will need removed throughout. All door hardware on all doors will need to be in working condition that will allow door to close and latch. Handrails will need to be secured to wall going upstairs. Handrail to basement is not proper size. Windows and screens will need repaired/replaced. Windows will need to be capable of opening and closing. Kitchen cabinets in units will need repaired. Drums and containers in attic that are catching water from roof leaking will need removed. All kitchen cabinets in all units will need to be clean, capable of being used to prepare meals. All drawers will need to work and all drawers missing will need replaced. All floors in units will be maintained in a clean, safe, and sanitary condition. FAIL R6.A. - Interior Structure- Unsafe Conditions Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Inspector: BARRY STRATTON - Comments: Electric hazards, floors, ceilings, handrails, condition of the units, basement being used as bedroom without egress windows. FAIL R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) Inspector: BARRY STRATTON - Comments: Plumbing leaks in unit # 4 bathroom pipe running up wall by toilet. Stove and refrigerator will need replaced in unit # 4. Check all appliances in all units. Unit # 1 stove not working and is unsafe in current condition. Plumbing leaking in basement. Toilet not working in unit # 1. FAIL R6.D. - Receptacles Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding-type receptacle or a receptacle with a GFCI. Every bathroom shall contain not less than one receptacle. Any new bathroom receptacle shall have GFCI protection. All receptacles shall have the appropriate faceplate cover. (IPMC 605.2) Inspector: BARRY STRATTON - Comments: All outlets will need attention and capable of being in working condition. GENERAL NOTES BARRY STRATTON - 06/18/2020 @ 11:55 1013 Mulberry St Units 1, 2, 3, & 4 will need to be repaired so they will meet rental code. REINSPECTION DATE 07/21/2020 Printed on 07/24/2020 @ 16:00 Page 3 of 4 CONTACT SIGNATURE Mike & Gloria Jones Signed on: 06/18/2020 @ 12:02 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 06/18/2020 @ 12:02 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 16:00 Page 4 of 4