HomeMy WebLinkAbout1220 Meadow Ln_03302020WATERLOO FIRE RESCUE INSPECTION REPORT 1220 MEADOW LN, WATERLOO IA 50701 DETAILS Inspection Date: 03/30/2020 | Inspection Type: Rental Inspection | Inspection Number: 3912 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A | Fee: $50.00 STATUS CODE DESCRIPTION FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON - Comments: Interior fire doors shall remain shut at all times. FAIL 506.1 - Where required Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes, the fire code official is authorized to require a key box to be installed in an approved location. The key box shall be of an approved type listed in accordance with UL 1037, and shall contain keys to gain necessary access as required by the fire code official. Inspector: BARRY STRATTON - Comments: Wrong knox box installed on building. 3200 Series is needed on building. FAIL 901.6 - Inspection, testing and maintenance Fire detection, alarm, and extinguishing systems, mechanical smoke exhaust systems, and smoke and heat vents shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. Inspector: BARRY STRATTON - Comments: Audible alarm in building needs tested. FAIL 901.6.1 - Standards Fire protection systems shall be inspected, tested and maintained in accordance with the referenced standards listed in Table . Inspector: BARRY STRATTON - Comments: FAIL 907.2.11 - Single- and multiple-station smoke alarms Listed single- and multiple- station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY STRATTON - Comments: Smoke detectors on each level are not working. Printed on 07/24/2020 @ 15:49 Page 1 of 2 STATUS CODE DESCRIPTION FAIL 915.4 - Carbon monoxide alarms Carbon monoxide alarms shall comply with Sections 915.4.1 through 915.4.3. Inspector: BARRY STRATTON - Comments: CO detectors needed installed to code. FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Inspector: BARRY STRATTON - Comments: Holes in walls need corrected. Dryer vent needs cleaned behind dryer. FAIL R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) Inspector: BARRY STRATTON - Comments: Dryer vent needs cleaned. REINSPECTION DATE 04/27/2020 CONTACT SIGNATURE 30 Something Real Estate Signed on: 03/30/2020 @ 11:04 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 03/30/2020 @ 11:04 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 15:49 Page 2 of 2