HomeMy WebLinkAbout411 Whittier Ave_100319WATERLOO FIRE RESCUE INSPECTION REPORT 411 WHITTIER AVE, WATERLOO IA 50703 DETAILS Inspection Date: 10/03/2019 | Inspection Type: Rental Inspection | Inspection Number: 3533 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Inspector: BARRY STRATTON - Comments: Potential mold growing on basement walls from water damage. Spray foam being used to seal cracks. Abatement of mold and seal with mortar instead of spray foam. Bath floor needs replaced. Floor has tiles missing and sub floor has water damage. Toilet needs re-set on floor. Toilet not secure and potential for wax ring to fail. FAIL R6.A. - Interior Structure- Unsafe Conditions Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Inspector: BARRY STRATTON - Comments: Main floor beam in basement has failure. Need to install post(s) to hold main floor from moving/sinking. REINSPECTION DATE 11/04/2019 CONTACT SIGNATURE Kim & Otto Maclin Signed on: 10/03/2019 @ 10:52 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 10/03/2019 @ 10:52 Printed on 07/24/2020 @ 13:49 Page 1 of 2 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 13:49 Page 2 of 2