HomeMy WebLinkAbout1310 Stratford Ave_01272020WATERLOO FIRE RESCUE INSPECTION REPORT 1310 STRATFORD AVE, WATERLOO IA 50701 DETAILS Inspection Date: 01/27/2020 | Inspection Type: Rental Inspection | Inspection Number: 4026 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 605.1 - Abatement of electrical hazards Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON - Comments: 3 Prong Outlets in kitchen and living room are not grounded FAIL 906.1 - Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B: C. 2. Within 30 feet (9144 mm) of commercial cooking equipment. 3. In areas where flammable or combustible liquids are stored, used or dispensed. 4. On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1. 6. Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON - Comments: Need updated fire extinguisher in house. Current extinguisher is dated September 2016. FAIL 907.2.11 - Single- and multiple-station smoke alarms Listed single- and multiple- station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY STRATTON - Comments: Smoke detectors are needed in every bedroom and outside of the bedrooms. Smoke detectors shall be in operable condition. FAIL 915.4 - Carbon monoxide alarms Carbon monoxide alarms shall comply with Sections 915.4.1 through 915.4.3. Inspector: BARRY STRATTON - Comments: CO detector are required to be in vicinity of the bedrooms. Back bedroom shall require CO detector in the bedroom since there is a fuel fired appliance in bedroom. Printed on 07/24/2020 @ 15:21 Page 1 of 3 STATUS CODE DESCRIPTION FAIL R2 - Unsafe Equipment Was the presence of unsafe equipment noted during the inspection? Equipment may include boilers, heating equipment, elevator, moving stairways, electrical wiring, and flammable liquid containers. (IPMC 108.1.2) Inspector: BARRY STRATTON - Comments: Furnace FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Inspector: BARRY STRATTON - Comments: Carpet needs replaced. Carpet is worn and several trip hazards throughout house. FAIL R6.A. - Interior Structure- Unsafe Conditions Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Inspector: BARRY STRATTON - Comments: Electric and furnace FAIL R6.B. - Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F? (IPMC 602.2) Inspector: BARRY STRATTON - Comments: Furnace not functioning to code. Furnace continues to shut down. Furnace needs replaced. Obtain licensed contractor to do work & get permits/inspections. All duct work and vents shall be cleaned. All mechanical appliances shall be installed and maintained in a safe working condition and shall be capable of preforming their intended functions. FAIL R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) Inspector: BARRY STRATTON - Comments: Water heater installed in 2016 did not have permits and inspections. Exhaust fan in bathroom needs to be replaced. REINSPECTION DATE 02/27/2020 CONTACT SIGNATURE Eric Myszka & Nicole Boesen Signed on: 01/27/2020 @ 14:32 Printed on 07/24/2020 @ 15:21 Page 2 of 3 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 01/27/2020 @ 14:31 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 15:21 Page 3 of 3