HomeMy WebLinkAbout601 Ricker St_07142020WATERLOO FIRE RESCUE INSPECTION REPORT 601 RICKER ST, WATERLOO IA 50703 DETAILS Inspection Date: 07/14/2020 | Inspection Type: Rental Inspection | Inspection Number: 4554 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON - Comments: Front door and jamb needs replaced. Door busted and jamb broken. FAIL 5704.2.13.2.3 - Out of service for one year Above-ground tanks that have been out of service for a period of one year shall be removed in accordance with Section 5704.2.14. Exception: Tanks within operating facilities. Inspector: BARRY STRATTON - Comments: Fuel tank and fill tubes/vents will need removed from basement. FAIL 605.1 - Abatement of electrical hazards Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON - Comments: Open electric wires in basement ceiling. Electric outlets not working in basement. FAIL 907.2.11 - Single- and multiple-station smoke alarms Listed single- and multiple- station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY STRATTON - Comments: Need smoke detectors in each bedroom and in basement. All smoke detectors shall be in working condition. FAIL R2 - Unsafe Equipment Was the presence of unsafe equipment noted during the inspection? Equipment may include boilers, heating equipment, elevator, moving stairways, electrical wiring, and flammable liquid containers. (IPMC 108.1.2) Inspector: BARRY STRATTON - Comments: Discharge tube missing on water heater. Printed on 07/24/2020 @ 16:06 Page 1 of 2 STATUS CODE DESCRIPTION FAIL R5 - Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state? (IPMC 304) Inspector: BARRY STRATTON - Comments: Windows and window sills FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Inspector: BARRY STRATTON - Comments: Water leaking into basement needs corrected. Need handrails to basement. Sink in bathroom not draining. Tub leaking into basement. Windows need to be capable of opening and closing. Broken windows needs replaced. Front step needs repaired. Rotten window sills need repaired. Fuel tank and fill tubes/vents need removed from basement. FAIL R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) Inspector: BARRY STRATTON - Comments: Water heater missing discharge tube. REINSPECTION DATE 08/11/2020 CONTACT SIGNATURE Beth Smith Signed on: 07/14/2020 @ 14:43 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 07/14/2020 @ 14:44 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 16:06 Page 2 of 2