HomeMy WebLinkAbout537 Independence Ave_101419WATERLOO FIRE RESCUE INSPECTION REPORT 537 INDEPENDENCE AVE, WATERLOO IA 50703 DETAILS Inspection Date: 10/14/2019 | Inspection Type: Rental Inspection | Inspection Number: 3428 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A | Fee: $50.00 STATUS CODE DESCRIPTION FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON - Comments: Egress path has obstruction at front door on porch area. All doors shall be functional and all hardware maintained in good condition. Rear door & jamb is busted and needs replaced. Trim is missing on some doors and needs replaced. hardware shall be capable of locking and latching doors. FAIL 1103.9 - Carbon monoxide alarms Existing Group I-1, I-2, I-4 and R occupancies shall be equipped with carbon monoxide alarms in accordance with Section 915, except that the carbon monoxide alarms shall be allowed to be solely battery operated. Inspector: BARRY STRATTON - Comments: Need CO detectors in vicinity of the bedrooms. FAIL 605.1 - Abatement of electrical hazards Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON - Comments: Globes are required on all light fixtures. All electric outlets and switches will need to be in working condition. FAIL 907.2.11 - Single- and multiple-station smoke alarms Listed single- and multiple- station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY STRATTON - Comments: Smoke detectors needed to be installed to meet code. In each bedroom, outside of the bedrooms, and in basement. FAIL 915.4 - Carbon monoxide alarms Carbon monoxide alarms shall comply with Sections 915.4.1 through 915.4.3. Inspector: BARRY STRATTON - Comments: Printed on 07/24/2020 @ 13:54 Page 1 of 3 STATUS CODE DESCRIPTION FAIL R1 - Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either the public or occupants of the structure? (IPMC 108.1.1) Inspector: BARRY STRATTON - Comments: Open electrical wires in basement. Mold present in basement from wall being damaged by water. Mold exposure is dangerous and this unit has potential for mold to be unsafe for the occupants. FAIL R2 - Unsafe Equipment Was the presence of unsafe equipment noted during the inspection? Equipment may include boilers, heating equipment, elevator, moving stairways, electrical wiring, and flammable liquid containers. (IPMC 108.1.2) Inspector: BARRY STRATTON - Comments: Furnace and water heater will need repaired by licensed contractor. FAIL R4 - Exterior Property Areas Is the exterior property area maintained in a clean, safe, and sanitary condition? This includes grading and drainage, sidewalks and driveways, weeds, and pest infestations. (IPMC 302) Inspector: BARRY STRATTON - Comments: FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Inspector: BARRY STRATTON - Comments: Potential mold in basement from leak in plumbing & kitchen sink leaking into basement. Mold needs mitigated. All holes in walls need repaired. Stair treads to basement shall be maintained in good and sanitary condition. Handrails need to be installed. FAIL R6.A. - Interior Structure- Unsafe Conditions Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Inspector: BARRY STRATTON - Comments: Need handrails to basement and correct open electric wires in basement. FAIL R6.B. - Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F? (IPMC 602.2) Inspector: BARRY STRATTON - Comments: Furnace does not work and will need repaired?replaced. FAIL R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) Inspector: BARRY STRATTON - Comments: Discharge tube on water heater in not installed to meet code. Draft hood and flue not correct for this water heater. Printed on 07/24/2020 @ 13:54 Page 2 of 3 GENERAL NOTES BARRY STRATTON - 10/14/2019 @ 10:16 AN exhaust fan shall be installed in bathroom. IPMC 403.2 BARRY STRATTON - 10/14/2019 @ 10:17 Plumbing leak in basement. All fixtures shall be installed and maintained in working condition. IPMC 504 REINSPECTION DATE 11/13/2019 CONTACT SIGNATURE Shane & Julious Green Signed on: 10/14/2019 @ 10:17 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 10/14/2019 @ 10:17 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 13:54 Page 3 of 3