HomeMy WebLinkAbout2141 Logan Ave_07132020WATERLOO FIRE RESCUE INSPECTION REPORT 2141 LOGAN AVE, WATERLOO IA 50703 DETAILS Inspection Date: 07/13/2020 | Inspection Type: Rental Inspection | Inspection Number: 4420 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A | Fee: $50.00 STATUS CODE DESCRIPTION FAIL 1031.2 - Reliability Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector: BARRY STRATTON - Comments: Hook locks in use on doors on porch will need removed. FAIL 906.1 - Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B: C. 2. Within 30 feet (9144 mm) of commercial cooking equipment. 3. In areas where flammable or combustible liquids are stored, used or dispensed. 4. On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1. 6. Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON - Comments: Need updated fire extinguisher in unit. FAIL 907.2.11 - Single- and multiple-station smoke alarms Listed single- and multiple- station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY STRATTON - Comments: Smoke detectors are needed in each bedroom, outside of bedrooms & in basement. FAIL R1 - Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either the public or occupants of the structure? (IPMC 108.1.1) Inspector: BARRY STRATTON - Comments: Potential for mold to form from all the water damage in ceiling from roof leaking. Mitigate all water damaged material and replace. Printed on 07/24/2020 @ 16:01 Page 1 of 3 STATUS CODE DESCRIPTION FAIL R3 - Unfit for Human Occupancy Is the structure found to be fit for human occupancy according to the code? (IPMC 108.1.3) Inspector: BARRY STRATTON - Comments: Mold mitigation needed for water damage. FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Inspector: BARRY STRATTON - Comments: Water damage FAIL R6.A. - Interior Structure- Unsafe Conditions Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Inspector: BARRY STRATTON - Comments: Water damage, mold GENERAL NOTES BARRY STRATTON - 07/13/2020 @ 13:41 9-7-4 9-7-5 Need to pay double fee for rental registration at the Clerk's Office since payment was not received prior to the deadline. REINSPECTION DATE 08/10/2020 CONTACT SIGNATURE Vieth Reality LLC Signed on: 07/13/2020 @ 13:42 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 07/13/2020 @ 13:42 Printed on 07/24/2020 @ 16:01 Page 2 of 3 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 16:01 Page 3 of 3