HomeMy WebLinkAbout1815 Lafayette St_01072020WATERLOO FIRE RESCUE INSPECTION REPORT 1815 LAFAYETTE ST, WATERLOO IA 50703 DETAILS Inspection Date: 01/07/2020 | Inspection Type: Rental Inspection | Inspection Number: 3925 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1031.2 - Reliability Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector: BARRY STRATTON - Comments: Wall needs repaired going to lower level # 3. FAIL 1031.7 - Emergency escape and rescue openings Required emergency escape and rescue openings shall be maintained in accordance with the code in effect at the time of construction, and the following: Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles, grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector: BARRY STRATTON - Comments: Egress window in bedroom does not meet code. Bed in living room being used for sleeping purposes. No egress window in living room. FAIL 1103.9 - Carbon monoxide alarms Existing Group I-1, I-2, I-4 and R occupancies shall be equipped with carbon monoxide alarms in accordance with Section 915, except that the carbon monoxide alarms shall be allowed to be solely battery operated. Inspector: BARRY STRATTON - Comments: FAIL 605.1 - Abatement of electrical hazards Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON - Comments: Electric outlets have tension issues that need addressed. Outlets need changed out. All light fixtures need approved globes installed. Open neutral on outlet in living room. Need knockouts installed on all open areas in electric panels. Printed on 07/24/2020 @ 15:13 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 906.3 - Size and distribution The size and distribution of portable fire extinguishers shall be in accordance with Sections .1 through .4. Inspector: BARRY STRATTON - Comments: Fire extinguisher needs replaced. FAIL 906.9 - Extinguisher installation The installation of portable fire extinguishers shall be in accordance with Sections 906.9.1 through 906.9.3. Inspector: BARRY STRATTON - Comments: FAIL 907.2.11 - Single- and multiple-station smoke alarms Listed single- and multiple- station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY STRATTON - Comments: Need smoke detectors in each bedroom and outside of the bedrooms. FAIL 915.4 - Carbon monoxide alarms Carbon monoxide alarms shall comply with Sections 915.4.1 through 915.4.3. Inspector: BARRY STRATTON - Comments: CO detectors needed in vicinity of the bedrooms. FAIL R1 - Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either the public or occupants of the structure? (IPMC 108.1.1) Inspector: BARRY STRATTON - Comments: Potential mold growth and bug infestation. FAIL R5 - Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state? (IPMC 304) Inspector: BARRY STRATTON - Comments: Need handrails to lower apartment # 3. FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Inspector: BARRY STRATTON - Comments: Entry door needs to be weather tight. Door hardware needs replaced. Holes in walls need repaired. Peeling paint needs corrected. Ceiling tiles need replaced in living room and bathroom. Carpet in living room has tears and needs replaced. Several trip hazards from condition of carpet. Need handrail installed on stairs to lower unit # 3. Printed on 07/24/2020 @ 15:13 Page 2 of 3 STATUS CODE DESCRIPTION FAIL R6.A. - Interior Structure- Unsafe Conditions Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Inspector: BARRY STRATTON - Comments: Open holes on electric panel. Egress window does not meet code. FAIL R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) Inspector: BARRY STRATTON - Comments: Toilet does not flush possible flushing valve needs replaced. Sink needs mounting to wall in bathroom. Sewer stack leaking in kitchen. REINSPECTION DATE 02/05/2020 CONTACT SIGNATURE Encanto Associates LLC Signed on: 01/07/2020 @ 11:23 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 01/07/2020 @ 11:23 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 15:13 Page 3 of 3