Loading...
HomeMy WebLinkAbout1416 Washington Street_091219WATERLOO FIRE RESCUE INSPECTION REPORT 1416 WASHINGTON ST, WATERLOO IA 50702 DETAILS Inspection Date: 09/12/2019 | Inspection Type: Rental Inspection | Inspection Number: 3405 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1103.9 - Carbon monoxide alarms Existing Group I-1, I-2, I-4 and R occupancies shall be equipped with carbon monoxide alarms in accordance with Section 915, except that the carbon monoxide alarms shall be allowed to be solely battery operated. Inspector: BARRY STRATTON - Comments: CO detectors needed in vicinity of the bedrooms in Units # 102, # 301 FAIL 506.1 - Where required Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes, the fire code official is authorized to require a key box to be installed in an approved location. The key box shall be of an approved type listed in accordance with UL 1037, and shall contain keys to gain necessary access as required by the fire code official. Inspector: BARRY STRATTON - Comments: Knox boxes need installed per requirements of the Fire Marshal. Lt Chris Ferguson 319-493-1136 FAIL 703.1 - Maintenance The required fire-resistance rating of fire-resistance-rated construction, including, but not limited to, walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems, shall be maintained. Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged, altered, breached or penetrated. Records of inspections and repairs shall be maintained. Where concealed, such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel, access door, ceiling tile or similar movable entry to the space. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance-rated assemblies shall be protected by self- or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector: BARRY STRATTON - Comments: Egress doors on 2nd & 3rd Floors need work. Printed on 07/24/2020 @ 10:40 Page 1 of 2 STATUS CODE DESCRIPTION FAIL 907.2.11 - Single- and multiple-station smoke alarms Listed single- and multiple- station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY STRATTON - Comments: Smoke detectors shall be maintained and in working condition. FAIL 915.4 - Carbon monoxide alarms Carbon monoxide alarms shall comply with Sections 915.4.1 through 915.4.3. Inspector: BARRY STRATTON - Comments: FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Inspector: BARRY STRATTON - Comments: Kitchen walls, bathroom walls & ceiling, kitchen drawer fronts need maintenance in unit # 102. Floors shall be maintained in good condition. Bathroom wall and medicine cabinet need repaired in unit # 201 REINSPECTION DATE 10/10/2019 CONTACT SIGNATURE Christin Signed on: 09/12/2019 @ 10:47 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 09/12/2019 @ 10:47 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 10:40 Page 2 of 2