Loading...
HomeMy WebLinkAbout1267 Ravenwood Rd_01032020WATERLOO FIRE RESCUE INSPECTION REPORT 1267 RAVENWOOD RD, WATERLOO IA 50702 DETAILS Inspection Date: 01/03/2020 | Inspection Type: Rental Inspection | Inspection Number: 3818 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A | Fee: $50.00 STATUS CODE DESCRIPTION FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON - Comments: Interior Fire doors still being held open and will need closures adjusted so doors will close and latch. FAIL 1018.1 - General Aisles and aisle accessways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle accessways shall be provided from all occupied portions of the exit access that contain seats, tables, furnishings, displays and similar fixtures or equipment. The minimum width or required capacity of aisles shall be unobstructed. Exception: Encroachments complying with Section 1005.7. Inspector: BARRY STRATTON - Comments: FAIL 2108.4 - Portable fire extinguishers Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and Section 906. A minimum of two, 2-A: 10-B: C portable fire extinguishers shall be provided near the doors inside dry cleaning rooms containing Type II, Type III-A and Type III-B dry cleaning systems. Inspector: BARRY STRATTON - Comments: Fire extinguisher is now missing on 1st Floor FAIL 907.2.11 - Single- and multiple-station smoke alarms Listed single- and multiple- station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY STRATTON - Comments: Smoke detectors can still be heard throughout building beeping. Smoke detectors shall be maintained in operating condign. REINSPECTION DATE 02/03/2020 Printed on 07/24/2020 @ 15:11 Page 1 of 2 CONTACT SIGNATURE SVS Investments LLC Signed on: 01/03/2020 @ 11:05 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 01/03/2020 @ 11:05 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 15:11 Page 2 of 2