Loading...
HomeMy WebLinkAbout112 Argyle St_111319WATERLOO FIRE RESCUE INSPECTION REPORT 112 ARGYLE ST, WATERLOO IA 50703 DETAILS Inspection Date: 11/13/2019 | Inspection Type: Rental Inspection | Inspection Number: 3732 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A | Fee: $50.00 STATUS CODE DESCRIPTION FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON - Comments: All doors need to be weather tight and capable of preforming their intended function. FAIL 1031.7 - Emergency escape and rescue openings Required emergency escape and rescue openings shall be maintained in accordance with the code in effect at the time of construction, and the following: Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles, grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector: BARRY STRATTON - Comments: Basement hatchway needs repaired and security to building through this area needs repaired. FAIL 505.1 - Address identification New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) high with a minimum stroke width of 1/2 (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspector: BARRY STRATTON - Comments: Need address posted on both apartments. Printed on 07/24/2020 @ 14:49 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 605.1 - Abatement of electrical hazards Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON - Comments: Romex hanging on gas line in basement. Globes needed on lights. GFCI in bathroom and kitchen not working. Extension cords and multiple adapters are not allowed. FAIL 907.2.11 - Single- and multiple-station smoke alarms Listed single- and multiple- station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY STRATTON - Comments: Smoke detectors needed in each bedroom and outside of the bedrooms. Smoke detector needed in basement to be in working condition. FAIL R1 - Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either the public or occupants of the structure? (IPMC 108.1.1) Inspector: BARRY STRATTON - Comments: Stair treads to the upstairs not capable of supporting imposed loads. FAIL R2 - Unsafe Equipment Was the presence of unsafe equipment noted during the inspection? Equipment may include boilers, heating equipment, elevator, moving stairways, electrical wiring, and flammable liquid containers. (IPMC 108.1.2) Inspector: BARRY STRATTON - Comments: Furnace FAIL R5 - Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state? (IPMC 304) Inspector: BARRY STRATTON - Comments: Need landings at egress doors. Install landings @ doors. FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Inspector: BARRY STRATTON - Comments: Floors, doors, transition strips, bathtub faucet needs replaced. Vise grips in place to turn on shower. Walls in basement in place holding up supporting upper levels of house not engineered for that application. Wood not treated for concrete application and floor supports not engineered. All interior doors and holes in walls need repaired. Transition strips needed installed where floor transitions from room to room. Handrails need repaired and installed to code to the basement and upstairs. Printed on 07/24/2020 @ 14:49 Page 2 of 4 STATUS CODE DESCRIPTION FAIL R6.A. - Interior Structure- Unsafe Conditions Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Inspector: BARRY STRATTON - Comments: Floor supports not capable of supporting imposed loads. FAIL R6.B. - Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F? (IPMC 602.2) Inspector: BARRY STRATTON - Comments: Furnace flue has hole in exhaust flue. Needs replaced ASAP. FAIL R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) Inspector: BARRY STRATTON - Comments: Water heater not capable of maintaining 110 degrees. Dryer is not exhausting to the exterior. Water supply lines draped over floor joists. Lines needs installed to meet code. FAIL R6.D. - Receptacles Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding-type receptacle or a receptacle with a GFCI. Every bathroom shall contain not less than one receptacle. Any new bathroom receptacle shall have GFCI protection. All receptacles shall have the appropriate faceplate cover. (IPMC 605.2) Inspector: BARRY STRATTON - Comments: GENERAL NOTES BARRY STRATTON - 11/13/2019 @ 15:06 Roof leaking. Water damaged ceiling inside unit. IPMC 304.7 BARRY STRATTON - 11/13/2019 @ 15:07 Windows need fall protection devices on windows. IBC 716 BARRY STRATTON - 11/13/2019 @ 15:09 Plaster falling off walls in basement. Fix all holes in walls. Reair all peeling paint. IPMC 305 BARRY STRATTON - 11/13/2019 @ 15:09 Cockroach infestation and bug infestation. IPMC 309 BARRY STRATTON - 11/13/2019 @ 15:12 9-7-4 9-7-5 Failure to register. Citation shall be issued for failure to register. Printed on 07/24/2020 @ 14:49 Page 3 of 4 REINSPECTION DATE 12/11/2019 CONTACT SIGNATURE A to Z Rentals LLC Signed on: 11/13/2019 @ 15:11 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 11/13/2019 @ 15:10 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 14:49 Page 4 of 4