HomeMy WebLinkAbout314 Randolph Street_091219WATERLOO FIRE RESCUE INSPECTION REPORT BLDG 314 RANDOLPH ST, 314 RANDOLPH ST, WATERLOO IA 50701 DETAILS Inspection Date: 09/12/2019 | Inspection Type: Rental Inspection | Inspection Number: 3407 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1008.1 - Means of egress illumination Illumination shall be provided in the means of egress in accordance with Section 1008.2. Under emergency power, means of egress illumination shall comply with Section 1008.3. Inspector: BARRY STRATTON - Comments: All egress lights not working need maintenance FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON - Comments: All egress doors need maintenance. Brock advised owner of items on his report. FAIL 901.6 - Inspection, testing and maintenance Fire detection, alarm, and extinguishing systems, mechanical smoke exhaust systems, and smoke and heat vents shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. Inspector: BARRY STRATTON - Comments: Sprinkler & Alarm report sent to Brock. Egress lights need maintenance. FAIL 903.3.1.1 - NFPA 13 sprinkler systems Where the provisions of this code require that a building or portion thereof be equipped throughout with an automatic sprinkler system in accordance with this section, sprinklers shall be installed throughout in accordance with NFPA 13 except as provided in Sections 903.3.1.1.1 and 903.3.1.1.2. Inspector: BARRY STRATTON - Comments: Sprinkler heads have paint on them that need maintenance by company doing work. FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Printed on 07/24/2020 @ 10:41 Page 1 of 2 STATUS CODE DESCRIPTION Inspector: BARRY STRATTON - Comments: Sanitary efforts door trim, bath floor, kitchen cabinets, holes in walls, paint on sprinkler heads, egress path all need maintenance. Unit # 102 Medicine cabinet in unit # 203 needs replaced. 2nd floor glass above door way needs replaced. Unit #304 Peeling paint, back bedroom ceiling, carpet, door trim, smoke detector taped off, ceiling in living room all items need maintenance. REINSPECTION DATE 10/10/2019 CONTACT SIGNATURE Christin Signed on: 09/12/2019 @ 11:04 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 09/12/2019 @ 11:04 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 10:41 Page 2 of 2