HomeMy WebLinkAbout544 Archer Ave_103119WATERLOO FIRE RESCUE
INSPECTION REPORT
544 ARCHER AVE, WATERLOO IA 50703
DETAILS
Inspection Date: 10/31/2019 | Inspection Type: Rental Inspection | Inspection Number: 3664 | Shift: N/A | Station: N/A |
Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A | Fee: $50.00
STATUS CODE DESCRIPTION
FAIL 505.1 - Address identification New and existing buildings shall be provided with approved address identification.
The address identification shall be legible and placed in a position that is visible from
the street or road fronting the property. Address identification characters shall
contrast with their background. Address numbers shall be Arabic numbers or
alphabetical letters. Numbers shall not be spelled out. Each character shall be not
less than 4 inches (102 mm) high with a minimum stroke width of 1/2 (12.7 mm).
Where required by the fire code official, address identification shall be provided in
additional approved locations to facilitate emergency response. Where access is by
means of a private road and the building cannot be viewed from the public way, a
monument, pole or other sign or means shall be used to identify the structure.
Address identification shall be maintained.
Inspector: BARRY STRATTON - Comments: Address need to contrast to the house.
Numbers are faded and can not be seen very well from street.
FAIL 605.1 - Abatement of
electrical hazards
Identified electrical hazards shall be abated. Identified hazardous electrical conditions
in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON - Comments: Bath fan installed without permits and does
not exhaust to the exterior. Need egress light in hallway at back door to basement.
FAIL 907.2.11 - Single- and
multiple-station smoke
alarms
Listed single- and multiple- station smoke alarms complying with UL 217 shall be
installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
Inspector: BARRY STRATTON - Comments: Smoke detectors needed outside of the
bedrooms, in each bedroom and in basement.
FAIL 915.4 - Carbon monoxide
alarms
Carbon monoxide alarms shall comply with Sections 915.4.1 through 915.4.3.
Inspector: BARRY STRATTON - Comments: CO detectors are required to be installed in
vicinity of the bedrooms.
Printed on 07/24/2020 @ 14:20
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL R2 - Unsafe Equipment Was the presence of unsafe equipment noted during the inspection? Equipment may
include boilers, heating equipment, elevator, moving stairways, electrical wiring, and
flammable liquid containers. (IPMC 108.1.2)
Inspector: BARRY STRATTON - Comments: Stove/gas smell
FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair, structurally sound, and in a sanitary condition? (IPMC 305)
Inspector: BARRY STRATTON - Comments: Potential for mold to form in bathroom. All
areas shall be maintained in a clean and sanitary condition. Water in basement.
Sewer drain stack not supported per code and leaking. Electric tape is not a approved
method for stopping leaks. Need to chalk tub surround. Mice feces in basement.
Screen door on front door needs new hardware so door can close and latch.
FAIL R6.A. - Interior Structure-
Unsafe Conditions
Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Inspector: BARRY STRATTON - Comments: Stove needs checked. Gas coming from
stove when it ignites. Possible bad valve. Potential for carbon monoxide poisoning.
FAIL R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition? (IPMC 603.1)
Inspector: BARRY STRATTON - Comments: Water heater supply line are not installed
to meet code. PEX lines used to the top of a gas water heater. Have licensed
contractor correct water heater to meed code.
GENERAL NOTES
BARRY STRATTON - 10/31/2019 @ 10:54 Basement window is broken and needs replaced. IPMC 304.13
BARRY STRATTON - 10/31/2019 @ 10:55 Drain stack in basement needs to be supported and not leak. IPMC 504
BARRY STRATTON - 10/31/2019 @ 10:55 9-7-4 9-7-5 Rental registration is needed. Unit currently is not registered.
BARRY STRATTON - 10/31/2019 @ 10:57 Back door entry way needs light to illuminate area at entryway to basement. IPMC
605.3
Printed on 07/24/2020 @ 14:20
Page 2 of 3
REINSPECTION DATE
12/02/2019
CONTACT SIGNATURE
Dorothy Haugebak
Signed on: 10/31/2019 @ 10:58
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on: 10/31/2019 @ 10:58