HomeMy WebLinkAbout421 Pine St_02202020WATERLOO FIRE RESCUE INSPECTION REPORT 421 PINE ST, WATERLOO IA 50703 DETAILS Inspection Date: 02/20/2020 | Inspection Type: Rental Inspection | Inspection Number: 4008 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A | Fee: $50.00 STATUS CODE DESCRIPTION FAIL 505.1 - Address identification New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) high with a minimum stroke width of 1/2 (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspector: BARRY STRATTON - Comments: Need apartment identification on all doors. Listed address is classified as a single family owner occupied dwelling not a multiple unit rental dwelling. FAIL 906.1 - Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B: C. 2. Within 30 feet (9144 mm) of commercial cooking equipment. 3. In areas where flammable or combustible liquids are stored, used or dispensed. 4. On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1. 6. Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON - Comments: Need updated fire extinguishers in all units. FAIL 907.2.11 - Single- and multiple-station smoke alarms Listed single- and multiple- station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY STRATTON - Comments: Smoke detectors are needed in all units installed to meet code requirements. Printed on 07/24/2020 @ 15:29 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 915.4 - Carbon monoxide alarms Carbon monoxide alarms shall comply with Sections 915.4.1 through 915.4.3. Inspector: BARRY STRATTON - Comments: CO detectors need installed to meet code requirements. FAIL R2 - Unsafe Equipment Was the presence of unsafe equipment noted during the inspection? Equipment may include boilers, heating equipment, elevator, moving stairways, electrical wiring, and flammable liquid containers. (IPMC 108.1.2) Inspector: BARRY STRATTON - Comments: No heat and no water reported by tenants. FAIL R3 - Unfit for Human Occupancy Is the structure found to be fit for human occupancy according to the code? (IPMC 108.1.3) Inspector: BARRY STRATTON - Comments: Occupancy is contingent on building having heat and water. FAIL R4 - Exterior Property Areas Is the exterior property area maintained in a clean, safe, and sanitary condition? This includes grading and drainage, sidewalks and driveways, weeds, and pest infestations. (IPMC 302) Inspector: BARRY STRATTON - Comments: FAIL R6.A. - Interior Structure- Unsafe Conditions Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Inspector: BARRY STRATTON - Comments: Tenants reported no heat and no water. FAIL R6.B. - Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F? (IPMC 602.2) Inspector: BARRY STRATTON - Comments: FAIL R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) Inspector: BARRY STRATTON - Comments: All fuel-burning and water heating appliances shall be properly installed and maintained in a sage working condition. GENERAL NOTES Printed on 07/24/2020 @ 15:29 Page 2 of 3 BARRY STRATTON - 02/20/2020 @ 09:51 9-7-4 9-7-5: 2020 Rental registration is needed for all units. Property will need multi unit designation. BARRY STRATTON - 02/20/2020 @ 09:52 9-7-6 A (3) Failure to correct deficiencies shall result in a municipal citation(s) being issued. REINSPECTION DATE 03/19/2020 CONTACT SIGNATURE Mark Marquand Marty & Collette Marquand Signed on: 02/20/2020 @ 09:53 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 02/20/2020 @ 09:53 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 15:29 Page 3 of 3