Loading...
HomeMy WebLinkAbout1412 W 3rd St_01082020WATERLOO FIRE RESCUE INSPECTION REPORT 1412 W 3RD ST, WATERLOO IA 50701 DETAILS Inspection Date: 01/08/2020 | Inspection Type: Rental Inspection | Inspection Number: 3929 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1103.9 - Carbon monoxide alarms Existing Group I-1, I-2, I-4 and R occupancies shall be equipped with carbon monoxide alarms in accordance with Section 915, except that the carbon monoxide alarms shall be allowed to be solely battery operated. Inspector: BARRY STRATTON - Comments: FAIL 605.1 - Abatement of electrical hazards Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON - Comments: Electric panel missing cover. Outlets in kitchen have open neutrals. Electric outlet missing for stove. Globes are missing on light fixtures. Extension cords running to garage. FAIL 907.2.11 - Single- and multiple-station smoke alarms Listed single- and multiple- station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY STRATTON - Comments: Smoke detectors are needed in each bedroom and outside of the bedrooms, Smoke detectors needed in basement and on each level. FAIL 915.4 - Carbon monoxide alarms Carbon monoxide alarms shall comply with Sections 915.4.1 through 915.4.3. Inspector: BARRY STRATTON - Comments: CO detectors needed outside of any room used as a bedroom. FAIL R1 - Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either the public or occupants of the structure? (IPMC 108.1.1) Inspector: BARRY STRATTON - Comments: Windows, siding, trim on window, porch floor, doors, jambs, door hardware all need attention. Printed on 07/24/2020 @ 15:13 Page 1 of 3 STATUS CODE DESCRIPTION FAIL R2 - Unsafe Equipment Was the presence of unsafe equipment noted during the inspection? Equipment may include boilers, heating equipment, elevator, moving stairways, electrical wiring, and flammable liquid containers. (IPMC 108.1.2) Inspector: BARRY STRATTON - Comments: Electric panel, water heater, plumbing backup. FAIL R3 - Unfit for Human Occupancy Is the structure found to be fit for human occupancy according to the code? (IPMC 108.1.3) Inspector: BARRY STRATTON - Comments: Electric hazards, no hot water, egress paths blocked, doors off hinges, doors, door hardware & jambs not capable of performing their intended function. Have house inspected before moving another tenant. FAIL R5 - Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state? (IPMC 304) Inspector: BARRY STRATTON - Comments: Exterior siding, windows, window trim, flooring, doors. FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Inspector: BARRY STRATTON - Comments: Screen door needs replaced. Front deck needs new decking. Porch windows need replaced. Broken glass needs cleaned up and replaced. Stove not working. Kitchen faucet needs replaced. Egress paths blocked in several areas of house/porch. Kitchen ceiling needs replaced from bathroom upstairs leaking. Bathroom floor needs replaced from water damage. Remove all garbage and debris in house and basement. FAIL R6.A. - Interior Structure- Unsafe Conditions Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Inspector: BARRY STRATTON - Comments: Electric issues, no hot water, egress paths blocked, sewage in basement from drain backing up, water not working, light fixtures hanging from walls. FAIL R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) Inspector: BARRY STRATTON - Comments: Water heater installed without permits. Water heater not working because of water damage from drain backup. Kitchen faucet not working, stove not working. Cover missing on water heater. If water heater was damaged and water came into contact with gas valve water heater will need replaced. GENERAL NOTES Printed on 07/24/2020 @ 15:13 Page 2 of 3 BARRY STRATTON - 01/08/2020 @ 14:57 IRC 105 No permit for water heater. Citation shall be issued to contractor. BARRY STRATTON - 01/08/2020 @ 14:55 9-7-4 9-7-5 Landlord license and rental registration needed for 2020. REINSPECTION DATE 02/05/2020 CONTACT SIGNATURE Shirley Curran Signed on: 01/08/2020 @ 14:58 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 01/08/2020 @ 14:58 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 15:13 Page 3 of 3