HomeMy WebLinkAbout3921 Midway Dr_02072020WATERLOO FIRE RESCUE INSPECTION REPORT 3921 MIDWAY DR, WATERLOO IA 50701 DETAILS Inspection Date: 02/07/2020 | Inspection Type: Rental Inspection | Inspection Number: 4089 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A | Fee: $50.00 STATUS CODE DESCRIPTION FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON - Comments: Doors shall be maintained in good condition and capable of preforming their intended function. FAIL 1103.9 - Carbon monoxide alarms Existing Group I-1, I-2, I-4 and R occupancies shall be equipped with carbon monoxide alarms in accordance with Section 915, except that the carbon monoxide alarms shall be allowed to be solely battery operated. Inspector: BARRY STRATTON - Comments: FAIL 605.1 - Abatement of electrical hazards Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON - Comments: Outlets not grounded throughout, outlets not working, garage opener running off extension cord. Freezer running off extension cord. Several outlets and switches do not have covers. Open boxes in house with exposed wires. Lights hanging by wires in basement. Water is in light fixture in living room from potential leak from roof. FAIL 906.1 - Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B: C. 2. Within 30 feet (9144 mm) of commercial cooking equipment. 3. In areas where flammable or combustible liquids are stored, used or dispensed. 4. On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1. 6. Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON - Comments: Updated fire extinguisher is needed in unit. Printed on 07/24/2020 @ 15:26 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 907.2.11 - Single- and multiple-station smoke alarms Listed single- and multiple- station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY STRATTON - Comments: Smoke detectors needed in each bedroom, outside bedrooms, and in basement. Smoke detectors have been missing since February 2019 inspection. FAIL 915.4 - Carbon monoxide alarms Carbon monoxide alarms shall comply with Sections 915.4.1 through 915.4.3. Inspector: BARRY STRATTON - Comments: CO detectors are needed in vicinity of the bedrooms. FAIL R1 - Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either the public or occupants of the structure? (IPMC 108.1.1) Inspector: BARRY STRATTON - Comments: FAIL R2 - Unsafe Equipment Was the presence of unsafe equipment noted during the inspection? Equipment may include boilers, heating equipment, elevator, moving stairways, electrical wiring, and flammable liquid containers. (IPMC 108.1.2) Inspector: BARRY STRATTON - Comments: Furnace and water heater plus electric issues. FAIL R3 - Unfit for Human Occupancy Is the structure found to be fit for human occupancy according to the code? (IPMC 108.1.3) Inspector: BARRY STRATTON - Comments: FAIL R4 - Exterior Property Areas Is the exterior property area maintained in a clean, safe, and sanitary condition? This includes grading and drainage, sidewalks and driveways, weeds, and pest infestations. (IPMC 302) Inspector: BARRY STRATTON - Comments: FAIL R5 - Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state? (IPMC 304) Inspector: BARRY STRATTON - Comments: Roof and gutters have not been addressed since February 2019 inspection. Roof and gutters need replaced. FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Printed on 07/24/2020 @ 15:26 Page 2 of 4 STATUS CODE DESCRIPTION Inspector: BARRY STRATTON - Comments: Floors in kitchen and living room need replaced. Water damage in basement from leaking pipes. Potential for mold in basement because of all the moisture present. FAIL R6.A. - Interior Structure- Unsafe Conditions Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Inspector: BARRY STRATTON - Comments: Electricial, water heater draft hood, furnace not working. Water popes leaking in basement. Water damage and exposed wires. FAIL R6.B. - Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F? (IPMC 602.2) Inspector: BARRY STRATTON - Comments: Furnace not working FAIL R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) Inspector: BARRY STRATTON - Comments: Draft hood on water heater not drawing air into hood. Draft hood is not aligned and gives potential for CO gas to discharge into house. Contact licensed contractors to repair water leaks, water heater repairs, and furnace repairs. FAIL R6.D. - Receptacles Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding-type receptacle or a receptacle with a GFCI. Every bathroom shall contain not less than one receptacle. Any new bathroom receptacle shall have GFCI protection. All receptacles shall have the appropriate faceplate cover. (IPMC 605.2) Inspector: BARRY STRATTON - Comments: GENERAL NOTES BARRY STRATTON - 02/07/2020 @ 14:38 9-7-4 9-7-5 Rental registration for 2020 is needed. BARRY STRATTON - 02/07/2020 @ 14:38 9-7-6 A (3) deficiencies have not been corrected since February 2019 Inspection. BARRY STRATTON - 02/07/2020 @ 14:39 304.12 handrails needed on stairway to basement. BARRY STRATTON - 02/07/2020 @ 14:40 IPMC 308 Garbage and debris throughout causing egress paths to be obstructed. Printed on 07/24/2020 @ 15:26 Page 3 of 4 REINSPECTION DATE 03/06/2020 CONTACT SIGNATURE Dustin Arends Signed on: 02/07/2020 @ 14:45 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 02/07/2020 @ 14:44 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 15:26 Page 4 of 4