Loading...
HomeMy WebLinkAbout321 Madison St_100819WATERLOO FIRE RESCUE INSPECTION REPORT 321 MADISON ST, WATERLOO IA 50703 DETAILS Inspection Date: 10/08/2019 | Inspection Type: Rental Inspection | Inspection Number: 3551 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 505.1 - Address identification New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) high with a minimum stroke width of 1/2 (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspector: BARRY STRATTON - Comments: Need address listed on Duplex FAIL 605.1 - Abatement of electrical hazards Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON - Comments: Electrical wire on basement bathroom light needs removed or hardwired into switch. Grounding strap on water meter needs secured in approved grounding connectors to water meter. FAIL 907.2.11 - Single- and multiple-station smoke alarms Listed single- and multiple- station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY STRATTON - Comments: Need smoke detectors in bedroom and outside bedroom. FAIL R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) Inspector: BARRY STRATTON - Comments: Need access to water heater. Currently water heater is behind a wall and you can not access water heater. Need 30 inches access to all areas around water heater. Printed on 07/24/2020 @ 13:51 Page 1 of 2 REINSPECTION DATE 11/05/2019 CONTACT SIGNATURE JUANA MARIA MARTINEZ Signed on: 10/08/2019 @ 13:06 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 10/08/2019 @ 13:06 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 13:51 Page 2 of 2