HomeMy WebLinkAbout2141 Logan Ave_06092020WATERLOO FIRE RESCUE
INSPECTION REPORT
2141 LOGAN AVE, WATERLOO IA 50703
DETAILS
Inspection Date: 06/09/2020 | Inspection Type: Rental Inspection | Inspection Number: 4419 | Shift: N/A | Station: N/A |
Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A | Fee: $50.00
STATUS CODE DESCRIPTION
FAIL 1031.2 - Reliability Required exit accesses, exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied. An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector: BARRY STRATTON - Comments: Hook locks being used on doors on porch
will need to be removed. Door are blocked because furniture moved from water
damage.
FAIL 605.1 - Abatement of
electrical hazards
Identified electrical hazards shall be abated. Identified hazardous electrical conditions
in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON - Comments: Water damage to electric wiring and
electric fixtures. Remove all water damaged product associated with electric system
that was damaged and replace. Obtain services of a licensed electrical contractor to
make electric system safe. Electric installed in new bathroom in basement does not
have current permits for installation. Grounding of electric system will need to be
verified.
FAIL 906.1 - Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A: 10-B: C. 2. Within 30 feet (9144 mm)
of commercial cooking equipment. 3. In areas where flammable or combustible
liquids are stored, used or dispensed. 4. On each floor of structures under
construction, except Group R-3 occupancies, in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1. 6. Special-hazard areas,
including but not limited to laboratories, computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARRY STRATTON - Comments: Need updated fire extinguisher in unit.
Printed on 07/24/2020 @ 15:56
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 907.2.11 - Single- and
multiple-station smoke
alarms
Listed single- and multiple- station smoke alarms complying with UL 217 shall be
installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
Inspector: BARRY STRATTON - Comments: Smoke detectors are needed in EACH
bedroom and outside of EACH bedroom.
FAIL R1 - Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either
the public or occupants of the structure? (IPMC 108.1.1)
Inspector: BARRY STRATTON - Comments:
FAIL R2 - Unsafe Equipment Was the presence of unsafe equipment noted during the inspection? Equipment may
include boilers, heating equipment, elevator, moving stairways, electrical wiring, and
flammable liquid containers. (IPMC 108.1.2)
Inspector: BARRY STRATTON - Comments:
FAIL R3 - Unfit for Human
Occupancy
Is the structure found to be fit for human occupancy according to the code? (IPMC
108.1.3)
Inspector: BARRY STRATTON - Comments: Currently with water running into electric
fixtures it is dangerous to the occupants. Electric shock may occur. Have electrician
check and make electric system safe.
FAIL R5 - Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and
sanitary state? (IPMC 304)
Inspector: BARRY STRATTON - Comments: Roof not installed on house. Roof leaking
into inside on all levels of house. All areas of ceilings & walls that have been damaged
will need removed and replaced. All areas will need water & mold mitigation.
FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair, structurally sound, and in a sanitary condition? (IPMC 305)
Inspector: BARRY STRATTON - Comments: Water damage throughout house from the
roof leaking. Water on every level of house. Water damage in light fixtures. Handrails
needed to upstairs. Porch has water damage from roof leak and windows leaking.
Basement foundation is leaking between house and crawl space.
FAIL R6.A. - Interior Structure-
Unsafe Conditions
Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Inspector: BARRY STRATTON - Comments: Water running out of electric fixtures from
roof leak. Hook Locks on doors on porch will need to be removed.
Printed on 07/24/2020 @ 15:56
Page 2 of 3
GENERAL NOTES
BARRY STRATTON - 06/10/2020 @ 07:43 9-7-4 9-7-5: Need landlord license and rental registration for all rental units in
Waterloo.
REINSPECTION DATE
07/13/2020
CONTACT SIGNATURE
Vieth Reality LLC
Signed on: 06/10/2020 @ 07:45
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on: 06/10/2020 @ 07:45
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319) 231-9147
Printed on 07/24/2020 @ 15:56