STATUS CODE DESCRIPTION
FAIL 605.1 - Abatement of
electrical hazards
Identified electrical hazards shall be abated. Identified hazardous electrical conditions
in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON - Comments: Outlets in upstairs front bedroom are not
grounded.
FAIL 907.2.11 - Single- and
multiple-station smoke
alarms
Listed single- and multiple- station smoke alarms complying with UL 217 shall be
installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
Inspector: BARRY STRATTON - Comments: Smoke detector in dining room not
working.
FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair, structurally sound, and in a sanitary condition? (IPMC 305)
Inspector: BARRY STRATTON - Comments: Sewer stack in basement needs cap on
clean out. Currently washing machine drain is draining in clean out. Potential for
sewer gas to leak from area.
FAIL R6.D. - Receptacles Every habitable space in a dwelling shall contain not less than two separate and
remote receptacle outlets. Every laundry area shall contain not less than one
grounding-type receptacle or a receptacle with a GFCI. Every bathroom shall contain
not less than one receptacle. Any new bathroom receptacle shall have GFCI
protection. All receptacles shall have the appropriate faceplate cover. (IPMC 605.2)
Inspector: BARRY STRATTON - Comments:
REINSPECTION DATE
10/17/2019
Printed on 07/24/2020 @ 11:23
Page 1 of 2
CONTACT SIGNATURE
Kaleen Hanson
Signed on: 09/17/2019 @ 14:15
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on: 09/17/2019 @ 14:14
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319) 231-9147
Printed on 07/24/2020 @ 11:23
Page 2 of 2