Loading...
HomeMy WebLinkAbout617 Boston Ave_011620WATERLOO FIRE RESCUE INSPECTION REPORT 617 BOSTON AVE, WATERLOO IA 50703 DETAILS Inspection Date: 01/16/2020 | Inspection Type: Rental Inspection | Inspection Number: 3968 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 505.1 - Address identification New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) high with a minimum stroke width of 1/2 (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspector: BARRY STRATTON - Comments: Need address posted on front of house. FAIL 907.2.11 - Single- and multiple-station smoke alarms Listed single- and multiple- station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY STRATTON - Comments: Need smoke detectors in each bedroom, outside of the bedrooms, and in basement. FAIL 915.4 - Carbon monoxide alarms Carbon monoxide alarms shall comply with Sections 915.4.1 through 915.4.3. Inspector: BARRY STRATTON - Comments: CO detectors needed in vicinity of the bedrooms. FAIL R3 - Unfit for Human Occupancy Is the structure found to be fit for human occupancy according to the code? (IPMC 108.1.3) Inspector: BARRY STRATTON - Comments: Raw sewage backup in basement. FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Printed on 07/24/2020 @ 15:17 Page 1 of 2 STATUS CODE DESCRIPTION Inspector: BARRY STRATTON - Comments: Sewer backed up in basement. Bathroom sink and bathtub not draining. All fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks, and defects and be capable of performing the function for which fixtures are designed. Where it is found that a system in a structure constitutes a hazard to the occupants the defect shall be corrected. FAIL R6.A. - Interior Structure- Unsafe Conditions Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Inspector: BARRY STRATTON - Comments: Raw sewage in basement. FAIL R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) Inspector: BARRY STRATTON - Comments: Sewer back up in basement can affect water heater & furnace operation. Check equipment to ensure they are functioning to manufactures specifications. REINSPECTION DATE 02/17/2020 CONTACT SIGNATURE Cedarloo Rentals LLC Signed on: 01/16/2020 @ 12:50 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 01/16/2020 @ 12:50 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 15:17 Page 2 of 2