INSPECTION REPORT
508 LOGAN AVE, WATERLOO IA 50703
DETAILS
Inspection Date: 09/12/2019 | Inspection Type: Rental Inspection | Inspection Number: 3395 | Shift: N/A | Station: N/A |
Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A
STATUS CODE DESCRIPTION
FAIL 1103.9 - Carbon monoxide
alarms
Existing Group I-1, I-2, I-4 and R occupancies shall be equipped with carbon monoxide
alarms in accordance with Section 915, except that the carbon monoxide alarms shall
be allowed to be solely battery operated.
Inspector: BARRY STRATTON - Comments: CO detector is needed in vicinity of the
bedrooms.
FAIL 1104.13 - Stairway handrails Stairways shall have handrails on at least one side. Handrails shall be located so that
all portions of the stairway width required for egress capacity are within 44 inches
(1118 mm) of a handrail. Exception: Aisle stairs provided with a center handrail are
not required to have additional handrails.
Inspector: BARRY STRATTON - Comments: Need handrails installed on basement
stairs.
FAIL 605.1 - Abatement of
electrical hazards
Identified electrical hazards shall be abated. Identified hazardous electrical conditions
in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON - Comments: Need globes on all light fixtures. Bathroom
light needs cover and bulbs.
FAIL 907.2.11 - Single- and
multiple-station smoke
alarms
Listed single- and multiple- station smoke alarms complying with UL 217 shall be
installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
Inspector: BARRY STRATTON - Comments: Smoke detectors are needed in each
bedroom, outside of the bedrooms, and in basement.
FAIL R1 - Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either
the public or occupants of the structure? (IPMC 108.1.1)
Inspector: BARRY STRATTON - Comments: Garage
Printed on 07/24/2020 @ 11:21
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL R4 - Exterior Property Areas Is the exterior property area maintained in a clean, safe, and sanitary condition? This
includes grading and drainage, sidewalks and driveways, weeds, and pest
infestations. (IPMC 302)
Inspector: BARRY STRATTON - Comments:
FAIL R5 - Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and
sanitary state? (IPMC 304)
Inspector: BARRY STRATTON - Comments: Garage will need repaired. Roof, sofit, and
boards rotten on garage.
FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair, structurally sound, and in a sanitary condition? (IPMC 305)
Inspector: BARRY STRATTON - Comments: Water heater no permits/inspections for
installation
FAIL R6.A. - Interior Structure-
Unsafe Conditions
Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Inspector: BARRY STRATTON - Comments: Kitchen cabinets need repaired. Doors
falling off hinges. Holes in floors need repaired. Repair holes in floor. Windows in
living room needs repaired/replaced since window will not secure in frame. Window
in bathroom the frame/sill is rotten and needs replaced.
FAIL R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition? (IPMC 603.1)
Inspector: BARRY STRATTON - Comments: Water heater installed with out permits.
Supply lines not installed to code. Contact licensed plumber to obtain permits and
inspections. Have contractor install water heater to code.
GENERAL NOTES
BARRY STRATTON - 09/12/2019 @ 09:04 Sanitary sewer leaking in basement. Upstairs toilet needs re-set. Floor under bathroom
in basement wet. IPMC 504
BARRY STRATTON - 09/12/2019 @ 09:04 Have plumbing checked so correct leak onto basement floor. IPMC 504
BARRY STRATTON - 09/12/2019 @ 09:05 Mice infestation in unit. Infestation needs mitigated. IPMC 309
Printed on 07/24/2020 @ 11:21
Page 2 of 3
GENERAL NOTES
BARRY STRATTON - 09/12/2019 @ 09:09 Screen door on front of house needs repaired. Need door hardware installed on door.
Door does not latch. IPMC 304.15
REINSPECTION DATE
10/11/2019
CONTACT SIGNATURE
Richard Kaough
Signed on: 09/12/2019 @ 09:13
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on: 09/12/2019 @ 09:13