HomeMy WebLinkAbout1220 Meadow Ln_03302020WATERLOO FIRE RESCUE
INSPECTION REPORT
1220 MEADOW LN, WATERLOO IA 50701
DETAILS
Inspection Date: 03/30/2020 | Inspection Type: Rental Inspection | Inspection Number: 3912 | Shift: N/A | Station: N/A |
Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A | Fee: $50.00
STATUS CODE DESCRIPTION
FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON - Comments: Interior fire doors shall remain shut at all
times.
FAIL 506.1 - Where required Where access to or within a structure or an area is restricted because of secured
openings or where immediate access is necessary for life-saving or fire-fighting
purposes, the fire code official is authorized to require a key box to be installed in an
approved location. The key box shall be of an approved type listed in accordance with
UL 1037, and shall contain keys to gain necessary access as required by the fire code
official.
Inspector: BARRY STRATTON - Comments: Wrong knox box installed on building. 3200
Series is needed on building.
FAIL 901.6 - Inspection, testing and
maintenance
Fire detection, alarm, and extinguishing systems, mechanical smoke exhaust
systems, and smoke and heat vents shall be maintained in an operative condition at
all times, and shall be replaced or repaired where defective. Nonrequired fire
protection systems and equipment shall be inspected, tested and maintained or
removed.
Inspector: BARRY STRATTON - Comments: Audible alarm in building needs tested.
FAIL 901.6.1 - Standards Fire protection systems shall be inspected, tested and maintained in accordance with
the referenced standards listed in Table .
Inspector: BARRY STRATTON - Comments:
FAIL 907.2.11 - Single- and
multiple-station smoke
alarms
Listed single- and multiple- station smoke alarms complying with UL 217 shall be
installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
Inspector: BARRY STRATTON - Comments: Smoke detectors on each level are not
working.
Printed on 07/24/2020 @ 15:49
Page 1 of 2
STATUS CODE DESCRIPTION
FAIL 915.4 - Carbon monoxide
alarms
Carbon monoxide alarms shall comply with Sections 915.4.1 through 915.4.3.
Inspector: BARRY STRATTON - Comments: CO detectors needed installed to code.
FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair, structurally sound, and in a sanitary condition? (IPMC 305)
Inspector: BARRY STRATTON - Comments: Holes in walls need corrected. Dryer vent
needs cleaned behind dryer.
FAIL R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition? (IPMC 603.1)
Inspector: BARRY STRATTON - Comments: Dryer vent needs cleaned.
REINSPECTION DATE
04/27/2020
CONTACT SIGNATURE
30 Something Real Estate
Signed on: 03/30/2020 @ 11:04
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on: 03/30/2020 @ 11:04