HomeMy WebLinkAbout416 Sullivan Ave_091219WATERLOO FIRE RESCUE INSPECTION REPORT BLDG 416 SULLIVAN AVE, 416 SULLIVAN AVE, WATERLOO IA 50701 DETAILS Inspection Date: 09/12/2019 | Inspection Type: Rental Inspection | Inspection Number: 3409 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1008.1 - Means of egress illumination Illumination shall be provided in the means of egress in accordance with Section 1008.2. Under emergency power, means of egress illumination shall comply with Section 1008.3. Inspector: BARRY STRATTON - Comments: FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON - Comments: Egress doors shall be maintained. Brock advised owner during inspection FAIL 703.2 - Opening protectives Opening protectives shall be maintained in an operative condition in accordance with NFPA 80. Where allowed by the fire code official, the application of field-applied labels associated with the maintenance of opening protectives shall follow the requirements of the approved third-party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be blocked or obstructed, or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Fire door assemblies shall not be modified. Inspector: BARRY STRATTON - Comments: Egress doors shall be maintained in working condition. FAIL 901.6 - Inspection, testing and maintenance Fire detection, alarm, and extinguishing systems, mechanical smoke exhaust systems, and smoke and heat vents shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. Inspector: BARRY STRATTON - Comments: Information is being given to Brock FAIL 907.2.11 - Single- and multiple-station smoke alarms Listed single- and multiple- station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY STRATTON - Comments: Smoke detector in hallway unit # 307 Printed on 07/24/2020 @ 11:13 Page 1 of 2 STATUS CODE DESCRIPTION FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Inspector: BARRY STRATTON - Comments: Egress lights, dryer vent in laundry room need attached, baluster needs replaced on stairs. Egress doors west end need maintenance. Unit # 103 toilet needs repaired. GENERAL NOTES BARRY STRATTON - 09/12/2019 @ 11:16 Dryer vents need to be attached. IPMC 403.5 REINSPECTION DATE 10/10/2019 CONTACT SIGNATURE Christiin Signed on: 09/12/2019 @ 11:14 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 09/12/2019 @ 11:14 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 11:13 Page 2 of 2